The Relationship of Body Mass Index and Blood Pressure with Corneal Biomechanical Parameters in Healthy Subjects

This study aimed to assess the possible relationship of body mass index (BMI) and blood pressure (BP) with corneal biomechanical parameters in healthy subjects. The study included 88 eyes of 88 healthy subjects aged 20–40 years. After a thorough medical history, a digital sphygmomanometer was used t...

Descripción completa

Detalles Bibliográficos
Autores principales: SEDAGHAT, Mohamad-Reza, ASKARIZADEH, Farshad, NEMATY, Mohsen, NAROOIE-NOORI, Foroozan, HERAVIAN, Javad, RAKHSHANDADI, Tahereh, RAJABI, Sattar
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Medical Hypothesis, Discovery & Innovation Ophthalmology 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5787028/
https://www.ncbi.nlm.nih.gov/pubmed/29392148
_version_ 1783295850691166208
author SEDAGHAT, Mohamad-Reza
ASKARIZADEH, Farshad
NEMATY, Mohsen
NAROOIE-NOORI, Foroozan
HERAVIAN, Javad
RAKHSHANDADI, Tahereh
RAJABI, Sattar
author_facet SEDAGHAT, Mohamad-Reza
ASKARIZADEH, Farshad
NEMATY, Mohsen
NAROOIE-NOORI, Foroozan
HERAVIAN, Javad
RAKHSHANDADI, Tahereh
RAJABI, Sattar
author_sort SEDAGHAT, Mohamad-Reza
collection PubMed
description This study aimed to assess the possible relationship of body mass index (BMI) and blood pressure (BP) with corneal biomechanical parameters in healthy subjects. The study included 88 eyes of 88 healthy subjects aged 20–40 years. After a thorough medical history, a digital sphygmomanometer was used to measure the systolic blood pressure (SBP) and diastolic blood pressure (DBP). In addition, several hematological and biochemical parameters were determined to assess general health. Prior the ophthalmic examination, the body height and weight were measured; then, the BMI was calculated. Finally, after comprehensive ophthalmic examination, all cases were evaluated with Pentacam (Oculus) in order to rule out corneal ectasia; then, the corneal biomechanical parameters of all individuals were measured using the Scheimpflug-based Corvis ST (Oculus Optikgeräte GmbH, Wetzlar, Germany). If the measurements of the hematological and biochemical parameters were within normal range, the results of the Corvis ST, BMI, and BP were included in the analysis carried out with SPSS software. The mean (± standard deviation [SD]) BMI, SBP, DBP, intraocular pressure (IOP), central corneal thickness (CCT), deformation amplitude, radius, and peak distance was 27.24 ± 4.80 kg/m2, 116.47 ± 11.21 mmHg, 80.51 ± 5.68 mmHg, 15.10 ± 1.70 mmHg, 533.10 ± 30.97 micrometer, 1.03 ± 0.11 mm, 7.51 ± 0.86 mm, and 5.03 ± 0.30 mm, respectively. Results showed no significant difference in IOP, CCT, peak distance, radius, and deformation amplitude between different BMI subcategories defined by World Health Organization (all P > 0.05). The results of the Corvis ST showed that corneal biomechanical parameters had no significant correlation with BMI, SBP, and DBP in three subgroups of BMI and all participants (all P > 0.05) but the results showed a positive correlation between CCT and IOP (P < 0.001, r = 0.504) in all participants. CCT and IOP had no correlation with BMI, SBP, and DBP (P > 0.05). This study showed that BMI and BP had no correlation with corneal biomechanical parameters in healthy subjects using the Corvis ST.
format Online
Article
Text
id pubmed-5787028
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher Medical Hypothesis, Discovery & Innovation Ophthalmology
record_format MEDLINE/PubMed
spelling pubmed-57870282018-02-01 The Relationship of Body Mass Index and Blood Pressure with Corneal Biomechanical Parameters in Healthy Subjects SEDAGHAT, Mohamad-Reza ASKARIZADEH, Farshad NEMATY, Mohsen NAROOIE-NOORI, Foroozan HERAVIAN, Javad RAKHSHANDADI, Tahereh RAJABI, Sattar Med Hypothesis Discov Innov Ophthalmol Original Article This study aimed to assess the possible relationship of body mass index (BMI) and blood pressure (BP) with corneal biomechanical parameters in healthy subjects. The study included 88 eyes of 88 healthy subjects aged 20–40 years. After a thorough medical history, a digital sphygmomanometer was used to measure the systolic blood pressure (SBP) and diastolic blood pressure (DBP). In addition, several hematological and biochemical parameters were determined to assess general health. Prior the ophthalmic examination, the body height and weight were measured; then, the BMI was calculated. Finally, after comprehensive ophthalmic examination, all cases were evaluated with Pentacam (Oculus) in order to rule out corneal ectasia; then, the corneal biomechanical parameters of all individuals were measured using the Scheimpflug-based Corvis ST (Oculus Optikgeräte GmbH, Wetzlar, Germany). If the measurements of the hematological and biochemical parameters were within normal range, the results of the Corvis ST, BMI, and BP were included in the analysis carried out with SPSS software. The mean (± standard deviation [SD]) BMI, SBP, DBP, intraocular pressure (IOP), central corneal thickness (CCT), deformation amplitude, radius, and peak distance was 27.24 ± 4.80 kg/m2, 116.47 ± 11.21 mmHg, 80.51 ± 5.68 mmHg, 15.10 ± 1.70 mmHg, 533.10 ± 30.97 micrometer, 1.03 ± 0.11 mm, 7.51 ± 0.86 mm, and 5.03 ± 0.30 mm, respectively. Results showed no significant difference in IOP, CCT, peak distance, radius, and deformation amplitude between different BMI subcategories defined by World Health Organization (all P > 0.05). The results of the Corvis ST showed that corneal biomechanical parameters had no significant correlation with BMI, SBP, and DBP in three subgroups of BMI and all participants (all P > 0.05) but the results showed a positive correlation between CCT and IOP (P < 0.001, r = 0.504) in all participants. CCT and IOP had no correlation with BMI, SBP, and DBP (P > 0.05). This study showed that BMI and BP had no correlation with corneal biomechanical parameters in healthy subjects using the Corvis ST. Medical Hypothesis, Discovery & Innovation Ophthalmology 2017 /pmc/articles/PMC5787028/ /pubmed/29392148 Text en ©2017, Med Hypothesis Discov Innov Ophthalmol. This is an Open Access article distributed under the terms of the Creative Commons Attribution License, (http://creativecommons.org/licenses/by/3.0/) which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
SEDAGHAT, Mohamad-Reza
ASKARIZADEH, Farshad
NEMATY, Mohsen
NAROOIE-NOORI, Foroozan
HERAVIAN, Javad
RAKHSHANDADI, Tahereh
RAJABI, Sattar
The Relationship of Body Mass Index and Blood Pressure with Corneal Biomechanical Parameters in Healthy Subjects
title The Relationship of Body Mass Index and Blood Pressure with Corneal Biomechanical Parameters in Healthy Subjects
title_full The Relationship of Body Mass Index and Blood Pressure with Corneal Biomechanical Parameters in Healthy Subjects
title_fullStr The Relationship of Body Mass Index and Blood Pressure with Corneal Biomechanical Parameters in Healthy Subjects
title_full_unstemmed The Relationship of Body Mass Index and Blood Pressure with Corneal Biomechanical Parameters in Healthy Subjects
title_short The Relationship of Body Mass Index and Blood Pressure with Corneal Biomechanical Parameters in Healthy Subjects
title_sort relationship of body mass index and blood pressure with corneal biomechanical parameters in healthy subjects
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5787028/
https://www.ncbi.nlm.nih.gov/pubmed/29392148
work_keys_str_mv AT sedaghatmohamadreza therelationshipofbodymassindexandbloodpressurewithcornealbiomechanicalparametersinhealthysubjects
AT askarizadehfarshad therelationshipofbodymassindexandbloodpressurewithcornealbiomechanicalparametersinhealthysubjects
AT nematymohsen therelationshipofbodymassindexandbloodpressurewithcornealbiomechanicalparametersinhealthysubjects
AT narooienooriforoozan therelationshipofbodymassindexandbloodpressurewithcornealbiomechanicalparametersinhealthysubjects
AT heravianjavad therelationshipofbodymassindexandbloodpressurewithcornealbiomechanicalparametersinhealthysubjects
AT rakhshandaditahereh therelationshipofbodymassindexandbloodpressurewithcornealbiomechanicalparametersinhealthysubjects
AT rajabisattar therelationshipofbodymassindexandbloodpressurewithcornealbiomechanicalparametersinhealthysubjects
AT sedaghatmohamadreza relationshipofbodymassindexandbloodpressurewithcornealbiomechanicalparametersinhealthysubjects
AT askarizadehfarshad relationshipofbodymassindexandbloodpressurewithcornealbiomechanicalparametersinhealthysubjects
AT nematymohsen relationshipofbodymassindexandbloodpressurewithcornealbiomechanicalparametersinhealthysubjects
AT narooienooriforoozan relationshipofbodymassindexandbloodpressurewithcornealbiomechanicalparametersinhealthysubjects
AT heravianjavad relationshipofbodymassindexandbloodpressurewithcornealbiomechanicalparametersinhealthysubjects
AT rakhshandaditahereh relationshipofbodymassindexandbloodpressurewithcornealbiomechanicalparametersinhealthysubjects
AT rajabisattar relationshipofbodymassindexandbloodpressurewithcornealbiomechanicalparametersinhealthysubjects