Steady state visual evoked potential (SSVEP) based brain-computer interface (BCI) performance under different perturbations

Brain-computer interface (BCI) paradigms are usually tested when environmental and biological artifacts are intentionally avoided. In this study, we deliberately introduced different perturbations in order to test the robustness of a steady state visual evoked potential (SSVEP) based BCI. Specifical...

Descripción completa

Detalles Bibliográficos
Autores principales: İşcan, Zafer, Nikulin, Vadim V.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5779700/
https://www.ncbi.nlm.nih.gov/pubmed/29360843
http://dx.doi.org/10.1371/journal.pone.0191673
_version_ 1783294591286378496
author İşcan, Zafer
Nikulin, Vadim V.
author_facet İşcan, Zafer
Nikulin, Vadim V.
author_sort İşcan, Zafer
collection PubMed
description Brain-computer interface (BCI) paradigms are usually tested when environmental and biological artifacts are intentionally avoided. In this study, we deliberately introduced different perturbations in order to test the robustness of a steady state visual evoked potential (SSVEP) based BCI. Specifically we investigated to what extent a drop in performance is related to the degraded quality of EEG signals or rather due to increased cognitive load. In the online tasks, subjects focused on one of the four circles and gave feedback on the correctness of the classification under four conditions randomized across subjects: Control (no perturbation), Speaking (counting loudly and repeatedly from one to ten), Thinking (mentally counting repeatedly from one to ten), and Listening (listening to verbal counting from one to ten). Decision tree, Naïve Bayes and K-Nearest Neighbor classifiers were used to evaluate the classification performance using features generated by canonical correlation analysis. During the online condition, Speaking and Thinking decreased moderately the mean classification accuracy compared to Control condition whereas there was no significant difference between Listening and Control conditions across subjects. The performances were sensitive to the classification method and to the perturbation conditions. We have not observed significant artifacts in EEG during perturbations in the frequency range of interest except in theta band. Therefore we concluded that the drop in the performance is likely to have a cognitive origin. During the Listening condition relative alpha power in a broad area including central and temporal regions primarily over the left hemisphere correlated negatively with the performance thus most likely indicating active suppression of the distracting presentation of the playback. This is the first study that systematically evaluates the effects of natural artifacts (i.e. mental, verbal and audio perturbations) on SSVEP-based BCIs. The results can be used to improve individual classification performance taking into account effects of perturbations.
format Online
Article
Text
id pubmed-5779700
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-57797002018-02-08 Steady state visual evoked potential (SSVEP) based brain-computer interface (BCI) performance under different perturbations İşcan, Zafer Nikulin, Vadim V. PLoS One Research Article Brain-computer interface (BCI) paradigms are usually tested when environmental and biological artifacts are intentionally avoided. In this study, we deliberately introduced different perturbations in order to test the robustness of a steady state visual evoked potential (SSVEP) based BCI. Specifically we investigated to what extent a drop in performance is related to the degraded quality of EEG signals or rather due to increased cognitive load. In the online tasks, subjects focused on one of the four circles and gave feedback on the correctness of the classification under four conditions randomized across subjects: Control (no perturbation), Speaking (counting loudly and repeatedly from one to ten), Thinking (mentally counting repeatedly from one to ten), and Listening (listening to verbal counting from one to ten). Decision tree, Naïve Bayes and K-Nearest Neighbor classifiers were used to evaluate the classification performance using features generated by canonical correlation analysis. During the online condition, Speaking and Thinking decreased moderately the mean classification accuracy compared to Control condition whereas there was no significant difference between Listening and Control conditions across subjects. The performances were sensitive to the classification method and to the perturbation conditions. We have not observed significant artifacts in EEG during perturbations in the frequency range of interest except in theta band. Therefore we concluded that the drop in the performance is likely to have a cognitive origin. During the Listening condition relative alpha power in a broad area including central and temporal regions primarily over the left hemisphere correlated negatively with the performance thus most likely indicating active suppression of the distracting presentation of the playback. This is the first study that systematically evaluates the effects of natural artifacts (i.e. mental, verbal and audio perturbations) on SSVEP-based BCIs. The results can be used to improve individual classification performance taking into account effects of perturbations. Public Library of Science 2018-01-23 /pmc/articles/PMC5779700/ /pubmed/29360843 http://dx.doi.org/10.1371/journal.pone.0191673 Text en © 2018 İşcan, Nikulin http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Research Article
İşcan, Zafer
Nikulin, Vadim V.
Steady state visual evoked potential (SSVEP) based brain-computer interface (BCI) performance under different perturbations
title Steady state visual evoked potential (SSVEP) based brain-computer interface (BCI) performance under different perturbations
title_full Steady state visual evoked potential (SSVEP) based brain-computer interface (BCI) performance under different perturbations
title_fullStr Steady state visual evoked potential (SSVEP) based brain-computer interface (BCI) performance under different perturbations
title_full_unstemmed Steady state visual evoked potential (SSVEP) based brain-computer interface (BCI) performance under different perturbations
title_short Steady state visual evoked potential (SSVEP) based brain-computer interface (BCI) performance under different perturbations
title_sort steady state visual evoked potential (ssvep) based brain-computer interface (bci) performance under different perturbations
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5779700/
https://www.ncbi.nlm.nih.gov/pubmed/29360843
http://dx.doi.org/10.1371/journal.pone.0191673
work_keys_str_mv AT iscanzafer steadystatevisualevokedpotentialssvepbasedbraincomputerinterfacebciperformanceunderdifferentperturbations
AT nikulinvadimv steadystatevisualevokedpotentialssvepbasedbraincomputerinterfacebciperformanceunderdifferentperturbations