Cargando…

Periorbital Biometric Measurements using ImageJ Software: Standardisation of Technique and Assessment Of Intra- and Interobserver Variability

PURPOSE: To assess the reliability and repeatability of periorbital biometric measurements using ImageJ software and to assess if the horizontal visible iris diameter (HVID) serves as a reliable scale for facial measurements. METHODS: This study was a prospective, single-blind, comparative study. Tw...

Descripción completa

Detalles Bibliográficos
Autores principales: Rajyalakshmi, R., Prakash, Winston D., Ali, Mohammad Javed, Naik, Milind N.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Medknow Publications & Media Pvt Ltd 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5782436/
https://www.ncbi.nlm.nih.gov/pubmed/29403183
http://dx.doi.org/10.4103/JCAS.JCAS_61_17
_version_ 1783295193023250432
author Rajyalakshmi, R.
Prakash, Winston D.
Ali, Mohammad Javed
Naik, Milind N.
author_facet Rajyalakshmi, R.
Prakash, Winston D.
Ali, Mohammad Javed
Naik, Milind N.
author_sort Rajyalakshmi, R.
collection PubMed
description PURPOSE: To assess the reliability and repeatability of periorbital biometric measurements using ImageJ software and to assess if the horizontal visible iris diameter (HVID) serves as a reliable scale for facial measurements. METHODS: This study was a prospective, single-blind, comparative study. Two clinicians performed 12 periorbital measurements on 100 standardised face photographs. Each individual’s HVID was determined by Orbscan IIz and used as a scale for measurements using ImageJ software. All measurements were repeated using the ‘average’ HVID of the study population as a measurement scale. Intraclass correlation coefficient (ICC) and Pearson product-moment coefficient were used as statistical tests to analyse the data. RESULTS: The range of ICC for intra- and interobserver variability was 0.79–0.99 and 0.86–0.99, respectively. Test-retest reliability ranged from 0.66–1.0 to 0.77–0.98, respectively. When average HVID of the study population was used as scale, ICC ranged from 0.83 to 0.99, and the test-retest reliability ranged from 0.83 to 0.96 and the measurements correlated well with recordings done with individual Orbscan HVID measurements. CONCLUSION: Periorbital biometric measurements using ImageJ software are reproducible and repeatable. Average HVID of the population as measured by Orbscan is a reliable scale for facial measurements.
format Online
Article
Text
id pubmed-5782436
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher Medknow Publications & Media Pvt Ltd
record_format MEDLINE/PubMed
spelling pubmed-57824362018-02-05 Periorbital Biometric Measurements using ImageJ Software: Standardisation of Technique and Assessment Of Intra- and Interobserver Variability Rajyalakshmi, R. Prakash, Winston D. Ali, Mohammad Javed Naik, Milind N. J Cutan Aesthet Surg Original Article PURPOSE: To assess the reliability and repeatability of periorbital biometric measurements using ImageJ software and to assess if the horizontal visible iris diameter (HVID) serves as a reliable scale for facial measurements. METHODS: This study was a prospective, single-blind, comparative study. Two clinicians performed 12 periorbital measurements on 100 standardised face photographs. Each individual’s HVID was determined by Orbscan IIz and used as a scale for measurements using ImageJ software. All measurements were repeated using the ‘average’ HVID of the study population as a measurement scale. Intraclass correlation coefficient (ICC) and Pearson product-moment coefficient were used as statistical tests to analyse the data. RESULTS: The range of ICC for intra- and interobserver variability was 0.79–0.99 and 0.86–0.99, respectively. Test-retest reliability ranged from 0.66–1.0 to 0.77–0.98, respectively. When average HVID of the study population was used as scale, ICC ranged from 0.83 to 0.99, and the test-retest reliability ranged from 0.83 to 0.96 and the measurements correlated well with recordings done with individual Orbscan HVID measurements. CONCLUSION: Periorbital biometric measurements using ImageJ software are reproducible and repeatable. Average HVID of the population as measured by Orbscan is a reliable scale for facial measurements. Medknow Publications & Media Pvt Ltd 2017 /pmc/articles/PMC5782436/ /pubmed/29403183 http://dx.doi.org/10.4103/JCAS.JCAS_61_17 Text en Copyright: © 2018 Journal of Cutaneous and Aesthetic Surgery http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open access article distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 3.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as the author is credited and the new creations are licensed under the identical terms.
spellingShingle Original Article
Rajyalakshmi, R.
Prakash, Winston D.
Ali, Mohammad Javed
Naik, Milind N.
Periorbital Biometric Measurements using ImageJ Software: Standardisation of Technique and Assessment Of Intra- and Interobserver Variability
title Periorbital Biometric Measurements using ImageJ Software: Standardisation of Technique and Assessment Of Intra- and Interobserver Variability
title_full Periorbital Biometric Measurements using ImageJ Software: Standardisation of Technique and Assessment Of Intra- and Interobserver Variability
title_fullStr Periorbital Biometric Measurements using ImageJ Software: Standardisation of Technique and Assessment Of Intra- and Interobserver Variability
title_full_unstemmed Periorbital Biometric Measurements using ImageJ Software: Standardisation of Technique and Assessment Of Intra- and Interobserver Variability
title_short Periorbital Biometric Measurements using ImageJ Software: Standardisation of Technique and Assessment Of Intra- and Interobserver Variability
title_sort periorbital biometric measurements using imagej software: standardisation of technique and assessment of intra- and interobserver variability
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5782436/
https://www.ncbi.nlm.nih.gov/pubmed/29403183
http://dx.doi.org/10.4103/JCAS.JCAS_61_17
work_keys_str_mv AT rajyalakshmir periorbitalbiometricmeasurementsusingimagejsoftwarestandardisationoftechniqueandassessmentofintraandinterobservervariability
AT prakashwinstond periorbitalbiometricmeasurementsusingimagejsoftwarestandardisationoftechniqueandassessmentofintraandinterobservervariability
AT alimohammadjaved periorbitalbiometricmeasurementsusingimagejsoftwarestandardisationoftechniqueandassessmentofintraandinterobservervariability
AT naikmilindn periorbitalbiometricmeasurementsusingimagejsoftwarestandardisationoftechniqueandassessmentofintraandinterobservervariability