Cargando…

Fatigue Reliability Assessment for Orthotropic Steel Decks Based on Long-Term Strain Monitoring

A time-dependent fatigue reliability assessment approach is proposed for welded details of orthotropic steel decks (OSDs) using long-term strain monitoring data. The fatigue reliability limit function of the welded details is established based on the Eurocode specifications. Depending on the distrib...

Descripción completa

Detalles Bibliográficos
Autores principales: Deng, Yang, Li, Aiqun, Feng, Dongming
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5795464/
https://www.ncbi.nlm.nih.gov/pubmed/29320460
http://dx.doi.org/10.3390/s18010181
_version_ 1783297302201368576
author Deng, Yang
Li, Aiqun
Feng, Dongming
author_facet Deng, Yang
Li, Aiqun
Feng, Dongming
author_sort Deng, Yang
collection PubMed
description A time-dependent fatigue reliability assessment approach is proposed for welded details of orthotropic steel decks (OSDs) using long-term strain monitoring data. The fatigue reliability limit function of the welded details is established based on the Eurocode specifications. Depending on the distribution characteristics of the measured daily equivalent stress range, either the lognormal distribution or Gaussian mixture model (GMM) is selected to quantify its uncertainty. Subsequently, the fatigue reliability can be calculated using either an explicit formula or the Monte Carlo method. This proposed approach is applied for the fatigue reliability evaluation of two rib-to-deck and two rib-to-rib welded fatigue details of an in-service suspension bridge. The results show that the reliability indices decrease significantly with bridge’s service life. Except for a rib-to-deck detail, all other three welded details cannot meet the target fatigue reliability during this bridge’s 100-year service life. The proposed approach can help bridge owners and operators make informed decisions regarding maintenance and repair of potential fatigue cracks.
format Online
Article
Text
id pubmed-5795464
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-57954642018-02-13 Fatigue Reliability Assessment for Orthotropic Steel Decks Based on Long-Term Strain Monitoring Deng, Yang Li, Aiqun Feng, Dongming Sensors (Basel) Article A time-dependent fatigue reliability assessment approach is proposed for welded details of orthotropic steel decks (OSDs) using long-term strain monitoring data. The fatigue reliability limit function of the welded details is established based on the Eurocode specifications. Depending on the distribution characteristics of the measured daily equivalent stress range, either the lognormal distribution or Gaussian mixture model (GMM) is selected to quantify its uncertainty. Subsequently, the fatigue reliability can be calculated using either an explicit formula or the Monte Carlo method. This proposed approach is applied for the fatigue reliability evaluation of two rib-to-deck and two rib-to-rib welded fatigue details of an in-service suspension bridge. The results show that the reliability indices decrease significantly with bridge’s service life. Except for a rib-to-deck detail, all other three welded details cannot meet the target fatigue reliability during this bridge’s 100-year service life. The proposed approach can help bridge owners and operators make informed decisions regarding maintenance and repair of potential fatigue cracks. MDPI 2018-01-10 /pmc/articles/PMC5795464/ /pubmed/29320460 http://dx.doi.org/10.3390/s18010181 Text en © 2018 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Deng, Yang
Li, Aiqun
Feng, Dongming
Fatigue Reliability Assessment for Orthotropic Steel Decks Based on Long-Term Strain Monitoring
title Fatigue Reliability Assessment for Orthotropic Steel Decks Based on Long-Term Strain Monitoring
title_full Fatigue Reliability Assessment for Orthotropic Steel Decks Based on Long-Term Strain Monitoring
title_fullStr Fatigue Reliability Assessment for Orthotropic Steel Decks Based on Long-Term Strain Monitoring
title_full_unstemmed Fatigue Reliability Assessment for Orthotropic Steel Decks Based on Long-Term Strain Monitoring
title_short Fatigue Reliability Assessment for Orthotropic Steel Decks Based on Long-Term Strain Monitoring
title_sort fatigue reliability assessment for orthotropic steel decks based on long-term strain monitoring
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5795464/
https://www.ncbi.nlm.nih.gov/pubmed/29320460
http://dx.doi.org/10.3390/s18010181
work_keys_str_mv AT dengyang fatiguereliabilityassessmentfororthotropicsteeldecksbasedonlongtermstrainmonitoring
AT liaiqun fatiguereliabilityassessmentfororthotropicsteeldecksbasedonlongtermstrainmonitoring
AT fengdongming fatiguereliabilityassessmentfororthotropicsteeldecksbasedonlongtermstrainmonitoring