Cargando…

Transcatheter and Doppler waveform correlation in transcatheter aortic valve replacement

Transcatheter aortic valve replacement (TAVR) has become the preferred therapy for treatment of severe aortic stenosis in patients at intermediate to high risk of perioperative mortality following surgical aortic valve replacement. Haemodynamic assessment is an integral part of the procedure, and it...

Descripción completa

Detalles Bibliográficos
Autores principales: Kalra, Ankur, Makkar, Raj R, Bhatt, Deepak L, Khera, Sahil, Kleiman, Neal S, Reardon, Michael J, Kern, Morton J
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BMJ Publishing Group 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5786907/
https://www.ncbi.nlm.nih.gov/pubmed/29387431
http://dx.doi.org/10.1136/openhrt-2017-000728
_version_ 1783295842032025600
author Kalra, Ankur
Makkar, Raj R
Bhatt, Deepak L
Khera, Sahil
Kleiman, Neal S
Reardon, Michael J
Kern, Morton J
author_facet Kalra, Ankur
Makkar, Raj R
Bhatt, Deepak L
Khera, Sahil
Kleiman, Neal S
Reardon, Michael J
Kern, Morton J
author_sort Kalra, Ankur
collection PubMed
description Transcatheter aortic valve replacement (TAVR) has become the preferred therapy for treatment of severe aortic stenosis in patients at intermediate to high risk of perioperative mortality following surgical aortic valve replacement. Haemodynamic assessment is an integral part of the procedure, and it is crucial for the operator to have an in-depth understanding of the haemodynamic alterations that occur during balloon aortic valvuloplasty and transcatheter valve deployment. Comprehension of the haemodynamic tracings is also pivotal for early recognition of periprocedural complications. With expanding indications for TAVR, it is imperative for members of the structural heart team to have an in-depth, nuanced understanding of transcatheter haemodynamic waveforms and their correlation with echocardiographic Doppler waveforms that are obtained periprocedurally during TAVR. This review provides a collection of transcatheter haemodynamic tracings and their corresponding Doppler echocardiography correlates that are demonstrative of physiological alterations and pathological lesions (complications) that occur during TAVR.
format Online
Article
Text
id pubmed-5786907
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher BMJ Publishing Group
record_format MEDLINE/PubMed
spelling pubmed-57869072018-01-31 Transcatheter and Doppler waveform correlation in transcatheter aortic valve replacement Kalra, Ankur Makkar, Raj R Bhatt, Deepak L Khera, Sahil Kleiman, Neal S Reardon, Michael J Kern, Morton J Open Heart Review Transcatheter aortic valve replacement (TAVR) has become the preferred therapy for treatment of severe aortic stenosis in patients at intermediate to high risk of perioperative mortality following surgical aortic valve replacement. Haemodynamic assessment is an integral part of the procedure, and it is crucial for the operator to have an in-depth understanding of the haemodynamic alterations that occur during balloon aortic valvuloplasty and transcatheter valve deployment. Comprehension of the haemodynamic tracings is also pivotal for early recognition of periprocedural complications. With expanding indications for TAVR, it is imperative for members of the structural heart team to have an in-depth, nuanced understanding of transcatheter haemodynamic waveforms and their correlation with echocardiographic Doppler waveforms that are obtained periprocedurally during TAVR. This review provides a collection of transcatheter haemodynamic tracings and their corresponding Doppler echocardiography correlates that are demonstrative of physiological alterations and pathological lesions (complications) that occur during TAVR. BMJ Publishing Group 2018-01-11 /pmc/articles/PMC5786907/ /pubmed/29387431 http://dx.doi.org/10.1136/openhrt-2017-000728 Text en © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted. This is an Open Access article distributed in accordance with the Creative Commons Attribution Non Commercial (CC BY-NC 4.0) license, which permits others to distribute, remix, adapt, build upon this work non-commercially, and license their derivative works on different terms, provided the original work is properly cited and the use is non-commercial. See: http://creativecommons.org/licenses/by-nc/4.0/
spellingShingle Review
Kalra, Ankur
Makkar, Raj R
Bhatt, Deepak L
Khera, Sahil
Kleiman, Neal S
Reardon, Michael J
Kern, Morton J
Transcatheter and Doppler waveform correlation in transcatheter aortic valve replacement
title Transcatheter and Doppler waveform correlation in transcatheter aortic valve replacement
title_full Transcatheter and Doppler waveform correlation in transcatheter aortic valve replacement
title_fullStr Transcatheter and Doppler waveform correlation in transcatheter aortic valve replacement
title_full_unstemmed Transcatheter and Doppler waveform correlation in transcatheter aortic valve replacement
title_short Transcatheter and Doppler waveform correlation in transcatheter aortic valve replacement
title_sort transcatheter and doppler waveform correlation in transcatheter aortic valve replacement
topic Review
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5786907/
https://www.ncbi.nlm.nih.gov/pubmed/29387431
http://dx.doi.org/10.1136/openhrt-2017-000728
work_keys_str_mv AT kalraankur transcatheteranddopplerwaveformcorrelationintranscatheteraorticvalvereplacement
AT makkarrajr transcatheteranddopplerwaveformcorrelationintranscatheteraorticvalvereplacement
AT bhattdeepakl transcatheteranddopplerwaveformcorrelationintranscatheteraorticvalvereplacement
AT kherasahil transcatheteranddopplerwaveformcorrelationintranscatheteraorticvalvereplacement
AT kleimanneals transcatheteranddopplerwaveformcorrelationintranscatheteraorticvalvereplacement
AT reardonmichaelj transcatheteranddopplerwaveformcorrelationintranscatheteraorticvalvereplacement
AT kernmortonj transcatheteranddopplerwaveformcorrelationintranscatheteraorticvalvereplacement