Cargando…
Subcutaneous pyelovesical bypass – Detour bypass – as a solution for ureteric obstruction
INTRODUCTION: Many patients suffer from unilateral or bilateral hydronephroses caused by pelvic tumors, retroperitoneal fibrosis, occlusion due to radiation therapy or iatrogenic damage to the ureter. Currently, percutaneous nephrostomy or double J stents are primarily used. Nephrostomy deteriorates...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Polish Urological Association
2017
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5791398/ https://www.ncbi.nlm.nih.gov/pubmed/29410898 http://dx.doi.org/10.5173/ceju.2017.1397 |
_version_ | 1783296627629359104 |
---|---|
author | Wrona, Andrzej Jerzy Zgajewski, Jarosław Kopeć, Norbert Chodor, Dominik Kopcza, Paweł Klekot, Stefan |
author_facet | Wrona, Andrzej Jerzy Zgajewski, Jarosław Kopeć, Norbert Chodor, Dominik Kopcza, Paweł Klekot, Stefan |
author_sort | Wrona, Andrzej Jerzy |
collection | PubMed |
description | INTRODUCTION: Many patients suffer from unilateral or bilateral hydronephroses caused by pelvic tumors, retroperitoneal fibrosis, occlusion due to radiation therapy or iatrogenic damage to the ureter. Currently, percutaneous nephrostomy or double J stents are primarily used. Nephrostomy deteriorates a patient’s quality of life and leads to frequent infections, blockage of tubes, or bleeding, while uretral stents are associated with septicemia and irritative bladder symptoms. Thus, a useful solution is a Detour stent. MATERIAL AND METHODS: A Detour stent consists of an outer layer made of polytetrafluoroethylene and an inner layer that is a silicone tube 17 F wide, with perforations on both ends and a radio-opaque ring on the proximal end. The ring allows for the insertion of the Detour to the kidney in the correct way. The Detour is placed subcutaneously to the kidney and to the bladder. The route is then tunneled by the large plastic hollow tube for inserting the Detour, and its distal end is sutured to the bladder. RESULTS: Twelve patients were operated using this method, one of which received a Detour stent bilaterally. The mean follow-up was 10 months. All patients were operated previously by different methods. The average time of surgery was 78 minutes. The following complications occurred: urinary tract infections, haematoma, obstructed flow of urine through the Detour stent, prolonged urinary leakage, and pyelonephritis. CONCLUSIONS: Subcutaneous nephrovesical bypass – Detour System – is a minimally invasive, safe and effective procedure that improves quality of life with no serious complications. The Detour System allows urine to be drained in those cases where many other treatments had failed or were not feasible. |
format | Online Article Text |
id | pubmed-5791398 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2017 |
publisher | Polish Urological Association |
record_format | MEDLINE/PubMed |
spelling | pubmed-57913982018-02-06 Subcutaneous pyelovesical bypass – Detour bypass – as a solution for ureteric obstruction Wrona, Andrzej Jerzy Zgajewski, Jarosław Kopeć, Norbert Chodor, Dominik Kopcza, Paweł Klekot, Stefan Cent European J Urol Original Paper INTRODUCTION: Many patients suffer from unilateral or bilateral hydronephroses caused by pelvic tumors, retroperitoneal fibrosis, occlusion due to radiation therapy or iatrogenic damage to the ureter. Currently, percutaneous nephrostomy or double J stents are primarily used. Nephrostomy deteriorates a patient’s quality of life and leads to frequent infections, blockage of tubes, or bleeding, while uretral stents are associated with septicemia and irritative bladder symptoms. Thus, a useful solution is a Detour stent. MATERIAL AND METHODS: A Detour stent consists of an outer layer made of polytetrafluoroethylene and an inner layer that is a silicone tube 17 F wide, with perforations on both ends and a radio-opaque ring on the proximal end. The ring allows for the insertion of the Detour to the kidney in the correct way. The Detour is placed subcutaneously to the kidney and to the bladder. The route is then tunneled by the large plastic hollow tube for inserting the Detour, and its distal end is sutured to the bladder. RESULTS: Twelve patients were operated using this method, one of which received a Detour stent bilaterally. The mean follow-up was 10 months. All patients were operated previously by different methods. The average time of surgery was 78 minutes. The following complications occurred: urinary tract infections, haematoma, obstructed flow of urine through the Detour stent, prolonged urinary leakage, and pyelonephritis. CONCLUSIONS: Subcutaneous nephrovesical bypass – Detour System – is a minimally invasive, safe and effective procedure that improves quality of life with no serious complications. The Detour System allows urine to be drained in those cases where many other treatments had failed or were not feasible. Polish Urological Association 2017-10-17 2017 /pmc/articles/PMC5791398/ /pubmed/29410898 http://dx.doi.org/10.5173/ceju.2017.1397 Text en Copyright by Polish Urological Association http://creativecommons.org/licenses/by-nc-sa/4.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 International (CC BY-NC-SA 4.0) License, allowing third parties to copy and redistribute the material in any medium or format and to remix, transform, and build upon the material, provided the original work is properly cited and states its license. |
spellingShingle | Original Paper Wrona, Andrzej Jerzy Zgajewski, Jarosław Kopeć, Norbert Chodor, Dominik Kopcza, Paweł Klekot, Stefan Subcutaneous pyelovesical bypass – Detour bypass – as a solution for ureteric obstruction |
title | Subcutaneous pyelovesical bypass – Detour bypass – as a solution for ureteric obstruction |
title_full | Subcutaneous pyelovesical bypass – Detour bypass – as a solution for ureteric obstruction |
title_fullStr | Subcutaneous pyelovesical bypass – Detour bypass – as a solution for ureteric obstruction |
title_full_unstemmed | Subcutaneous pyelovesical bypass – Detour bypass – as a solution for ureteric obstruction |
title_short | Subcutaneous pyelovesical bypass – Detour bypass – as a solution for ureteric obstruction |
title_sort | subcutaneous pyelovesical bypass – detour bypass – as a solution for ureteric obstruction |
topic | Original Paper |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5791398/ https://www.ncbi.nlm.nih.gov/pubmed/29410898 http://dx.doi.org/10.5173/ceju.2017.1397 |
work_keys_str_mv | AT wronaandrzejjerzy subcutaneouspyelovesicalbypassdetourbypassasasolutionforuretericobstruction AT zgajewskijarosław subcutaneouspyelovesicalbypassdetourbypassasasolutionforuretericobstruction AT kopecnorbert subcutaneouspyelovesicalbypassdetourbypassasasolutionforuretericobstruction AT chodordominik subcutaneouspyelovesicalbypassdetourbypassasasolutionforuretericobstruction AT kopczapaweł subcutaneouspyelovesicalbypassdetourbypassasasolutionforuretericobstruction AT klekotstefan subcutaneouspyelovesicalbypassdetourbypassasasolutionforuretericobstruction |