Simple motion correction strategy reduces respiratory-induced motion artifacts for k-t accelerated and compressed-sensing cardiovascular magnetic resonance perfusion imaging

BACKGROUND: Cardiovascular magnetic resonance (CMR) stress perfusion imaging provides important diagnostic and prognostic information in coronary artery disease (CAD). Current clinical sequences have limited temporal and/or spatial resolution, and incomplete heart coverage. Techniques such as k-t pr...

Descripción completa

Detalles Bibliográficos
Autores principales: Zhou, Ruixi, Huang, Wei, Yang, Yang, Chen, Xiao, Weller, Daniel S., Kramer, Christopher M., Kozerke, Sebastian, Salerno, Michael
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5793398/
https://www.ncbi.nlm.nih.gov/pubmed/29386056
http://dx.doi.org/10.1186/s12968-018-0427-1
_version_ 1783296943457304576
author Zhou, Ruixi
Huang, Wei
Yang, Yang
Chen, Xiao
Weller, Daniel S.
Kramer, Christopher M.
Kozerke, Sebastian
Salerno, Michael
author_facet Zhou, Ruixi
Huang, Wei
Yang, Yang
Chen, Xiao
Weller, Daniel S.
Kramer, Christopher M.
Kozerke, Sebastian
Salerno, Michael
author_sort Zhou, Ruixi
collection PubMed
description BACKGROUND: Cardiovascular magnetic resonance (CMR) stress perfusion imaging provides important diagnostic and prognostic information in coronary artery disease (CAD). Current clinical sequences have limited temporal and/or spatial resolution, and incomplete heart coverage. Techniques such as k-t principal component analysis (PCA) or k-t sparcity and low rank structure (SLR), which rely on the high degree of spatiotemporal correlation in first-pass perfusion data, can significantly accelerate image acquisition mitigating these problems. However, in the presence of respiratory motion, these techniques can suffer from significant degradation of image quality. A number of techniques based on non-rigid registration have been developed. However, to first approximation, breathing motion predominantly results in rigid motion of the heart. To this end, a simple robust motion correction strategy is proposed for k-t accelerated and compressed sensing (CS) perfusion imaging. METHODS: A simple respiratory motion compensation (MC) strategy for k-t accelerated and compressed-sensing CMR perfusion imaging to selectively correct respiratory motion of the heart was implemented based on linear k-space phase shifts derived from rigid motion registration of a region-of-interest (ROI) encompassing the heart. A variable density Poisson disk acquisition strategy was used to minimize coherent aliasing in the presence of respiratory motion, and images were reconstructed using k-t PCA and k-t SLR with or without motion correction. The strategy was evaluated in a CMR-extended cardiac torso digital (XCAT) phantom and in prospectively acquired first-pass perfusion studies in 12 subjects undergoing clinically ordered CMR studies. Phantom studies were assessed using the Structural Similarity Index (SSIM) and Root Mean Square Error (RMSE). In patient studies, image quality was scored in a blinded fashion by two experienced cardiologists. RESULTS: In the phantom experiments, images reconstructed with the MC strategy had higher SSIM (p < 0.01) and lower RMSE (p < 0.01) in the presence of respiratory motion. For patient studies, the MC strategy improved k-t PCA and k-t SLR reconstruction image quality (p < 0.01). The performance of k-t SLR without motion correction demonstrated improved image quality as compared to k-t PCA in the setting of respiratory motion (p < 0.01), while with motion correction there is a trend of better performance in k-t SLR as compared with motion corrected k-t PCA. CONCLUSIONS: Our simple and robust rigid motion compensation strategy greatly reduces motion artifacts and improves image quality for standard k-t PCA and k-t SLR techniques in setting of respiratory motion due to imperfect breath-holding.
format Online
Article
Text
id pubmed-5793398
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-57933982018-02-12 Simple motion correction strategy reduces respiratory-induced motion artifacts for k-t accelerated and compressed-sensing cardiovascular magnetic resonance perfusion imaging Zhou, Ruixi Huang, Wei Yang, Yang Chen, Xiao Weller, Daniel S. Kramer, Christopher M. Kozerke, Sebastian Salerno, Michael J Cardiovasc Magn Reson Research BACKGROUND: Cardiovascular magnetic resonance (CMR) stress perfusion imaging provides important diagnostic and prognostic information in coronary artery disease (CAD). Current clinical sequences have limited temporal and/or spatial resolution, and incomplete heart coverage. Techniques such as k-t principal component analysis (PCA) or k-t sparcity and low rank structure (SLR), which rely on the high degree of spatiotemporal correlation in first-pass perfusion data, can significantly accelerate image acquisition mitigating these problems. However, in the presence of respiratory motion, these techniques can suffer from significant degradation of image quality. A number of techniques based on non-rigid registration have been developed. However, to first approximation, breathing motion predominantly results in rigid motion of the heart. To this end, a simple robust motion correction strategy is proposed for k-t accelerated and compressed sensing (CS) perfusion imaging. METHODS: A simple respiratory motion compensation (MC) strategy for k-t accelerated and compressed-sensing CMR perfusion imaging to selectively correct respiratory motion of the heart was implemented based on linear k-space phase shifts derived from rigid motion registration of a region-of-interest (ROI) encompassing the heart. A variable density Poisson disk acquisition strategy was used to minimize coherent aliasing in the presence of respiratory motion, and images were reconstructed using k-t PCA and k-t SLR with or without motion correction. The strategy was evaluated in a CMR-extended cardiac torso digital (XCAT) phantom and in prospectively acquired first-pass perfusion studies in 12 subjects undergoing clinically ordered CMR studies. Phantom studies were assessed using the Structural Similarity Index (SSIM) and Root Mean Square Error (RMSE). In patient studies, image quality was scored in a blinded fashion by two experienced cardiologists. RESULTS: In the phantom experiments, images reconstructed with the MC strategy had higher SSIM (p < 0.01) and lower RMSE (p < 0.01) in the presence of respiratory motion. For patient studies, the MC strategy improved k-t PCA and k-t SLR reconstruction image quality (p < 0.01). The performance of k-t SLR without motion correction demonstrated improved image quality as compared to k-t PCA in the setting of respiratory motion (p < 0.01), while with motion correction there is a trend of better performance in k-t SLR as compared with motion corrected k-t PCA. CONCLUSIONS: Our simple and robust rigid motion compensation strategy greatly reduces motion artifacts and improves image quality for standard k-t PCA and k-t SLR techniques in setting of respiratory motion due to imperfect breath-holding. BioMed Central 2018-02-01 /pmc/articles/PMC5793398/ /pubmed/29386056 http://dx.doi.org/10.1186/s12968-018-0427-1 Text en © The Author(s). 2018 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Research
Zhou, Ruixi
Huang, Wei
Yang, Yang
Chen, Xiao
Weller, Daniel S.
Kramer, Christopher M.
Kozerke, Sebastian
Salerno, Michael
Simple motion correction strategy reduces respiratory-induced motion artifacts for k-t accelerated and compressed-sensing cardiovascular magnetic resonance perfusion imaging
title Simple motion correction strategy reduces respiratory-induced motion artifacts for k-t accelerated and compressed-sensing cardiovascular magnetic resonance perfusion imaging
title_full Simple motion correction strategy reduces respiratory-induced motion artifacts for k-t accelerated and compressed-sensing cardiovascular magnetic resonance perfusion imaging
title_fullStr Simple motion correction strategy reduces respiratory-induced motion artifacts for k-t accelerated and compressed-sensing cardiovascular magnetic resonance perfusion imaging
title_full_unstemmed Simple motion correction strategy reduces respiratory-induced motion artifacts for k-t accelerated and compressed-sensing cardiovascular magnetic resonance perfusion imaging
title_short Simple motion correction strategy reduces respiratory-induced motion artifacts for k-t accelerated and compressed-sensing cardiovascular magnetic resonance perfusion imaging
title_sort simple motion correction strategy reduces respiratory-induced motion artifacts for k-t accelerated and compressed-sensing cardiovascular magnetic resonance perfusion imaging
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5793398/
https://www.ncbi.nlm.nih.gov/pubmed/29386056
http://dx.doi.org/10.1186/s12968-018-0427-1
work_keys_str_mv AT zhouruixi simplemotioncorrectionstrategyreducesrespiratoryinducedmotionartifactsforktacceleratedandcompressedsensingcardiovascularmagneticresonanceperfusionimaging
AT huangwei simplemotioncorrectionstrategyreducesrespiratoryinducedmotionartifactsforktacceleratedandcompressedsensingcardiovascularmagneticresonanceperfusionimaging
AT yangyang simplemotioncorrectionstrategyreducesrespiratoryinducedmotionartifactsforktacceleratedandcompressedsensingcardiovascularmagneticresonanceperfusionimaging
AT chenxiao simplemotioncorrectionstrategyreducesrespiratoryinducedmotionartifactsforktacceleratedandcompressedsensingcardiovascularmagneticresonanceperfusionimaging
AT wellerdaniels simplemotioncorrectionstrategyreducesrespiratoryinducedmotionartifactsforktacceleratedandcompressedsensingcardiovascularmagneticresonanceperfusionimaging
AT kramerchristopherm simplemotioncorrectionstrategyreducesrespiratoryinducedmotionartifactsforktacceleratedandcompressedsensingcardiovascularmagneticresonanceperfusionimaging
AT kozerkesebastian simplemotioncorrectionstrategyreducesrespiratoryinducedmotionartifactsforktacceleratedandcompressedsensingcardiovascularmagneticresonanceperfusionimaging
AT salernomichael simplemotioncorrectionstrategyreducesrespiratoryinducedmotionartifactsforktacceleratedandcompressedsensingcardiovascularmagneticresonanceperfusionimaging