Cargando…

The Effect of the Accelerometer Operating Range on Biomechanical Parameters: Stride Length, Velocity, and Peak Tibial Acceleration during Running

Previous studies have used accelerometers with various operating ranges (ORs) when measuring biomechanical parameters. However, it is still unclear whether ORs influence the accuracy of running parameters, and whether the different stiffnesses of footwear midsoles influence this accuracy. The purpos...

Descripción completa

Detalles Bibliográficos
Autores principales: Mitschke, Christian, Kiesewetter, Pierre, Milani, Thomas L.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5795747/
https://www.ncbi.nlm.nih.gov/pubmed/29303986
http://dx.doi.org/10.3390/s18010130
_version_ 1783297355491049472
author Mitschke, Christian
Kiesewetter, Pierre
Milani, Thomas L.
author_facet Mitschke, Christian
Kiesewetter, Pierre
Milani, Thomas L.
author_sort Mitschke, Christian
collection PubMed
description Previous studies have used accelerometers with various operating ranges (ORs) when measuring biomechanical parameters. However, it is still unclear whether ORs influence the accuracy of running parameters, and whether the different stiffnesses of footwear midsoles influence this accuracy. The purpose of the present study was to systematically investigate the influence of OR on the accuracy of stride length, running velocity, and on peak tibial acceleration. Twenty-one recreational heel strike runners ran on a 15-m indoor track at self-selected running speeds in three footwear conditions (low to high midsole stiffness). Runners were equipped with an inertial measurement unit (IMU) affixed to the heel cup of the right shoe and with a uniaxial accelerometer at the right tibia. Accelerometers (at the tibia and included in the IMU) with a high OR of ±70 g were used as the reference and the data were cut at ±32, ±16, and at ±8 g in post-processing, before calculating parameters. The results show that the OR influenced the outcomes of all investigated parameters, which were not influenced by tested footwear conditions. The lower ORs were associated with an underestimation error for all biomechanical parameters, which increased noticeably with a decreasing OR. It can be concluded that accelerometers with a minimum OR of ±32 g should be used to avoid inaccurate measurements.
format Online
Article
Text
id pubmed-5795747
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-57957472018-02-13 The Effect of the Accelerometer Operating Range on Biomechanical Parameters: Stride Length, Velocity, and Peak Tibial Acceleration during Running Mitschke, Christian Kiesewetter, Pierre Milani, Thomas L. Sensors (Basel) Article Previous studies have used accelerometers with various operating ranges (ORs) when measuring biomechanical parameters. However, it is still unclear whether ORs influence the accuracy of running parameters, and whether the different stiffnesses of footwear midsoles influence this accuracy. The purpose of the present study was to systematically investigate the influence of OR on the accuracy of stride length, running velocity, and on peak tibial acceleration. Twenty-one recreational heel strike runners ran on a 15-m indoor track at self-selected running speeds in three footwear conditions (low to high midsole stiffness). Runners were equipped with an inertial measurement unit (IMU) affixed to the heel cup of the right shoe and with a uniaxial accelerometer at the right tibia. Accelerometers (at the tibia and included in the IMU) with a high OR of ±70 g were used as the reference and the data were cut at ±32, ±16, and at ±8 g in post-processing, before calculating parameters. The results show that the OR influenced the outcomes of all investigated parameters, which were not influenced by tested footwear conditions. The lower ORs were associated with an underestimation error for all biomechanical parameters, which increased noticeably with a decreasing OR. It can be concluded that accelerometers with a minimum OR of ±32 g should be used to avoid inaccurate measurements. MDPI 2018-01-05 /pmc/articles/PMC5795747/ /pubmed/29303986 http://dx.doi.org/10.3390/s18010130 Text en © 2018 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Mitschke, Christian
Kiesewetter, Pierre
Milani, Thomas L.
The Effect of the Accelerometer Operating Range on Biomechanical Parameters: Stride Length, Velocity, and Peak Tibial Acceleration during Running
title The Effect of the Accelerometer Operating Range on Biomechanical Parameters: Stride Length, Velocity, and Peak Tibial Acceleration during Running
title_full The Effect of the Accelerometer Operating Range on Biomechanical Parameters: Stride Length, Velocity, and Peak Tibial Acceleration during Running
title_fullStr The Effect of the Accelerometer Operating Range on Biomechanical Parameters: Stride Length, Velocity, and Peak Tibial Acceleration during Running
title_full_unstemmed The Effect of the Accelerometer Operating Range on Biomechanical Parameters: Stride Length, Velocity, and Peak Tibial Acceleration during Running
title_short The Effect of the Accelerometer Operating Range on Biomechanical Parameters: Stride Length, Velocity, and Peak Tibial Acceleration during Running
title_sort effect of the accelerometer operating range on biomechanical parameters: stride length, velocity, and peak tibial acceleration during running
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5795747/
https://www.ncbi.nlm.nih.gov/pubmed/29303986
http://dx.doi.org/10.3390/s18010130
work_keys_str_mv AT mitschkechristian theeffectoftheaccelerometeroperatingrangeonbiomechanicalparametersstridelengthvelocityandpeaktibialaccelerationduringrunning
AT kiesewetterpierre theeffectoftheaccelerometeroperatingrangeonbiomechanicalparametersstridelengthvelocityandpeaktibialaccelerationduringrunning
AT milanithomasl theeffectoftheaccelerometeroperatingrangeonbiomechanicalparametersstridelengthvelocityandpeaktibialaccelerationduringrunning
AT mitschkechristian effectoftheaccelerometeroperatingrangeonbiomechanicalparametersstridelengthvelocityandpeaktibialaccelerationduringrunning
AT kiesewetterpierre effectoftheaccelerometeroperatingrangeonbiomechanicalparametersstridelengthvelocityandpeaktibialaccelerationduringrunning
AT milanithomasl effectoftheaccelerometeroperatingrangeonbiomechanicalparametersstridelengthvelocityandpeaktibialaccelerationduringrunning