Cargando…
Transcatheter and Doppler waveform correlation in transcatheter aortic valve replacement
Transcatheter aortic valve replacement (TAVR) has become the preferred therapy for treatment of severe aortic stenosis in patients at intermediate to high risk of perioperative mortality following surgical aortic valve replacement. Haemodynamic assessment is an integral part of the procedure, and it...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BMJ Publishing Group
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5786907/ https://www.ncbi.nlm.nih.gov/pubmed/29387431 http://dx.doi.org/10.1136/openhrt-2017-000728 |
_version_ | 1783295842032025600 |
---|---|
author | Kalra, Ankur Makkar, Raj R Bhatt, Deepak L Khera, Sahil Kleiman, Neal S Reardon, Michael J Kern, Morton J |
author_facet | Kalra, Ankur Makkar, Raj R Bhatt, Deepak L Khera, Sahil Kleiman, Neal S Reardon, Michael J Kern, Morton J |
author_sort | Kalra, Ankur |
collection | PubMed |
description | Transcatheter aortic valve replacement (TAVR) has become the preferred therapy for treatment of severe aortic stenosis in patients at intermediate to high risk of perioperative mortality following surgical aortic valve replacement. Haemodynamic assessment is an integral part of the procedure, and it is crucial for the operator to have an in-depth understanding of the haemodynamic alterations that occur during balloon aortic valvuloplasty and transcatheter valve deployment. Comprehension of the haemodynamic tracings is also pivotal for early recognition of periprocedural complications. With expanding indications for TAVR, it is imperative for members of the structural heart team to have an in-depth, nuanced understanding of transcatheter haemodynamic waveforms and their correlation with echocardiographic Doppler waveforms that are obtained periprocedurally during TAVR. This review provides a collection of transcatheter haemodynamic tracings and their corresponding Doppler echocardiography correlates that are demonstrative of physiological alterations and pathological lesions (complications) that occur during TAVR. |
format | Online Article Text |
id | pubmed-5786907 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | BMJ Publishing Group |
record_format | MEDLINE/PubMed |
spelling | pubmed-57869072018-01-31 Transcatheter and Doppler waveform correlation in transcatheter aortic valve replacement Kalra, Ankur Makkar, Raj R Bhatt, Deepak L Khera, Sahil Kleiman, Neal S Reardon, Michael J Kern, Morton J Open Heart Review Transcatheter aortic valve replacement (TAVR) has become the preferred therapy for treatment of severe aortic stenosis in patients at intermediate to high risk of perioperative mortality following surgical aortic valve replacement. Haemodynamic assessment is an integral part of the procedure, and it is crucial for the operator to have an in-depth understanding of the haemodynamic alterations that occur during balloon aortic valvuloplasty and transcatheter valve deployment. Comprehension of the haemodynamic tracings is also pivotal for early recognition of periprocedural complications. With expanding indications for TAVR, it is imperative for members of the structural heart team to have an in-depth, nuanced understanding of transcatheter haemodynamic waveforms and their correlation with echocardiographic Doppler waveforms that are obtained periprocedurally during TAVR. This review provides a collection of transcatheter haemodynamic tracings and their corresponding Doppler echocardiography correlates that are demonstrative of physiological alterations and pathological lesions (complications) that occur during TAVR. BMJ Publishing Group 2018-01-11 /pmc/articles/PMC5786907/ /pubmed/29387431 http://dx.doi.org/10.1136/openhrt-2017-000728 Text en © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted. This is an Open Access article distributed in accordance with the Creative Commons Attribution Non Commercial (CC BY-NC 4.0) license, which permits others to distribute, remix, adapt, build upon this work non-commercially, and license their derivative works on different terms, provided the original work is properly cited and the use is non-commercial. See: http://creativecommons.org/licenses/by-nc/4.0/ |
spellingShingle | Review Kalra, Ankur Makkar, Raj R Bhatt, Deepak L Khera, Sahil Kleiman, Neal S Reardon, Michael J Kern, Morton J Transcatheter and Doppler waveform correlation in transcatheter aortic valve replacement |
title | Transcatheter and Doppler waveform correlation in transcatheter aortic valve replacement |
title_full | Transcatheter and Doppler waveform correlation in transcatheter aortic valve replacement |
title_fullStr | Transcatheter and Doppler waveform correlation in transcatheter aortic valve replacement |
title_full_unstemmed | Transcatheter and Doppler waveform correlation in transcatheter aortic valve replacement |
title_short | Transcatheter and Doppler waveform correlation in transcatheter aortic valve replacement |
title_sort | transcatheter and doppler waveform correlation in transcatheter aortic valve replacement |
topic | Review |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5786907/ https://www.ncbi.nlm.nih.gov/pubmed/29387431 http://dx.doi.org/10.1136/openhrt-2017-000728 |
work_keys_str_mv | AT kalraankur transcatheteranddopplerwaveformcorrelationintranscatheteraorticvalvereplacement AT makkarrajr transcatheteranddopplerwaveformcorrelationintranscatheteraorticvalvereplacement AT bhattdeepakl transcatheteranddopplerwaveformcorrelationintranscatheteraorticvalvereplacement AT kherasahil transcatheteranddopplerwaveformcorrelationintranscatheteraorticvalvereplacement AT kleimanneals transcatheteranddopplerwaveformcorrelationintranscatheteraorticvalvereplacement AT reardonmichaelj transcatheteranddopplerwaveformcorrelationintranscatheteraorticvalvereplacement AT kernmortonj transcatheteranddopplerwaveformcorrelationintranscatheteraorticvalvereplacement |