Cargando…
Impact of surgical management in cases of intraoperative membrane perforation during a sinus lift procedure: a follow-up on bone graft stability and implant success
BACKGROUND: Until now, sinus floor elevation represents the gold standard procedure in the atrophic maxilla in order to facilitate dental implant insertion. Although the procedure remains highly predictive, the perforation of the Schneiderian membrane might compromise the stability of the augmented...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer Berlin Heidelberg
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5797725/ https://www.ncbi.nlm.nih.gov/pubmed/29399707 http://dx.doi.org/10.1186/s40729-018-0116-8 |
_version_ | 1783297735889256448 |
---|---|
author | Beck-Broichsitter, Benedicta E. Westhoff, Dorothea Behrens, Eleonore Wiltfang, Jörg Becker, Stephan T. |
author_facet | Beck-Broichsitter, Benedicta E. Westhoff, Dorothea Behrens, Eleonore Wiltfang, Jörg Becker, Stephan T. |
author_sort | Beck-Broichsitter, Benedicta E. |
collection | PubMed |
description | BACKGROUND: Until now, sinus floor elevation represents the gold standard procedure in the atrophic maxilla in order to facilitate dental implant insertion. Although the procedure remains highly predictive, the perforation of the Schneiderian membrane might compromise the stability of the augmented bone and implant success due to chronic sinus infection. The aim of this retrospective cohort study was to show that a membrane tear, if detected and surgically properly addressed, has no influence on the survival of dental implants and bone resorption in the augmented area. METHODS: Thirty-one patients with 39 perforations could be included in this evaluation, and a control group of 32 patients with 40 sinus lift procedures without complications were compared regarding the radiographically determined development of bone level, peri-implant infection, and implant loss. RESULTS: Implant survival was 98.9% in the perforation group over an observation period of 2.7 (± 2.03) years compared to 100% in the control group after 1.8 (± 1.57) years. The residual bone level was significantly lower in the perforation group (p = 0.05) but showed no difference direct postoperatively (p = 0.7851) or in the follow-up assessment (p = 0.2338). Bone resorption remained not different between both groups (p = 0.945). A two-stage procedure was more frequent in the perforation group (p = 0.0003) as well as peri-implantitis (p = 0.0004). CONCLUSIONS: Within the limits of our study, the perforation of the Schneiderian membrane did not have a negative impact on long-term graft stability or the overall implant survival. |
format | Online Article Text |
id | pubmed-5797725 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | Springer Berlin Heidelberg |
record_format | MEDLINE/PubMed |
spelling | pubmed-57977252018-02-09 Impact of surgical management in cases of intraoperative membrane perforation during a sinus lift procedure: a follow-up on bone graft stability and implant success Beck-Broichsitter, Benedicta E. Westhoff, Dorothea Behrens, Eleonore Wiltfang, Jörg Becker, Stephan T. Int J Implant Dent Research BACKGROUND: Until now, sinus floor elevation represents the gold standard procedure in the atrophic maxilla in order to facilitate dental implant insertion. Although the procedure remains highly predictive, the perforation of the Schneiderian membrane might compromise the stability of the augmented bone and implant success due to chronic sinus infection. The aim of this retrospective cohort study was to show that a membrane tear, if detected and surgically properly addressed, has no influence on the survival of dental implants and bone resorption in the augmented area. METHODS: Thirty-one patients with 39 perforations could be included in this evaluation, and a control group of 32 patients with 40 sinus lift procedures without complications were compared regarding the radiographically determined development of bone level, peri-implant infection, and implant loss. RESULTS: Implant survival was 98.9% in the perforation group over an observation period of 2.7 (± 2.03) years compared to 100% in the control group after 1.8 (± 1.57) years. The residual bone level was significantly lower in the perforation group (p = 0.05) but showed no difference direct postoperatively (p = 0.7851) or in the follow-up assessment (p = 0.2338). Bone resorption remained not different between both groups (p = 0.945). A two-stage procedure was more frequent in the perforation group (p = 0.0003) as well as peri-implantitis (p = 0.0004). CONCLUSIONS: Within the limits of our study, the perforation of the Schneiderian membrane did not have a negative impact on long-term graft stability or the overall implant survival. Springer Berlin Heidelberg 2018-02-05 /pmc/articles/PMC5797725/ /pubmed/29399707 http://dx.doi.org/10.1186/s40729-018-0116-8 Text en © The Author(s). 2018 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. |
spellingShingle | Research Beck-Broichsitter, Benedicta E. Westhoff, Dorothea Behrens, Eleonore Wiltfang, Jörg Becker, Stephan T. Impact of surgical management in cases of intraoperative membrane perforation during a sinus lift procedure: a follow-up on bone graft stability and implant success |
title | Impact of surgical management in cases of intraoperative membrane perforation during a sinus lift procedure: a follow-up on bone graft stability and implant success |
title_full | Impact of surgical management in cases of intraoperative membrane perforation during a sinus lift procedure: a follow-up on bone graft stability and implant success |
title_fullStr | Impact of surgical management in cases of intraoperative membrane perforation during a sinus lift procedure: a follow-up on bone graft stability and implant success |
title_full_unstemmed | Impact of surgical management in cases of intraoperative membrane perforation during a sinus lift procedure: a follow-up on bone graft stability and implant success |
title_short | Impact of surgical management in cases of intraoperative membrane perforation during a sinus lift procedure: a follow-up on bone graft stability and implant success |
title_sort | impact of surgical management in cases of intraoperative membrane perforation during a sinus lift procedure: a follow-up on bone graft stability and implant success |
topic | Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5797725/ https://www.ncbi.nlm.nih.gov/pubmed/29399707 http://dx.doi.org/10.1186/s40729-018-0116-8 |
work_keys_str_mv | AT beckbroichsitterbenedictae impactofsurgicalmanagementincasesofintraoperativemembraneperforationduringasinusliftprocedureafollowuponbonegraftstabilityandimplantsuccess AT westhoffdorothea impactofsurgicalmanagementincasesofintraoperativemembraneperforationduringasinusliftprocedureafollowuponbonegraftstabilityandimplantsuccess AT behrenseleonore impactofsurgicalmanagementincasesofintraoperativemembraneperforationduringasinusliftprocedureafollowuponbonegraftstabilityandimplantsuccess AT wiltfangjorg impactofsurgicalmanagementincasesofintraoperativemembraneperforationduringasinusliftprocedureafollowuponbonegraftstabilityandimplantsuccess AT beckerstephant impactofsurgicalmanagementincasesofintraoperativemembraneperforationduringasinusliftprocedureafollowuponbonegraftstabilityandimplantsuccess |