Cargando…
Development of a novel stability indicating RP-HPLC method for quantification of Connexin43 mimetic peptide and determination of its degradation kinetics in biological fluids
Connexin43 mimetic peptide (Cx43MP) has been intensively investigated for its therapeutic effect in the management of inflammatory eye conditions, spinal cord injury, wound healing and ischemia-induced brain damage. Here, we report on a validated stability–indicating reversed-phase high performance...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Xi'an Jiaotong University
2017
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5790747/ https://www.ncbi.nlm.nih.gov/pubmed/29404061 http://dx.doi.org/10.1016/j.jpha.2017.06.008 |
_version_ | 1783296501469937664 |
---|---|
author | Bisht, Rohit Rupenthal, Ilva D. Sreebhavan, Sreevalsan Jaiswal, Jagdish K. |
author_facet | Bisht, Rohit Rupenthal, Ilva D. Sreebhavan, Sreevalsan Jaiswal, Jagdish K. |
author_sort | Bisht, Rohit |
collection | PubMed |
description | Connexin43 mimetic peptide (Cx43MP) has been intensively investigated for its therapeutic effect in the management of inflammatory eye conditions, spinal cord injury, wound healing and ischemia-induced brain damage. Here, we report on a validated stability–indicating reversed-phase high performance liquid chromatography (RP-HPLC) method for the quantification of Cx43MP under stress conditions. These included exposure to acid/base, light, oxidation and high temperature. In addition, the degradation kinetics of the peptide were evaluated in bovine vitreous and drug-free human plasma at 37 °C. Detection of Cx43MP was carried out at 214 nm with a retention time of 7.5 min. The method showed excellent linearity over the concentration range of 0.9–250 µg/mL (R(2) ≥ 0.998), and the limits of detection (LOD) and quantification (LOQ) were found to be 0.90 and 2.98 μg/mL, respectively. The accuracy of the method determined by the mean percentage recovery at 7.8, 62.5 and 250 µg/mL was 96.79%, 98.25% and 99.06% with a RSD of < 2.2%. Accelerated stability studies revealed that Cx43MP was more sensitive to basic conditions and completely degraded within 24 h at 37 °C (0% recovery) and within 12 h at 80 °C (0.34% recovery). Cx43MP was found to be more stable in bovine vitreous (t(1/2slow)= 171.8 min) compared to human plasma (t(1/2slow) = 39.3 min) at 37 °C according to the two phase degradation kinetic model. These findings are important for further pre-clinical development of Cx43MP. |
format | Online Article Text |
id | pubmed-5790747 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2017 |
publisher | Xi'an Jiaotong University |
record_format | MEDLINE/PubMed |
spelling | pubmed-57907472018-02-05 Development of a novel stability indicating RP-HPLC method for quantification of Connexin43 mimetic peptide and determination of its degradation kinetics in biological fluids Bisht, Rohit Rupenthal, Ilva D. Sreebhavan, Sreevalsan Jaiswal, Jagdish K. J Pharm Anal Original Research Article Connexin43 mimetic peptide (Cx43MP) has been intensively investigated for its therapeutic effect in the management of inflammatory eye conditions, spinal cord injury, wound healing and ischemia-induced brain damage. Here, we report on a validated stability–indicating reversed-phase high performance liquid chromatography (RP-HPLC) method for the quantification of Cx43MP under stress conditions. These included exposure to acid/base, light, oxidation and high temperature. In addition, the degradation kinetics of the peptide were evaluated in bovine vitreous and drug-free human plasma at 37 °C. Detection of Cx43MP was carried out at 214 nm with a retention time of 7.5 min. The method showed excellent linearity over the concentration range of 0.9–250 µg/mL (R(2) ≥ 0.998), and the limits of detection (LOD) and quantification (LOQ) were found to be 0.90 and 2.98 μg/mL, respectively. The accuracy of the method determined by the mean percentage recovery at 7.8, 62.5 and 250 µg/mL was 96.79%, 98.25% and 99.06% with a RSD of < 2.2%. Accelerated stability studies revealed that Cx43MP was more sensitive to basic conditions and completely degraded within 24 h at 37 °C (0% recovery) and within 12 h at 80 °C (0.34% recovery). Cx43MP was found to be more stable in bovine vitreous (t(1/2slow)= 171.8 min) compared to human plasma (t(1/2slow) = 39.3 min) at 37 °C according to the two phase degradation kinetic model. These findings are important for further pre-clinical development of Cx43MP. Xi'an Jiaotong University 2017-12 2017-06-23 /pmc/articles/PMC5790747/ /pubmed/29404061 http://dx.doi.org/10.1016/j.jpha.2017.06.008 Text en © 2017 Xi'an Jiaotong University. Production and hosting by Elsevier B.V. http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/). |
spellingShingle | Original Research Article Bisht, Rohit Rupenthal, Ilva D. Sreebhavan, Sreevalsan Jaiswal, Jagdish K. Development of a novel stability indicating RP-HPLC method for quantification of Connexin43 mimetic peptide and determination of its degradation kinetics in biological fluids |
title | Development of a novel stability indicating RP-HPLC method for quantification of Connexin43 mimetic peptide and determination of its degradation kinetics in biological fluids |
title_full | Development of a novel stability indicating RP-HPLC method for quantification of Connexin43 mimetic peptide and determination of its degradation kinetics in biological fluids |
title_fullStr | Development of a novel stability indicating RP-HPLC method for quantification of Connexin43 mimetic peptide and determination of its degradation kinetics in biological fluids |
title_full_unstemmed | Development of a novel stability indicating RP-HPLC method for quantification of Connexin43 mimetic peptide and determination of its degradation kinetics in biological fluids |
title_short | Development of a novel stability indicating RP-HPLC method for quantification of Connexin43 mimetic peptide and determination of its degradation kinetics in biological fluids |
title_sort | development of a novel stability indicating rp-hplc method for quantification of connexin43 mimetic peptide and determination of its degradation kinetics in biological fluids |
topic | Original Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5790747/ https://www.ncbi.nlm.nih.gov/pubmed/29404061 http://dx.doi.org/10.1016/j.jpha.2017.06.008 |
work_keys_str_mv | AT bishtrohit developmentofanovelstabilityindicatingrphplcmethodforquantificationofconnexin43mimeticpeptideanddeterminationofitsdegradationkineticsinbiologicalfluids AT rupenthalilvad developmentofanovelstabilityindicatingrphplcmethodforquantificationofconnexin43mimeticpeptideanddeterminationofitsdegradationkineticsinbiologicalfluids AT sreebhavansreevalsan developmentofanovelstabilityindicatingrphplcmethodforquantificationofconnexin43mimeticpeptideanddeterminationofitsdegradationkineticsinbiologicalfluids AT jaiswaljagdishk developmentofanovelstabilityindicatingrphplcmethodforquantificationofconnexin43mimeticpeptideanddeterminationofitsdegradationkineticsinbiologicalfluids |