Cargando…
Periorbital Biometric Measurements using ImageJ Software: Standardisation of Technique and Assessment Of Intra- and Interobserver Variability
PURPOSE: To assess the reliability and repeatability of periorbital biometric measurements using ImageJ software and to assess if the horizontal visible iris diameter (HVID) serves as a reliable scale for facial measurements. METHODS: This study was a prospective, single-blind, comparative study. Tw...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Medknow Publications & Media Pvt Ltd
2017
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5782436/ https://www.ncbi.nlm.nih.gov/pubmed/29403183 http://dx.doi.org/10.4103/JCAS.JCAS_61_17 |
_version_ | 1783295193023250432 |
---|---|
author | Rajyalakshmi, R. Prakash, Winston D. Ali, Mohammad Javed Naik, Milind N. |
author_facet | Rajyalakshmi, R. Prakash, Winston D. Ali, Mohammad Javed Naik, Milind N. |
author_sort | Rajyalakshmi, R. |
collection | PubMed |
description | PURPOSE: To assess the reliability and repeatability of periorbital biometric measurements using ImageJ software and to assess if the horizontal visible iris diameter (HVID) serves as a reliable scale for facial measurements. METHODS: This study was a prospective, single-blind, comparative study. Two clinicians performed 12 periorbital measurements on 100 standardised face photographs. Each individual’s HVID was determined by Orbscan IIz and used as a scale for measurements using ImageJ software. All measurements were repeated using the ‘average’ HVID of the study population as a measurement scale. Intraclass correlation coefficient (ICC) and Pearson product-moment coefficient were used as statistical tests to analyse the data. RESULTS: The range of ICC for intra- and interobserver variability was 0.79–0.99 and 0.86–0.99, respectively. Test-retest reliability ranged from 0.66–1.0 to 0.77–0.98, respectively. When average HVID of the study population was used as scale, ICC ranged from 0.83 to 0.99, and the test-retest reliability ranged from 0.83 to 0.96 and the measurements correlated well with recordings done with individual Orbscan HVID measurements. CONCLUSION: Periorbital biometric measurements using ImageJ software are reproducible and repeatable. Average HVID of the population as measured by Orbscan is a reliable scale for facial measurements. |
format | Online Article Text |
id | pubmed-5782436 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2017 |
publisher | Medknow Publications & Media Pvt Ltd |
record_format | MEDLINE/PubMed |
spelling | pubmed-57824362018-02-05 Periorbital Biometric Measurements using ImageJ Software: Standardisation of Technique and Assessment Of Intra- and Interobserver Variability Rajyalakshmi, R. Prakash, Winston D. Ali, Mohammad Javed Naik, Milind N. J Cutan Aesthet Surg Original Article PURPOSE: To assess the reliability and repeatability of periorbital biometric measurements using ImageJ software and to assess if the horizontal visible iris diameter (HVID) serves as a reliable scale for facial measurements. METHODS: This study was a prospective, single-blind, comparative study. Two clinicians performed 12 periorbital measurements on 100 standardised face photographs. Each individual’s HVID was determined by Orbscan IIz and used as a scale for measurements using ImageJ software. All measurements were repeated using the ‘average’ HVID of the study population as a measurement scale. Intraclass correlation coefficient (ICC) and Pearson product-moment coefficient were used as statistical tests to analyse the data. RESULTS: The range of ICC for intra- and interobserver variability was 0.79–0.99 and 0.86–0.99, respectively. Test-retest reliability ranged from 0.66–1.0 to 0.77–0.98, respectively. When average HVID of the study population was used as scale, ICC ranged from 0.83 to 0.99, and the test-retest reliability ranged from 0.83 to 0.96 and the measurements correlated well with recordings done with individual Orbscan HVID measurements. CONCLUSION: Periorbital biometric measurements using ImageJ software are reproducible and repeatable. Average HVID of the population as measured by Orbscan is a reliable scale for facial measurements. Medknow Publications & Media Pvt Ltd 2017 /pmc/articles/PMC5782436/ /pubmed/29403183 http://dx.doi.org/10.4103/JCAS.JCAS_61_17 Text en Copyright: © 2018 Journal of Cutaneous and Aesthetic Surgery http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open access article distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 3.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as the author is credited and the new creations are licensed under the identical terms. |
spellingShingle | Original Article Rajyalakshmi, R. Prakash, Winston D. Ali, Mohammad Javed Naik, Milind N. Periorbital Biometric Measurements using ImageJ Software: Standardisation of Technique and Assessment Of Intra- and Interobserver Variability |
title | Periorbital Biometric Measurements using ImageJ Software: Standardisation of Technique and Assessment Of Intra- and Interobserver Variability |
title_full | Periorbital Biometric Measurements using ImageJ Software: Standardisation of Technique and Assessment Of Intra- and Interobserver Variability |
title_fullStr | Periorbital Biometric Measurements using ImageJ Software: Standardisation of Technique and Assessment Of Intra- and Interobserver Variability |
title_full_unstemmed | Periorbital Biometric Measurements using ImageJ Software: Standardisation of Technique and Assessment Of Intra- and Interobserver Variability |
title_short | Periorbital Biometric Measurements using ImageJ Software: Standardisation of Technique and Assessment Of Intra- and Interobserver Variability |
title_sort | periorbital biometric measurements using imagej software: standardisation of technique and assessment of intra- and interobserver variability |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5782436/ https://www.ncbi.nlm.nih.gov/pubmed/29403183 http://dx.doi.org/10.4103/JCAS.JCAS_61_17 |
work_keys_str_mv | AT rajyalakshmir periorbitalbiometricmeasurementsusingimagejsoftwarestandardisationoftechniqueandassessmentofintraandinterobservervariability AT prakashwinstond periorbitalbiometricmeasurementsusingimagejsoftwarestandardisationoftechniqueandassessmentofintraandinterobservervariability AT alimohammadjaved periorbitalbiometricmeasurementsusingimagejsoftwarestandardisationoftechniqueandassessmentofintraandinterobservervariability AT naikmilindn periorbitalbiometricmeasurementsusingimagejsoftwarestandardisationoftechniqueandassessmentofintraandinterobservervariability |