Cargando…

Online Removal of Baseline Shift with a Polynomial Function for Hemodynamic Monitoring Using Near-Infrared Spectroscopy

Near-infrared spectroscopy (NIRS) has become widely accepted as a valuable tool for noninvasively monitoring hemodynamics for clinical and diagnostic purposes. Baseline shift has attracted great attention in the field, but there has been little quantitative study on baseline removal. Here, we aimed...

Descripción completa

Detalles Bibliográficos
Autores principales: Zhao, Ke, Ji, Yaoyao, Li, Yan, Li, Ting
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5795942/
https://www.ncbi.nlm.nih.gov/pubmed/29361729
http://dx.doi.org/10.3390/s18010312
_version_ 1783297396118126592
author Zhao, Ke
Ji, Yaoyao
Li, Yan
Li, Ting
author_facet Zhao, Ke
Ji, Yaoyao
Li, Yan
Li, Ting
author_sort Zhao, Ke
collection PubMed
description Near-infrared spectroscopy (NIRS) has become widely accepted as a valuable tool for noninvasively monitoring hemodynamics for clinical and diagnostic purposes. Baseline shift has attracted great attention in the field, but there has been little quantitative study on baseline removal. Here, we aimed to study the baseline characteristics of an in-house-built portable medical NIRS device over a long time (>3.5 h). We found that the measured baselines all formed perfect polynomial functions on phantom tests mimicking human bodies, which were identified by recent NIRS studies. More importantly, our study shows that the fourth-order polynomial function acted to distinguish performance with stable and low-computation-burden fitting calibration (R-square >0.99 for all probes) among second- to sixth-order polynomials, evaluated by the parameters R-square, sum of squares due to error, and residual. This study provides a straightforward, efficient, and quantitatively evaluated solution for online baseline removal for hemodynamic monitoring using NIRS devices.
format Online
Article
Text
id pubmed-5795942
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-57959422018-02-13 Online Removal of Baseline Shift with a Polynomial Function for Hemodynamic Monitoring Using Near-Infrared Spectroscopy Zhao, Ke Ji, Yaoyao Li, Yan Li, Ting Sensors (Basel) Article Near-infrared spectroscopy (NIRS) has become widely accepted as a valuable tool for noninvasively monitoring hemodynamics for clinical and diagnostic purposes. Baseline shift has attracted great attention in the field, but there has been little quantitative study on baseline removal. Here, we aimed to study the baseline characteristics of an in-house-built portable medical NIRS device over a long time (>3.5 h). We found that the measured baselines all formed perfect polynomial functions on phantom tests mimicking human bodies, which were identified by recent NIRS studies. More importantly, our study shows that the fourth-order polynomial function acted to distinguish performance with stable and low-computation-burden fitting calibration (R-square >0.99 for all probes) among second- to sixth-order polynomials, evaluated by the parameters R-square, sum of squares due to error, and residual. This study provides a straightforward, efficient, and quantitatively evaluated solution for online baseline removal for hemodynamic monitoring using NIRS devices. MDPI 2018-01-21 /pmc/articles/PMC5795942/ /pubmed/29361729 http://dx.doi.org/10.3390/s18010312 Text en © 2018 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Zhao, Ke
Ji, Yaoyao
Li, Yan
Li, Ting
Online Removal of Baseline Shift with a Polynomial Function for Hemodynamic Monitoring Using Near-Infrared Spectroscopy
title Online Removal of Baseline Shift with a Polynomial Function for Hemodynamic Monitoring Using Near-Infrared Spectroscopy
title_full Online Removal of Baseline Shift with a Polynomial Function for Hemodynamic Monitoring Using Near-Infrared Spectroscopy
title_fullStr Online Removal of Baseline Shift with a Polynomial Function for Hemodynamic Monitoring Using Near-Infrared Spectroscopy
title_full_unstemmed Online Removal of Baseline Shift with a Polynomial Function for Hemodynamic Monitoring Using Near-Infrared Spectroscopy
title_short Online Removal of Baseline Shift with a Polynomial Function for Hemodynamic Monitoring Using Near-Infrared Spectroscopy
title_sort online removal of baseline shift with a polynomial function for hemodynamic monitoring using near-infrared spectroscopy
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5795942/
https://www.ncbi.nlm.nih.gov/pubmed/29361729
http://dx.doi.org/10.3390/s18010312
work_keys_str_mv AT zhaoke onlineremovalofbaselineshiftwithapolynomialfunctionforhemodynamicmonitoringusingnearinfraredspectroscopy
AT jiyaoyao onlineremovalofbaselineshiftwithapolynomialfunctionforhemodynamicmonitoringusingnearinfraredspectroscopy
AT liyan onlineremovalofbaselineshiftwithapolynomialfunctionforhemodynamicmonitoringusingnearinfraredspectroscopy
AT liting onlineremovalofbaselineshiftwithapolynomialfunctionforhemodynamicmonitoringusingnearinfraredspectroscopy