Cargando…
Accuracy of serum-specific IgE test with microfluidic array enzyme-linked immunosorbent assay for diagnosing inhalant allergen sensitization in asthma and/or rhinitis allergy patients in Jakarta, Indonesia
BACKGROUND: Asthma and allergic rhinitis are a global health burden. Inhalant allergens worsen the symptoms and clinical manifestations of asthma and allergic rhinitis. Skin prick test is the gold standard for diagnosing allergen sensitization but is associated with some limitations. In contrast, in...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Asia Pacific Association of Allergy, Asthma and Clinical Immunology
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5796961/ https://www.ncbi.nlm.nih.gov/pubmed/29423377 http://dx.doi.org/10.5415/apallergy.2018.8.e10 |
_version_ | 1783297577486123008 |
---|---|
author | Sinurat, Julfreser Rengganis, Iris Rumende, Cleopas Martin Harimurti, Kuntjoro |
author_facet | Sinurat, Julfreser Rengganis, Iris Rumende, Cleopas Martin Harimurti, Kuntjoro |
author_sort | Sinurat, Julfreser |
collection | PubMed |
description | BACKGROUND: Asthma and allergic rhinitis are a global health burden. Inhalant allergens worsen the symptoms and clinical manifestations of asthma and allergic rhinitis. Skin prick test is the gold standard for diagnosing allergen sensitization but is associated with some limitations. In contrast, in vitro serum-specific immunoglobulin E (SSIgE) test is convenient and is not associated with an anaphylactic risk. OBJECTIVE: The present study compared the accuracy of the SSIgE test by using microfluidic array enzyme-linked immunosorbent assay (ELISA) with that of the skin prick test for diagnosing inhalant allergen sensitization in patients with asthma and/or allergic rhinitis. METHODS: This diagnostic study included patients with asthma and/or allergic rhinitis. Of these, 100 patients underwent the SSIgE test for diagnosing sensitization to house dust mites (Dermatophagoides pteronyssinus, Dermatophagoides farinae, and Blomia tropicalis), dog dander, cat dander, and cockroach allergen. All the patients also underwent the skin prick test for diagnosing allergen sensitization. The sensitivity, specificity, predictive value, and likelihood ratio (LR) of the SSIgE test were evaluated for each allergen. RESULTS: Sensitivity of the SSIgE test for diagnosing house dust mite sensitization was 48%–77%, with the highest sensitivity (77%) observed for diagnosing D. farinae sensitization. Specificity of the SSIgE test for diagnosing house dust mite sensitization was 64%–95%, with the highest specificity (95%) observed for diagnosing B. tropicalis sensitization. Although the SSIgE test showed high specificity and LR+ for diagnosing cockroach allergen sensitization, it showed low sensitivity (12%). Moreover, the SSIgE test showed high specificity (89%) but low sensitivity (3%) for diagnosing dog dander sensitization and high specificity (88%) but low sensitivity (10%) for diagnosing cat dander sensitization. CONCLUSION: The SSIgE test using microfluidic array ELISA shows moderate accuracy for diagnosing house dust mite sensitization and low accuracy for diagnosing cockroach allergen and dog and cat dander sensitization. |
format | Online Article Text |
id | pubmed-5796961 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | Asia Pacific Association of Allergy, Asthma and Clinical Immunology |
record_format | MEDLINE/PubMed |
spelling | pubmed-57969612018-02-08 Accuracy of serum-specific IgE test with microfluidic array enzyme-linked immunosorbent assay for diagnosing inhalant allergen sensitization in asthma and/or rhinitis allergy patients in Jakarta, Indonesia Sinurat, Julfreser Rengganis, Iris Rumende, Cleopas Martin Harimurti, Kuntjoro Asia Pac Allergy Original Article BACKGROUND: Asthma and allergic rhinitis are a global health burden. Inhalant allergens worsen the symptoms and clinical manifestations of asthma and allergic rhinitis. Skin prick test is the gold standard for diagnosing allergen sensitization but is associated with some limitations. In contrast, in vitro serum-specific immunoglobulin E (SSIgE) test is convenient and is not associated with an anaphylactic risk. OBJECTIVE: The present study compared the accuracy of the SSIgE test by using microfluidic array enzyme-linked immunosorbent assay (ELISA) with that of the skin prick test for diagnosing inhalant allergen sensitization in patients with asthma and/or allergic rhinitis. METHODS: This diagnostic study included patients with asthma and/or allergic rhinitis. Of these, 100 patients underwent the SSIgE test for diagnosing sensitization to house dust mites (Dermatophagoides pteronyssinus, Dermatophagoides farinae, and Blomia tropicalis), dog dander, cat dander, and cockroach allergen. All the patients also underwent the skin prick test for diagnosing allergen sensitization. The sensitivity, specificity, predictive value, and likelihood ratio (LR) of the SSIgE test were evaluated for each allergen. RESULTS: Sensitivity of the SSIgE test for diagnosing house dust mite sensitization was 48%–77%, with the highest sensitivity (77%) observed for diagnosing D. farinae sensitization. Specificity of the SSIgE test for diagnosing house dust mite sensitization was 64%–95%, with the highest specificity (95%) observed for diagnosing B. tropicalis sensitization. Although the SSIgE test showed high specificity and LR+ for diagnosing cockroach allergen sensitization, it showed low sensitivity (12%). Moreover, the SSIgE test showed high specificity (89%) but low sensitivity (3%) for diagnosing dog dander sensitization and high specificity (88%) but low sensitivity (10%) for diagnosing cat dander sensitization. CONCLUSION: The SSIgE test using microfluidic array ELISA shows moderate accuracy for diagnosing house dust mite sensitization and low accuracy for diagnosing cockroach allergen and dog and cat dander sensitization. Asia Pacific Association of Allergy, Asthma and Clinical Immunology 2018-01-30 /pmc/articles/PMC5796961/ /pubmed/29423377 http://dx.doi.org/10.5415/apallergy.2018.8.e10 Text en Copyright © 2018. Asia Pacific Association of Allergy, Asthma and Clinical Immunology. http://creativecommons.org/licenses/by-nc/4.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Article Sinurat, Julfreser Rengganis, Iris Rumende, Cleopas Martin Harimurti, Kuntjoro Accuracy of serum-specific IgE test with microfluidic array enzyme-linked immunosorbent assay for diagnosing inhalant allergen sensitization in asthma and/or rhinitis allergy patients in Jakarta, Indonesia |
title | Accuracy of serum-specific IgE test with microfluidic array enzyme-linked immunosorbent assay for diagnosing inhalant allergen sensitization in asthma and/or rhinitis allergy patients in Jakarta, Indonesia |
title_full | Accuracy of serum-specific IgE test with microfluidic array enzyme-linked immunosorbent assay for diagnosing inhalant allergen sensitization in asthma and/or rhinitis allergy patients in Jakarta, Indonesia |
title_fullStr | Accuracy of serum-specific IgE test with microfluidic array enzyme-linked immunosorbent assay for diagnosing inhalant allergen sensitization in asthma and/or rhinitis allergy patients in Jakarta, Indonesia |
title_full_unstemmed | Accuracy of serum-specific IgE test with microfluidic array enzyme-linked immunosorbent assay for diagnosing inhalant allergen sensitization in asthma and/or rhinitis allergy patients in Jakarta, Indonesia |
title_short | Accuracy of serum-specific IgE test with microfluidic array enzyme-linked immunosorbent assay for diagnosing inhalant allergen sensitization in asthma and/or rhinitis allergy patients in Jakarta, Indonesia |
title_sort | accuracy of serum-specific ige test with microfluidic array enzyme-linked immunosorbent assay for diagnosing inhalant allergen sensitization in asthma and/or rhinitis allergy patients in jakarta, indonesia |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5796961/ https://www.ncbi.nlm.nih.gov/pubmed/29423377 http://dx.doi.org/10.5415/apallergy.2018.8.e10 |
work_keys_str_mv | AT sinuratjulfreser accuracyofserumspecificigetestwithmicrofluidicarrayenzymelinkedimmunosorbentassayfordiagnosinginhalantallergensensitizationinasthmaandorrhinitisallergypatientsinjakartaindonesia AT rengganisiris accuracyofserumspecificigetestwithmicrofluidicarrayenzymelinkedimmunosorbentassayfordiagnosinginhalantallergensensitizationinasthmaandorrhinitisallergypatientsinjakartaindonesia AT rumendecleopasmartin accuracyofserumspecificigetestwithmicrofluidicarrayenzymelinkedimmunosorbentassayfordiagnosinginhalantallergensensitizationinasthmaandorrhinitisallergypatientsinjakartaindonesia AT harimurtikuntjoro accuracyofserumspecificigetestwithmicrofluidicarrayenzymelinkedimmunosorbentassayfordiagnosinginhalantallergensensitizationinasthmaandorrhinitisallergypatientsinjakartaindonesia |