Cargando…
Highly sensitive assay for the determination of therapeutic peptide desmopressin in human plasma by UPLC–MS/MS()
An analytical method based on ultra-performance liquid chromatography with positive ion electrospray ionization (ESI) coupled with tandem mass spectrometry detection (UPLC–MS/MS) was developed and validated for the determination of therapeutic peptide desmopressin in human plasma. A desmopressin sta...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Xi'an Jiaotong University
2017
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5790683/ https://www.ncbi.nlm.nih.gov/pubmed/29404038 http://dx.doi.org/10.1016/j.jpha.2013.11.002 |
_version_ | 1783296485521096704 |
---|---|
author | Gudlawar, Shiva Kumar Pilli, Nageswara Rao Siddiraju, Sridhar Dwivedi, Jaya |
author_facet | Gudlawar, Shiva Kumar Pilli, Nageswara Rao Siddiraju, Sridhar Dwivedi, Jaya |
author_sort | Gudlawar, Shiva Kumar |
collection | PubMed |
description | An analytical method based on ultra-performance liquid chromatography with positive ion electrospray ionization (ESI) coupled with tandem mass spectrometry detection (UPLC–MS/MS) was developed and validated for the determination of therapeutic peptide desmopressin in human plasma. A desmopressin stable labeled isotope (desmopressin d(8)) was used as an internal standard. Analyte and the internal standard were extracted from 200 µL of human plasma via solid-phase extraction technique using Oasis WCX cartridges. The chromatographic separation was achieved on an Aquity UPLC HSS T3 column by using a gradient mixture of methanol and 1 mM ammonium formate buffer as the mobile phase. The calibration curve obtained was linear (r(2)≥0.99) over the concentration range of 1.01–200 pg/mL. Method validation was performed as per FDA guidelines and the results met the acceptance criteria. The results of the intra- and inter-day precision and accuracy studies were well within the acceptable limits. The proposed method was successfully applied to pharmacokinetic studies in humans. |
format | Online Article Text |
id | pubmed-5790683 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2017 |
publisher | Xi'an Jiaotong University |
record_format | MEDLINE/PubMed |
spelling | pubmed-57906832018-02-05 Highly sensitive assay for the determination of therapeutic peptide desmopressin in human plasma by UPLC–MS/MS() Gudlawar, Shiva Kumar Pilli, Nageswara Rao Siddiraju, Sridhar Dwivedi, Jaya J Pharm Anal Original Research Article An analytical method based on ultra-performance liquid chromatography with positive ion electrospray ionization (ESI) coupled with tandem mass spectrometry detection (UPLC–MS/MS) was developed and validated for the determination of therapeutic peptide desmopressin in human plasma. A desmopressin stable labeled isotope (desmopressin d(8)) was used as an internal standard. Analyte and the internal standard were extracted from 200 µL of human plasma via solid-phase extraction technique using Oasis WCX cartridges. The chromatographic separation was achieved on an Aquity UPLC HSS T3 column by using a gradient mixture of methanol and 1 mM ammonium formate buffer as the mobile phase. The calibration curve obtained was linear (r(2)≥0.99) over the concentration range of 1.01–200 pg/mL. Method validation was performed as per FDA guidelines and the results met the acceptance criteria. The results of the intra- and inter-day precision and accuracy studies were well within the acceptable limits. The proposed method was successfully applied to pharmacokinetic studies in humans. Xi'an Jiaotong University 2017-06 2013-12-27 /pmc/articles/PMC5790683/ /pubmed/29404038 http://dx.doi.org/10.1016/j.jpha.2013.11.002 Text en © 2017 Xi'an Jiaotong University. Production and hosting by Elsevier B.V. http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/). |
spellingShingle | Original Research Article Gudlawar, Shiva Kumar Pilli, Nageswara Rao Siddiraju, Sridhar Dwivedi, Jaya Highly sensitive assay for the determination of therapeutic peptide desmopressin in human plasma by UPLC–MS/MS() |
title | Highly sensitive assay for the determination of therapeutic peptide desmopressin in human plasma by UPLC–MS/MS() |
title_full | Highly sensitive assay for the determination of therapeutic peptide desmopressin in human plasma by UPLC–MS/MS() |
title_fullStr | Highly sensitive assay for the determination of therapeutic peptide desmopressin in human plasma by UPLC–MS/MS() |
title_full_unstemmed | Highly sensitive assay for the determination of therapeutic peptide desmopressin in human plasma by UPLC–MS/MS() |
title_short | Highly sensitive assay for the determination of therapeutic peptide desmopressin in human plasma by UPLC–MS/MS() |
title_sort | highly sensitive assay for the determination of therapeutic peptide desmopressin in human plasma by uplc–ms/ms() |
topic | Original Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5790683/ https://www.ncbi.nlm.nih.gov/pubmed/29404038 http://dx.doi.org/10.1016/j.jpha.2013.11.002 |
work_keys_str_mv | AT gudlawarshivakumar highlysensitiveassayforthedeterminationoftherapeuticpeptidedesmopressininhumanplasmabyuplcmsms AT pillinageswararao highlysensitiveassayforthedeterminationoftherapeuticpeptidedesmopressininhumanplasmabyuplcmsms AT siddirajusridhar highlysensitiveassayforthedeterminationoftherapeuticpeptidedesmopressininhumanplasmabyuplcmsms AT dwivedijaya highlysensitiveassayforthedeterminationoftherapeuticpeptidedesmopressininhumanplasmabyuplcmsms |