Cargando…

Hybrid blade and locking plate fixation for proximal humerus fractures: a comparative biomechanical analysis

BACKGROUND: Open reduction and internal fixation of proximal humerus fractures can be difficult to achieve adequate, complication free results due to osteopenia of the proximal humerus and unstable fracture patterns. This study aimed to compare the biomechanical properties of a novel hybrid fixed an...

Descripción completa

Detalles Bibliográficos
Autores principales: Jabran, Ali, Peach, Chris, Zou, Zhenmin, Ren, Lei
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5785900/
https://www.ncbi.nlm.nih.gov/pubmed/29370867
http://dx.doi.org/10.1186/s12938-018-0447-y
_version_ 1783295698066735104
author Jabran, Ali
Peach, Chris
Zou, Zhenmin
Ren, Lei
author_facet Jabran, Ali
Peach, Chris
Zou, Zhenmin
Ren, Lei
author_sort Jabran, Ali
collection PubMed
description BACKGROUND: Open reduction and internal fixation of proximal humerus fractures can be difficult to achieve adequate, complication free results due to osteopenia of the proximal humerus and unstable fracture patterns. This study aimed to compare the biomechanical properties of a novel hybrid fixed angle blade plate (Fx plate) with an established fixed angle locking plate (PHILOS plate). METHODS: A two-part fracture was simulated in synthetic composite humeri by creating a transverse osteotomy and 10 mm fracture gap at the surgical neck. After treating the fractures with either an Fx plate or a PHILOS plate, humeral head was fixed and the shaft was displaced in a cantilever fashion. For elastic tests, loading was along the frontal and sagittal plane to achieve varus/valgus and extension/flexion, respectively. In plastic tests, loading was in a varus direction to determine the constructs’ resistance to varus collapse. RESULTS: In elastic tests, both construct types had higher peak load and stiffness in extension/flexion than varus/valgus. Fx plate constructs were significantly stiffer than PHILOS constructs in varus/valgus (mean: 7.590/6.900 vs. 6.609/6.091 N/mm; p < 0.001 for both) but significantly less stiff in extension/flexion (8.770/9.541 vs. 9.533/9.997 N/mm; p < 0.001 for extension, p < 0.05 for flexion). In varus plastic tests, significantly higher peak loads were reported for Fx plate than PHILOS (134.391 vs. 115.531 N; p < 0.001). CONCLUSIONS: In this fracture gap model, humeri implanted with a novel Fx plate provided higher varus/valgus stiffness but lower extension/flexion stiffness than a more traditional proximal humeral locking plate design (PHILOS).
format Online
Article
Text
id pubmed-5785900
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-57859002018-02-07 Hybrid blade and locking plate fixation for proximal humerus fractures: a comparative biomechanical analysis Jabran, Ali Peach, Chris Zou, Zhenmin Ren, Lei Biomed Eng Online Research BACKGROUND: Open reduction and internal fixation of proximal humerus fractures can be difficult to achieve adequate, complication free results due to osteopenia of the proximal humerus and unstable fracture patterns. This study aimed to compare the biomechanical properties of a novel hybrid fixed angle blade plate (Fx plate) with an established fixed angle locking plate (PHILOS plate). METHODS: A two-part fracture was simulated in synthetic composite humeri by creating a transverse osteotomy and 10 mm fracture gap at the surgical neck. After treating the fractures with either an Fx plate or a PHILOS plate, humeral head was fixed and the shaft was displaced in a cantilever fashion. For elastic tests, loading was along the frontal and sagittal plane to achieve varus/valgus and extension/flexion, respectively. In plastic tests, loading was in a varus direction to determine the constructs’ resistance to varus collapse. RESULTS: In elastic tests, both construct types had higher peak load and stiffness in extension/flexion than varus/valgus. Fx plate constructs were significantly stiffer than PHILOS constructs in varus/valgus (mean: 7.590/6.900 vs. 6.609/6.091 N/mm; p < 0.001 for both) but significantly less stiff in extension/flexion (8.770/9.541 vs. 9.533/9.997 N/mm; p < 0.001 for extension, p < 0.05 for flexion). In varus plastic tests, significantly higher peak loads were reported for Fx plate than PHILOS (134.391 vs. 115.531 N; p < 0.001). CONCLUSIONS: In this fracture gap model, humeri implanted with a novel Fx plate provided higher varus/valgus stiffness but lower extension/flexion stiffness than a more traditional proximal humeral locking plate design (PHILOS). BioMed Central 2018-01-25 /pmc/articles/PMC5785900/ /pubmed/29370867 http://dx.doi.org/10.1186/s12938-018-0447-y Text en © The Author(s) 2018 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Research
Jabran, Ali
Peach, Chris
Zou, Zhenmin
Ren, Lei
Hybrid blade and locking plate fixation for proximal humerus fractures: a comparative biomechanical analysis
title Hybrid blade and locking plate fixation for proximal humerus fractures: a comparative biomechanical analysis
title_full Hybrid blade and locking plate fixation for proximal humerus fractures: a comparative biomechanical analysis
title_fullStr Hybrid blade and locking plate fixation for proximal humerus fractures: a comparative biomechanical analysis
title_full_unstemmed Hybrid blade and locking plate fixation for proximal humerus fractures: a comparative biomechanical analysis
title_short Hybrid blade and locking plate fixation for proximal humerus fractures: a comparative biomechanical analysis
title_sort hybrid blade and locking plate fixation for proximal humerus fractures: a comparative biomechanical analysis
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5785900/
https://www.ncbi.nlm.nih.gov/pubmed/29370867
http://dx.doi.org/10.1186/s12938-018-0447-y
work_keys_str_mv AT jabranali hybridbladeandlockingplatefixationforproximalhumerusfracturesacomparativebiomechanicalanalysis
AT peachchris hybridbladeandlockingplatefixationforproximalhumerusfracturesacomparativebiomechanicalanalysis
AT zouzhenmin hybridbladeandlockingplatefixationforproximalhumerusfracturesacomparativebiomechanicalanalysis
AT renlei hybridbladeandlockingplatefixationforproximalhumerusfracturesacomparativebiomechanicalanalysis