Tensile and Creep Testing of Sanicro 25 Using Miniature Specimens
Tensile and creep properties of new austenitic steel Sanicro 25 at room temperature and operating temperature 700 °C were investigated by testing on miniature specimens. The results were correlated with testing on conventional specimens. Very good agreement of results was obtained, namely in yield a...
Autores principales: | Dymáček, Petr, Jarý, Milan, Dobeš, Ferdinand, Kloc, Luboš |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5793640/ https://www.ncbi.nlm.nih.gov/pubmed/29337867 http://dx.doi.org/10.3390/ma11010142 |
Ejemplares similares
-
Use of the Wilshire Equations to Correlate and Extrapolate Creep Data of HR6W and Sanicro 25
por: Cedro, Vito, et al.
Publicado: (2018) -
Evolution of Precipitated Phases during Creep of G115/Sanicro25 Dissimilar Steel Welded Joints
por: Yang, Maohong, et al.
Publicado: (2021) -
Influence of Hot Consolidation Conditions and Cr-Alloying on Microstructure and Creep in New-Generation ODS Alloy at 1100 °C
por: Svoboda, Jiří, et al.
Publicado: (2020) -
Microstructural Characterisation of Austenitic Heat Resistant Sanicro 25 Steel after Steam Oxidation
por: Rutkowski, Bogdan
Publicado: (2020) -
Optimum Design of a Ceramic Tensile Creep Specimen Using a Finite Element Method
por: Wang, Z., et al.
Publicado: (1997)