Cargando…
The Effect of the Accelerometer Operating Range on Biomechanical Parameters: Stride Length, Velocity, and Peak Tibial Acceleration during Running
Previous studies have used accelerometers with various operating ranges (ORs) when measuring biomechanical parameters. However, it is still unclear whether ORs influence the accuracy of running parameters, and whether the different stiffnesses of footwear midsoles influence this accuracy. The purpos...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5795747/ https://www.ncbi.nlm.nih.gov/pubmed/29303986 http://dx.doi.org/10.3390/s18010130 |
_version_ | 1783297355491049472 |
---|---|
author | Mitschke, Christian Kiesewetter, Pierre Milani, Thomas L. |
author_facet | Mitschke, Christian Kiesewetter, Pierre Milani, Thomas L. |
author_sort | Mitschke, Christian |
collection | PubMed |
description | Previous studies have used accelerometers with various operating ranges (ORs) when measuring biomechanical parameters. However, it is still unclear whether ORs influence the accuracy of running parameters, and whether the different stiffnesses of footwear midsoles influence this accuracy. The purpose of the present study was to systematically investigate the influence of OR on the accuracy of stride length, running velocity, and on peak tibial acceleration. Twenty-one recreational heel strike runners ran on a 15-m indoor track at self-selected running speeds in three footwear conditions (low to high midsole stiffness). Runners were equipped with an inertial measurement unit (IMU) affixed to the heel cup of the right shoe and with a uniaxial accelerometer at the right tibia. Accelerometers (at the tibia and included in the IMU) with a high OR of ±70 g were used as the reference and the data were cut at ±32, ±16, and at ±8 g in post-processing, before calculating parameters. The results show that the OR influenced the outcomes of all investigated parameters, which were not influenced by tested footwear conditions. The lower ORs were associated with an underestimation error for all biomechanical parameters, which increased noticeably with a decreasing OR. It can be concluded that accelerometers with a minimum OR of ±32 g should be used to avoid inaccurate measurements. |
format | Online Article Text |
id | pubmed-5795747 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-57957472018-02-13 The Effect of the Accelerometer Operating Range on Biomechanical Parameters: Stride Length, Velocity, and Peak Tibial Acceleration during Running Mitschke, Christian Kiesewetter, Pierre Milani, Thomas L. Sensors (Basel) Article Previous studies have used accelerometers with various operating ranges (ORs) when measuring biomechanical parameters. However, it is still unclear whether ORs influence the accuracy of running parameters, and whether the different stiffnesses of footwear midsoles influence this accuracy. The purpose of the present study was to systematically investigate the influence of OR on the accuracy of stride length, running velocity, and on peak tibial acceleration. Twenty-one recreational heel strike runners ran on a 15-m indoor track at self-selected running speeds in three footwear conditions (low to high midsole stiffness). Runners were equipped with an inertial measurement unit (IMU) affixed to the heel cup of the right shoe and with a uniaxial accelerometer at the right tibia. Accelerometers (at the tibia and included in the IMU) with a high OR of ±70 g were used as the reference and the data were cut at ±32, ±16, and at ±8 g in post-processing, before calculating parameters. The results show that the OR influenced the outcomes of all investigated parameters, which were not influenced by tested footwear conditions. The lower ORs were associated with an underestimation error for all biomechanical parameters, which increased noticeably with a decreasing OR. It can be concluded that accelerometers with a minimum OR of ±32 g should be used to avoid inaccurate measurements. MDPI 2018-01-05 /pmc/articles/PMC5795747/ /pubmed/29303986 http://dx.doi.org/10.3390/s18010130 Text en © 2018 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Mitschke, Christian Kiesewetter, Pierre Milani, Thomas L. The Effect of the Accelerometer Operating Range on Biomechanical Parameters: Stride Length, Velocity, and Peak Tibial Acceleration during Running |
title | The Effect of the Accelerometer Operating Range on Biomechanical Parameters: Stride Length, Velocity, and Peak Tibial Acceleration during Running |
title_full | The Effect of the Accelerometer Operating Range on Biomechanical Parameters: Stride Length, Velocity, and Peak Tibial Acceleration during Running |
title_fullStr | The Effect of the Accelerometer Operating Range on Biomechanical Parameters: Stride Length, Velocity, and Peak Tibial Acceleration during Running |
title_full_unstemmed | The Effect of the Accelerometer Operating Range on Biomechanical Parameters: Stride Length, Velocity, and Peak Tibial Acceleration during Running |
title_short | The Effect of the Accelerometer Operating Range on Biomechanical Parameters: Stride Length, Velocity, and Peak Tibial Acceleration during Running |
title_sort | effect of the accelerometer operating range on biomechanical parameters: stride length, velocity, and peak tibial acceleration during running |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5795747/ https://www.ncbi.nlm.nih.gov/pubmed/29303986 http://dx.doi.org/10.3390/s18010130 |
work_keys_str_mv | AT mitschkechristian theeffectoftheaccelerometeroperatingrangeonbiomechanicalparametersstridelengthvelocityandpeaktibialaccelerationduringrunning AT kiesewetterpierre theeffectoftheaccelerometeroperatingrangeonbiomechanicalparametersstridelengthvelocityandpeaktibialaccelerationduringrunning AT milanithomasl theeffectoftheaccelerometeroperatingrangeonbiomechanicalparametersstridelengthvelocityandpeaktibialaccelerationduringrunning AT mitschkechristian effectoftheaccelerometeroperatingrangeonbiomechanicalparametersstridelengthvelocityandpeaktibialaccelerationduringrunning AT kiesewetterpierre effectoftheaccelerometeroperatingrangeonbiomechanicalparametersstridelengthvelocityandpeaktibialaccelerationduringrunning AT milanithomasl effectoftheaccelerometeroperatingrangeonbiomechanicalparametersstridelengthvelocityandpeaktibialaccelerationduringrunning |