Cargando…
Actigraphy-based sleep estimation in adolescents and adults: a comparison with polysomnography using two scoring algorithms
OBJECTIVES: Actigraphy is widely used to estimate sleep–wake time, despite limited information regarding the comparability of different devices and algorithms. We compared estimates of sleep–wake times determined by two wrist actigraphs (GT3X+ versus Actiwatch Spectrum [AWS]) to in-home polysomnogra...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Dove Medical Press
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5779275/ https://www.ncbi.nlm.nih.gov/pubmed/29403321 http://dx.doi.org/10.2147/NSS.S151085 |
_version_ | 1783294501561827328 |
---|---|
author | Quante, Mirja Kaplan, Emily R Cailler, Michael Rueschman, Michael Wang, Rui Weng, Jia Taveras, Elsie M Redline, Susan |
author_facet | Quante, Mirja Kaplan, Emily R Cailler, Michael Rueschman, Michael Wang, Rui Weng, Jia Taveras, Elsie M Redline, Susan |
author_sort | Quante, Mirja |
collection | PubMed |
description | OBJECTIVES: Actigraphy is widely used to estimate sleep–wake time, despite limited information regarding the comparability of different devices and algorithms. We compared estimates of sleep–wake times determined by two wrist actigraphs (GT3X+ versus Actiwatch Spectrum [AWS]) to in-home polysomnography (PSG), using two algorithms (Sadeh and Cole–Kripke) for the GT3X+ recordings. SUBJECTS AND METHODS: Participants included a sample of 35 healthy volunteers (13 school children and 22 adults, 46% male) from Boston, MA, USA. Twenty-two adults wore the GT3X+ and AWS simultaneously for at least five consecutive days and nights. In addition, actigraphy and PSG were concurrently measured in 12 of these adults and another 13 children over a single night. We used intraclass correlation coefficients (ICCs), epoch-by-epoch comparisons, paired t-tests, and Bland–Altman plots to determine the level of agreement between actigraphy and PSG, and differences between devices and algorithms. RESULTS: Each actigraph showed comparable accuracy (0.81–0.86) for sleep–wake estimation compared to PSG. When analyzing data from the GT3X+, the Cole–Kripke algorithm was more sensitive (0.88–0.96) to detect sleep, but less specific (0.35–0.64) to detect wake than the Sadeh algorithm (sensitivity: 0.82–0.91, specificity: 0.47–0.68). Total sleep time measured using the GT3X+ with both algorithms was similar to that obtained by PSG (ICC=0.64–0.88). In contrast, agreement between the GT3X+ and PSG wake after sleep onset was poor (ICC=0.00–0.10). In adults, the GT3X+ using the Cole–Kripke algorithm provided data comparable to the AWS (mean bias=3.7±19.7 minutes for total sleep time and 8.0±14.2 minutes for wake after sleep onset). CONCLUSION: The two actigraphs provided comparable and accurate data compared to PSG, although both poorly identified wake episodes (i.e., had low specificity). Use of actigraphy scoring algorithm influenced the mean bias and level of agreement in sleep–wake times estimates. The GT3X+, when analyzed by the Cole–Kripke, but not the Sadeh algorithm, provided comparable data to the AWS. |
format | Online Article Text |
id | pubmed-5779275 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | Dove Medical Press |
record_format | MEDLINE/PubMed |
spelling | pubmed-57792752018-02-05 Actigraphy-based sleep estimation in adolescents and adults: a comparison with polysomnography using two scoring algorithms Quante, Mirja Kaplan, Emily R Cailler, Michael Rueschman, Michael Wang, Rui Weng, Jia Taveras, Elsie M Redline, Susan Nat Sci Sleep Original Research OBJECTIVES: Actigraphy is widely used to estimate sleep–wake time, despite limited information regarding the comparability of different devices and algorithms. We compared estimates of sleep–wake times determined by two wrist actigraphs (GT3X+ versus Actiwatch Spectrum [AWS]) to in-home polysomnography (PSG), using two algorithms (Sadeh and Cole–Kripke) for the GT3X+ recordings. SUBJECTS AND METHODS: Participants included a sample of 35 healthy volunteers (13 school children and 22 adults, 46% male) from Boston, MA, USA. Twenty-two adults wore the GT3X+ and AWS simultaneously for at least five consecutive days and nights. In addition, actigraphy and PSG were concurrently measured in 12 of these adults and another 13 children over a single night. We used intraclass correlation coefficients (ICCs), epoch-by-epoch comparisons, paired t-tests, and Bland–Altman plots to determine the level of agreement between actigraphy and PSG, and differences between devices and algorithms. RESULTS: Each actigraph showed comparable accuracy (0.81–0.86) for sleep–wake estimation compared to PSG. When analyzing data from the GT3X+, the Cole–Kripke algorithm was more sensitive (0.88–0.96) to detect sleep, but less specific (0.35–0.64) to detect wake than the Sadeh algorithm (sensitivity: 0.82–0.91, specificity: 0.47–0.68). Total sleep time measured using the GT3X+ with both algorithms was similar to that obtained by PSG (ICC=0.64–0.88). In contrast, agreement between the GT3X+ and PSG wake after sleep onset was poor (ICC=0.00–0.10). In adults, the GT3X+ using the Cole–Kripke algorithm provided data comparable to the AWS (mean bias=3.7±19.7 minutes for total sleep time and 8.0±14.2 minutes for wake after sleep onset). CONCLUSION: The two actigraphs provided comparable and accurate data compared to PSG, although both poorly identified wake episodes (i.e., had low specificity). Use of actigraphy scoring algorithm influenced the mean bias and level of agreement in sleep–wake times estimates. The GT3X+, when analyzed by the Cole–Kripke, but not the Sadeh algorithm, provided comparable data to the AWS. Dove Medical Press 2018-01-18 /pmc/articles/PMC5779275/ /pubmed/29403321 http://dx.doi.org/10.2147/NSS.S151085 Text en © 2018 Quante et al. This work is published and licensed by Dove Medical Press Limited The full terms of this license are available at https://www.dovepress.com/terms.php and incorporate the Creative Commons Attribution – Non Commercial (unported, v3.0) License (http://creativecommons.org/licenses/by-nc/3.0/). By accessing the work you hereby accept the Terms. Non-commercial uses of the work are permitted without any further permission from Dove Medical Press Limited, provided the work is properly attributed. |
spellingShingle | Original Research Quante, Mirja Kaplan, Emily R Cailler, Michael Rueschman, Michael Wang, Rui Weng, Jia Taveras, Elsie M Redline, Susan Actigraphy-based sleep estimation in adolescents and adults: a comparison with polysomnography using two scoring algorithms |
title | Actigraphy-based sleep estimation in adolescents and adults: a comparison with polysomnography using two scoring algorithms |
title_full | Actigraphy-based sleep estimation in adolescents and adults: a comparison with polysomnography using two scoring algorithms |
title_fullStr | Actigraphy-based sleep estimation in adolescents and adults: a comparison with polysomnography using two scoring algorithms |
title_full_unstemmed | Actigraphy-based sleep estimation in adolescents and adults: a comparison with polysomnography using two scoring algorithms |
title_short | Actigraphy-based sleep estimation in adolescents and adults: a comparison with polysomnography using two scoring algorithms |
title_sort | actigraphy-based sleep estimation in adolescents and adults: a comparison with polysomnography using two scoring algorithms |
topic | Original Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5779275/ https://www.ncbi.nlm.nih.gov/pubmed/29403321 http://dx.doi.org/10.2147/NSS.S151085 |
work_keys_str_mv | AT quantemirja actigraphybasedsleepestimationinadolescentsandadultsacomparisonwithpolysomnographyusingtwoscoringalgorithms AT kaplanemilyr actigraphybasedsleepestimationinadolescentsandadultsacomparisonwithpolysomnographyusingtwoscoringalgorithms AT caillermichael actigraphybasedsleepestimationinadolescentsandadultsacomparisonwithpolysomnographyusingtwoscoringalgorithms AT rueschmanmichael actigraphybasedsleepestimationinadolescentsandadultsacomparisonwithpolysomnographyusingtwoscoringalgorithms AT wangrui actigraphybasedsleepestimationinadolescentsandadultsacomparisonwithpolysomnographyusingtwoscoringalgorithms AT wengjia actigraphybasedsleepestimationinadolescentsandadultsacomparisonwithpolysomnographyusingtwoscoringalgorithms AT taveraselsiem actigraphybasedsleepestimationinadolescentsandadultsacomparisonwithpolysomnographyusingtwoscoringalgorithms AT redlinesusan actigraphybasedsleepestimationinadolescentsandadultsacomparisonwithpolysomnographyusingtwoscoringalgorithms |