Clinical Implementation of Robust Optimization for Craniospinal Irradiation

With robust optimization for spot scanning proton therapy now commercially available, the ability exists to account for setup, range, and interfield uncertainties during optimization. Robust optimization is particularly beneficial for craniospinal irradiation (CSI) where the large target volume lend...

Descripción completa

Detalles Bibliográficos
Autores principales: Tasson, Alexandria, Laack, Nadia N., Beltran, Chris
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5789357/
https://www.ncbi.nlm.nih.gov/pubmed/29301336
http://dx.doi.org/10.3390/cancers10010007
_version_ 1783296258911240192
author Tasson, Alexandria
Laack, Nadia N.
Beltran, Chris
author_facet Tasson, Alexandria
Laack, Nadia N.
Beltran, Chris
author_sort Tasson, Alexandria
collection PubMed
description With robust optimization for spot scanning proton therapy now commercially available, the ability exists to account for setup, range, and interfield uncertainties during optimization. Robust optimization is particularly beneficial for craniospinal irradiation (CSI) where the large target volume lends itself to larger setup uncertainties and the need for robust match lines can all be handled with the uncertainty parameters found inside the optimizer. Suggested robust optimization settings, parameters, and image guidance for CSI patients using proton therapy spot scanning are provided. Useful structures are defined and described. Suggestions are given for perturbations to be entered into the optimizer in order to achieve a plan that provides robust target volume coverage and critical structure sparing as well as a robust match line. Interfield offset effects, a concern when using multifield optimization, can also be addressed within the robust optimizer. A robust optimizer can successfully be employed to produce robust match lines, target volume coverage, and critical structure sparing under specified uncertainties. The robust optimizer can also be used to reduce effects arising from interfield uncertainties. Using robust optimization, a plan robust against setup, range, and interfield uncertainties for craniospinal treatments can be created. Utilizing robust optimization allows one to ensure critical structures are spared and target volumes are covered under the desired uncertainty parameters.
format Online
Article
Text
id pubmed-5789357
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-57893572018-02-02 Clinical Implementation of Robust Optimization for Craniospinal Irradiation Tasson, Alexandria Laack, Nadia N. Beltran, Chris Cancers (Basel) Technical Note With robust optimization for spot scanning proton therapy now commercially available, the ability exists to account for setup, range, and interfield uncertainties during optimization. Robust optimization is particularly beneficial for craniospinal irradiation (CSI) where the large target volume lends itself to larger setup uncertainties and the need for robust match lines can all be handled with the uncertainty parameters found inside the optimizer. Suggested robust optimization settings, parameters, and image guidance for CSI patients using proton therapy spot scanning are provided. Useful structures are defined and described. Suggestions are given for perturbations to be entered into the optimizer in order to achieve a plan that provides robust target volume coverage and critical structure sparing as well as a robust match line. Interfield offset effects, a concern when using multifield optimization, can also be addressed within the robust optimizer. A robust optimizer can successfully be employed to produce robust match lines, target volume coverage, and critical structure sparing under specified uncertainties. The robust optimizer can also be used to reduce effects arising from interfield uncertainties. Using robust optimization, a plan robust against setup, range, and interfield uncertainties for craniospinal treatments can be created. Utilizing robust optimization allows one to ensure critical structures are spared and target volumes are covered under the desired uncertainty parameters. MDPI 2018-01-03 /pmc/articles/PMC5789357/ /pubmed/29301336 http://dx.doi.org/10.3390/cancers10010007 Text en © 2018 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Technical Note
Tasson, Alexandria
Laack, Nadia N.
Beltran, Chris
Clinical Implementation of Robust Optimization for Craniospinal Irradiation
title Clinical Implementation of Robust Optimization for Craniospinal Irradiation
title_full Clinical Implementation of Robust Optimization for Craniospinal Irradiation
title_fullStr Clinical Implementation of Robust Optimization for Craniospinal Irradiation
title_full_unstemmed Clinical Implementation of Robust Optimization for Craniospinal Irradiation
title_short Clinical Implementation of Robust Optimization for Craniospinal Irradiation
title_sort clinical implementation of robust optimization for craniospinal irradiation
topic Technical Note
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5789357/
https://www.ncbi.nlm.nih.gov/pubmed/29301336
http://dx.doi.org/10.3390/cancers10010007
work_keys_str_mv AT tassonalexandria clinicalimplementationofrobustoptimizationforcraniospinalirradiation
AT laacknadian clinicalimplementationofrobustoptimizationforcraniospinalirradiation
AT beltranchris clinicalimplementationofrobustoptimizationforcraniospinalirradiation