Cargando…

Computed tomography as primary postoperative follow-up after laparoscopic Roux-en-Y gastric bypass

AIM: To evaluate upper abdominal computed tomography (CT) scan as primary follow-up after laparoscopic Roux-en-Y gastric bypass (LRYGB). METHODS: This prospective study was approved by the Ethical Committee of the State of Zurich, and informed consent was obtained from all patients. Sixty-one patien...

Descripción completa

Detalles Bibliográficos
Autores principales: Delko, Tarik, Mattiello, Diana, Koestler, Thomas, Zingg, Urs, Potthast, Silke
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Baishideng Publishing Group Inc 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5789378/
https://www.ncbi.nlm.nih.gov/pubmed/29403579
http://dx.doi.org/10.4329/wjr.v10.i1.1
_version_ 1783296263974813696
author Delko, Tarik
Mattiello, Diana
Koestler, Thomas
Zingg, Urs
Potthast, Silke
author_facet Delko, Tarik
Mattiello, Diana
Koestler, Thomas
Zingg, Urs
Potthast, Silke
author_sort Delko, Tarik
collection PubMed
description AIM: To evaluate upper abdominal computed tomography (CT) scan as primary follow-up after laparoscopic Roux-en-Y gastric bypass (LRYGB). METHODS: This prospective study was approved by the Ethical Committee of the State of Zurich, and informed consent was obtained from all patients. Sixty-one patients who underwent LRYGB received upper abdominal CT on postoperative day 1, with the following scan parameters: 0.6 mm collimation, 1.2 mm pitch, CareKV with reference 120 mAs and 120 kV, and 0.5 s rotation time. Diluted water-soluble radiographic contrast-medium (50 mL) was administered to achieve gastric pouch distension without movement of the patient. 3D images were evaluated to assess postoperative complications and the radiation dose received was analysed. RESULTS: From the 70 patients initially enrolled in the study, 9 were excluded from analysis upon the intraoperative decision to perform a sleeve gastrectomy and not a LRYGB. In all of the 61 patients who were included in the analysis, CT was feasible and there were no instances of aspiration or vomiting. In 7 patients, two upper abdominal scans were necessary as the pouch was not distended by contrast medium in the first acquisition. Radiologically, no leak and no relevant stenosis were found on the first postoperative day. These early postoperative CT findings were consistent with the findings at clinical follow-up 6 wk postoperatively, with no leaks, stenosis or obstructions being diagnosed. The average total dose length product in CT was 536.6 mGycm resulting in an average effective dose of 7.8 mSv. The most common surgical complication, superficial surgical site infections (n = 4), always occurred at the upper left trocar site, where the circular stapler had been introduced. CONCLUSION: Early LRYGB postoperative multislice spiral CT scan is feasible, with low morbidity, and provides more accurate anatomical information than standard upper gastrointestinal contrast study.
format Online
Article
Text
id pubmed-5789378
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Baishideng Publishing Group Inc
record_format MEDLINE/PubMed
spelling pubmed-57893782018-02-05 Computed tomography as primary postoperative follow-up after laparoscopic Roux-en-Y gastric bypass Delko, Tarik Mattiello, Diana Koestler, Thomas Zingg, Urs Potthast, Silke World J Radiol Prospective Study AIM: To evaluate upper abdominal computed tomography (CT) scan as primary follow-up after laparoscopic Roux-en-Y gastric bypass (LRYGB). METHODS: This prospective study was approved by the Ethical Committee of the State of Zurich, and informed consent was obtained from all patients. Sixty-one patients who underwent LRYGB received upper abdominal CT on postoperative day 1, with the following scan parameters: 0.6 mm collimation, 1.2 mm pitch, CareKV with reference 120 mAs and 120 kV, and 0.5 s rotation time. Diluted water-soluble radiographic contrast-medium (50 mL) was administered to achieve gastric pouch distension without movement of the patient. 3D images were evaluated to assess postoperative complications and the radiation dose received was analysed. RESULTS: From the 70 patients initially enrolled in the study, 9 were excluded from analysis upon the intraoperative decision to perform a sleeve gastrectomy and not a LRYGB. In all of the 61 patients who were included in the analysis, CT was feasible and there were no instances of aspiration or vomiting. In 7 patients, two upper abdominal scans were necessary as the pouch was not distended by contrast medium in the first acquisition. Radiologically, no leak and no relevant stenosis were found on the first postoperative day. These early postoperative CT findings were consistent with the findings at clinical follow-up 6 wk postoperatively, with no leaks, stenosis or obstructions being diagnosed. The average total dose length product in CT was 536.6 mGycm resulting in an average effective dose of 7.8 mSv. The most common surgical complication, superficial surgical site infections (n = 4), always occurred at the upper left trocar site, where the circular stapler had been introduced. CONCLUSION: Early LRYGB postoperative multislice spiral CT scan is feasible, with low morbidity, and provides more accurate anatomical information than standard upper gastrointestinal contrast study. Baishideng Publishing Group Inc 2018-01-28 2018-01-28 /pmc/articles/PMC5789378/ /pubmed/29403579 http://dx.doi.org/10.4329/wjr.v10.i1.1 Text en ©The Author(s) 2018. Published by Baishideng Publishing Group Inc. All rights reserved. http://creativecommons.org/licenses/by-nc/4.0/ This article is an open-access article which was selected by an in-house editor and fully peer-reviewed by external reviewers. It is distributed in accordance with the Creative Commons Attribution Non Commercial (CC BY-NC 4.0) license, which permits others to distribute, remix, adapt, build upon this work non-commercially, and license their derivative works on different terms, provided the original work is properly cited and the use is non-commercial.
spellingShingle Prospective Study
Delko, Tarik
Mattiello, Diana
Koestler, Thomas
Zingg, Urs
Potthast, Silke
Computed tomography as primary postoperative follow-up after laparoscopic Roux-en-Y gastric bypass
title Computed tomography as primary postoperative follow-up after laparoscopic Roux-en-Y gastric bypass
title_full Computed tomography as primary postoperative follow-up after laparoscopic Roux-en-Y gastric bypass
title_fullStr Computed tomography as primary postoperative follow-up after laparoscopic Roux-en-Y gastric bypass
title_full_unstemmed Computed tomography as primary postoperative follow-up after laparoscopic Roux-en-Y gastric bypass
title_short Computed tomography as primary postoperative follow-up after laparoscopic Roux-en-Y gastric bypass
title_sort computed tomography as primary postoperative follow-up after laparoscopic roux-en-y gastric bypass
topic Prospective Study
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5789378/
https://www.ncbi.nlm.nih.gov/pubmed/29403579
http://dx.doi.org/10.4329/wjr.v10.i1.1
work_keys_str_mv AT delkotarik computedtomographyasprimarypostoperativefollowupafterlaparoscopicrouxenygastricbypass
AT mattiellodiana computedtomographyasprimarypostoperativefollowupafterlaparoscopicrouxenygastricbypass
AT koestlerthomas computedtomographyasprimarypostoperativefollowupafterlaparoscopicrouxenygastricbypass
AT zinggurs computedtomographyasprimarypostoperativefollowupafterlaparoscopicrouxenygastricbypass
AT potthastsilke computedtomographyasprimarypostoperativefollowupafterlaparoscopicrouxenygastricbypass