Accuracy and reliability of noninvasive stroke volume monitoring via ECG-gated 3D electrical impedance tomography in healthy volunteers

Cardiac output (CO) and stroke volume (SV) are parameters of key clinical interest. Many techniques exist to measure CO and SV, but are either invasive or insufficiently accurate in clinical settings. Electrical impedance tomography (EIT) has been suggested as a noninvasive measure of SV, but incons...

Descripción completa

Detalles Bibliográficos
Autores principales: Braun, Fabian, Proença, Martin, Adler, Andy, Riedel, Thomas, Thiran, Jean-Philippe, Solà, Josep
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5786320/
https://www.ncbi.nlm.nih.gov/pubmed/29373611
http://dx.doi.org/10.1371/journal.pone.0191870
_version_ 1783295768808914944
author Braun, Fabian
Proença, Martin
Adler, Andy
Riedel, Thomas
Thiran, Jean-Philippe
Solà, Josep
author_facet Braun, Fabian
Proença, Martin
Adler, Andy
Riedel, Thomas
Thiran, Jean-Philippe
Solà, Josep
author_sort Braun, Fabian
collection PubMed
description Cardiac output (CO) and stroke volume (SV) are parameters of key clinical interest. Many techniques exist to measure CO and SV, but are either invasive or insufficiently accurate in clinical settings. Electrical impedance tomography (EIT) has been suggested as a noninvasive measure of SV, but inconsistent results have been reported. Our goal is to determine the accuracy and reliability of EIT-based SV measurements, and whether advanced image reconstruction approaches can help to improve the estimates. Data were collected on ten healthy volunteers undergoing postural changes and exercise. To overcome the sensitivity to heart displacement and thorax morphology reported in previous work, we used a 3D EIT configuration with 2 planes of 16 electrodes and subject-specific reconstruction models. Various EIT-derived SV estimates were compared to reference measurements derived from the oxygen uptake. Results revealed a dramatic impact of posture on the EIT images. Therefore, the analysis was restricted to measurements in supine position under controlled conditions (low noise and stable heart and lung regions). In these measurements, amplitudes of impedance changes in the heart and lung regions could successfully be derived from EIT using ECG gating. However, despite a subject-specific calibration the heart-related estimates showed an error of 0.0 ± 15.2 mL for absolute SV estimation. For trending of relative SV changes, a concordance rate of 80.9% and an angular error of −1.0 ± 23.0° were obtained. These performances are insufficient for most clinical uses. Similar conclusions were derived from lung-related estimates. Our findings indicate that the key difficulty in EIT-based SV monitoring is that purely amplitude-based features are strongly influenced by other factors (such as posture, electrode contact impedance and lung or heart conductivity). All the data of the present study are made publicly available for further investigations.
format Online
Article
Text
id pubmed-5786320
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-57863202018-02-09 Accuracy and reliability of noninvasive stroke volume monitoring via ECG-gated 3D electrical impedance tomography in healthy volunteers Braun, Fabian Proença, Martin Adler, Andy Riedel, Thomas Thiran, Jean-Philippe Solà, Josep PLoS One Research Article Cardiac output (CO) and stroke volume (SV) are parameters of key clinical interest. Many techniques exist to measure CO and SV, but are either invasive or insufficiently accurate in clinical settings. Electrical impedance tomography (EIT) has been suggested as a noninvasive measure of SV, but inconsistent results have been reported. Our goal is to determine the accuracy and reliability of EIT-based SV measurements, and whether advanced image reconstruction approaches can help to improve the estimates. Data were collected on ten healthy volunteers undergoing postural changes and exercise. To overcome the sensitivity to heart displacement and thorax morphology reported in previous work, we used a 3D EIT configuration with 2 planes of 16 electrodes and subject-specific reconstruction models. Various EIT-derived SV estimates were compared to reference measurements derived from the oxygen uptake. Results revealed a dramatic impact of posture on the EIT images. Therefore, the analysis was restricted to measurements in supine position under controlled conditions (low noise and stable heart and lung regions). In these measurements, amplitudes of impedance changes in the heart and lung regions could successfully be derived from EIT using ECG gating. However, despite a subject-specific calibration the heart-related estimates showed an error of 0.0 ± 15.2 mL for absolute SV estimation. For trending of relative SV changes, a concordance rate of 80.9% and an angular error of −1.0 ± 23.0° were obtained. These performances are insufficient for most clinical uses. Similar conclusions were derived from lung-related estimates. Our findings indicate that the key difficulty in EIT-based SV monitoring is that purely amplitude-based features are strongly influenced by other factors (such as posture, electrode contact impedance and lung or heart conductivity). All the data of the present study are made publicly available for further investigations. Public Library of Science 2018-01-26 /pmc/articles/PMC5786320/ /pubmed/29373611 http://dx.doi.org/10.1371/journal.pone.0191870 Text en © 2018 Braun et al http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Research Article
Braun, Fabian
Proença, Martin
Adler, Andy
Riedel, Thomas
Thiran, Jean-Philippe
Solà, Josep
Accuracy and reliability of noninvasive stroke volume monitoring via ECG-gated 3D electrical impedance tomography in healthy volunteers
title Accuracy and reliability of noninvasive stroke volume monitoring via ECG-gated 3D electrical impedance tomography in healthy volunteers
title_full Accuracy and reliability of noninvasive stroke volume monitoring via ECG-gated 3D electrical impedance tomography in healthy volunteers
title_fullStr Accuracy and reliability of noninvasive stroke volume monitoring via ECG-gated 3D electrical impedance tomography in healthy volunteers
title_full_unstemmed Accuracy and reliability of noninvasive stroke volume monitoring via ECG-gated 3D electrical impedance tomography in healthy volunteers
title_short Accuracy and reliability of noninvasive stroke volume monitoring via ECG-gated 3D electrical impedance tomography in healthy volunteers
title_sort accuracy and reliability of noninvasive stroke volume monitoring via ecg-gated 3d electrical impedance tomography in healthy volunteers
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5786320/
https://www.ncbi.nlm.nih.gov/pubmed/29373611
http://dx.doi.org/10.1371/journal.pone.0191870
work_keys_str_mv AT braunfabian accuracyandreliabilityofnoninvasivestrokevolumemonitoringviaecggated3delectricalimpedancetomographyinhealthyvolunteers
AT proencamartin accuracyandreliabilityofnoninvasivestrokevolumemonitoringviaecggated3delectricalimpedancetomographyinhealthyvolunteers
AT adlerandy accuracyandreliabilityofnoninvasivestrokevolumemonitoringviaecggated3delectricalimpedancetomographyinhealthyvolunteers
AT riedelthomas accuracyandreliabilityofnoninvasivestrokevolumemonitoringviaecggated3delectricalimpedancetomographyinhealthyvolunteers
AT thiranjeanphilippe accuracyandreliabilityofnoninvasivestrokevolumemonitoringviaecggated3delectricalimpedancetomographyinhealthyvolunteers
AT solajosep accuracyandreliabilityofnoninvasivestrokevolumemonitoringviaecggated3delectricalimpedancetomographyinhealthyvolunteers