An Innovative Technique to Assess Spontaneous Baroreflex Sensitivity with Short Data Segments: Multiple Trigonometric Regressive Spectral Analysis
Objective: As the multiple trigonometric regressive spectral (MTRS) analysis is extraordinary in its ability to analyze short local data segments down to 12 s, we wanted to evaluate the impact of the data segment settings by applying the technique of MTRS analysis for baroreflex sensitivity (BRS) es...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Frontiers Media S.A.
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5786552/ https://www.ncbi.nlm.nih.gov/pubmed/29403393 http://dx.doi.org/10.3389/fphys.2018.00010 |
_version_ | 1783295799879270400 |
---|---|
author | Li, Kai Rüdiger, Heinz Haase, Rocco Ziemssen, Tjalf |
author_facet | Li, Kai Rüdiger, Heinz Haase, Rocco Ziemssen, Tjalf |
author_sort | Li, Kai |
collection | PubMed |
description | Objective: As the multiple trigonometric regressive spectral (MTRS) analysis is extraordinary in its ability to analyze short local data segments down to 12 s, we wanted to evaluate the impact of the data segment settings by applying the technique of MTRS analysis for baroreflex sensitivity (BRS) estimation using a standardized data pool. Methods: Spectral and baroreflex analyses were performed on the EuroBaVar dataset (42 recordings, including lying and standing positions). For this analysis, the technique of MTRS was used. We used different global and local data segment lengths, and chose the global data segments from different positions. Three global data segments of 1 and 2 min and three local data segments of 12, 20, and 30 s were used in MTRS analysis for BRS. Results: All the BRS-values calculated on the three global data segments were highly correlated, both in the supine and standing positions; the different global data segments provided similar BRS estimations. When using different local data segments, all the BRS-values were also highly correlated. However, in the supine position, using short local data segments of 12 s overestimated BRS compared with those using 20 and 30 s. In the standing position, the BRS estimations using different local data segments were comparable. There was no proportional bias for the comparisons between different BRS estimations. Conclusion: We demonstrate that BRS estimation by the MTRS technique is stable when using different global data segments, and MTRS is extraordinary in its ability to evaluate BRS in even short local data segments (20 and 30 s). Because of the non-stationary character of most biosignals, the MTRS technique would be preferable for BRS analysis especially in conditions when only short stationary data segments are available or when dynamic changes of BRS should be monitored. |
format | Online Article Text |
id | pubmed-5786552 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | Frontiers Media S.A. |
record_format | MEDLINE/PubMed |
spelling | pubmed-57865522018-02-05 An Innovative Technique to Assess Spontaneous Baroreflex Sensitivity with Short Data Segments: Multiple Trigonometric Regressive Spectral Analysis Li, Kai Rüdiger, Heinz Haase, Rocco Ziemssen, Tjalf Front Physiol Physiology Objective: As the multiple trigonometric regressive spectral (MTRS) analysis is extraordinary in its ability to analyze short local data segments down to 12 s, we wanted to evaluate the impact of the data segment settings by applying the technique of MTRS analysis for baroreflex sensitivity (BRS) estimation using a standardized data pool. Methods: Spectral and baroreflex analyses were performed on the EuroBaVar dataset (42 recordings, including lying and standing positions). For this analysis, the technique of MTRS was used. We used different global and local data segment lengths, and chose the global data segments from different positions. Three global data segments of 1 and 2 min and three local data segments of 12, 20, and 30 s were used in MTRS analysis for BRS. Results: All the BRS-values calculated on the three global data segments were highly correlated, both in the supine and standing positions; the different global data segments provided similar BRS estimations. When using different local data segments, all the BRS-values were also highly correlated. However, in the supine position, using short local data segments of 12 s overestimated BRS compared with those using 20 and 30 s. In the standing position, the BRS estimations using different local data segments were comparable. There was no proportional bias for the comparisons between different BRS estimations. Conclusion: We demonstrate that BRS estimation by the MTRS technique is stable when using different global data segments, and MTRS is extraordinary in its ability to evaluate BRS in even short local data segments (20 and 30 s). Because of the non-stationary character of most biosignals, the MTRS technique would be preferable for BRS analysis especially in conditions when only short stationary data segments are available or when dynamic changes of BRS should be monitored. Frontiers Media S.A. 2018-01-22 /pmc/articles/PMC5786552/ /pubmed/29403393 http://dx.doi.org/10.3389/fphys.2018.00010 Text en Copyright © 2018 Li, Rüdiger, Haase and Ziemssen. http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) or licensor are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms. |
spellingShingle | Physiology Li, Kai Rüdiger, Heinz Haase, Rocco Ziemssen, Tjalf An Innovative Technique to Assess Spontaneous Baroreflex Sensitivity with Short Data Segments: Multiple Trigonometric Regressive Spectral Analysis |
title | An Innovative Technique to Assess Spontaneous Baroreflex Sensitivity with Short Data Segments: Multiple Trigonometric Regressive Spectral Analysis |
title_full | An Innovative Technique to Assess Spontaneous Baroreflex Sensitivity with Short Data Segments: Multiple Trigonometric Regressive Spectral Analysis |
title_fullStr | An Innovative Technique to Assess Spontaneous Baroreflex Sensitivity with Short Data Segments: Multiple Trigonometric Regressive Spectral Analysis |
title_full_unstemmed | An Innovative Technique to Assess Spontaneous Baroreflex Sensitivity with Short Data Segments: Multiple Trigonometric Regressive Spectral Analysis |
title_short | An Innovative Technique to Assess Spontaneous Baroreflex Sensitivity with Short Data Segments: Multiple Trigonometric Regressive Spectral Analysis |
title_sort | innovative technique to assess spontaneous baroreflex sensitivity with short data segments: multiple trigonometric regressive spectral analysis |
topic | Physiology |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5786552/ https://www.ncbi.nlm.nih.gov/pubmed/29403393 http://dx.doi.org/10.3389/fphys.2018.00010 |
work_keys_str_mv | AT likai aninnovativetechniquetoassessspontaneousbaroreflexsensitivitywithshortdatasegmentsmultipletrigonometricregressivespectralanalysis AT rudigerheinz aninnovativetechniquetoassessspontaneousbaroreflexsensitivitywithshortdatasegmentsmultipletrigonometricregressivespectralanalysis AT haaserocco aninnovativetechniquetoassessspontaneousbaroreflexsensitivitywithshortdatasegmentsmultipletrigonometricregressivespectralanalysis AT ziemssentjalf aninnovativetechniquetoassessspontaneousbaroreflexsensitivitywithshortdatasegmentsmultipletrigonometricregressivespectralanalysis AT likai innovativetechniquetoassessspontaneousbaroreflexsensitivitywithshortdatasegmentsmultipletrigonometricregressivespectralanalysis AT rudigerheinz innovativetechniquetoassessspontaneousbaroreflexsensitivitywithshortdatasegmentsmultipletrigonometricregressivespectralanalysis AT haaserocco innovativetechniquetoassessspontaneousbaroreflexsensitivitywithshortdatasegmentsmultipletrigonometricregressivespectralanalysis AT ziemssentjalf innovativetechniquetoassessspontaneousbaroreflexsensitivitywithshortdatasegmentsmultipletrigonometricregressivespectralanalysis |