Cargando…

Full-Stokes polarization imaging method based on the self-organized grating array in fused silica

A full-Stokes polarization imaging method based on the self-organized grating array was presented. By focusing the ultra-fast laser with moderate fluence into fused silica, the self-organized grating array was fabricated, featuring the optical properties similar to wave plates. A set of four indepen...

Descripción completa

Detalles Bibliográficos
Autores principales: Xu, Canhua, Ke, Chaozhen, Ma, Jing, Huang, Yantang, Zeng, Zhiping
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Nature Publishing Group UK 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5799200/
https://www.ncbi.nlm.nih.gov/pubmed/29402906
http://dx.doi.org/10.1038/s41598-018-19942-6
_version_ 1783297945190268928
author Xu, Canhua
Ke, Chaozhen
Ma, Jing
Huang, Yantang
Zeng, Zhiping
author_facet Xu, Canhua
Ke, Chaozhen
Ma, Jing
Huang, Yantang
Zeng, Zhiping
author_sort Xu, Canhua
collection PubMed
description A full-Stokes polarization imaging method based on the self-organized grating array was presented. By focusing the ultra-fast laser with moderate fluence into fused silica, the self-organized grating array was fabricated, featuring the optical properties similar to wave plates. A set of four independent polarization measurements were simultaneously acquired with designed grating array mounted in the focal plane of an imaging detector. Experimental results including the device fabrication, calibration and optimization were presented. Finally, a principle verification experiment was implemented for our polarization imaging method.
format Online
Article
Text
id pubmed-5799200
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Nature Publishing Group UK
record_format MEDLINE/PubMed
spelling pubmed-57992002018-02-14 Full-Stokes polarization imaging method based on the self-organized grating array in fused silica Xu, Canhua Ke, Chaozhen Ma, Jing Huang, Yantang Zeng, Zhiping Sci Rep Article A full-Stokes polarization imaging method based on the self-organized grating array was presented. By focusing the ultra-fast laser with moderate fluence into fused silica, the self-organized grating array was fabricated, featuring the optical properties similar to wave plates. A set of four independent polarization measurements were simultaneously acquired with designed grating array mounted in the focal plane of an imaging detector. Experimental results including the device fabrication, calibration and optimization were presented. Finally, a principle verification experiment was implemented for our polarization imaging method. Nature Publishing Group UK 2018-02-05 /pmc/articles/PMC5799200/ /pubmed/29402906 http://dx.doi.org/10.1038/s41598-018-19942-6 Text en © The Author(s) 2018 Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons license and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/.
spellingShingle Article
Xu, Canhua
Ke, Chaozhen
Ma, Jing
Huang, Yantang
Zeng, Zhiping
Full-Stokes polarization imaging method based on the self-organized grating array in fused silica
title Full-Stokes polarization imaging method based on the self-organized grating array in fused silica
title_full Full-Stokes polarization imaging method based on the self-organized grating array in fused silica
title_fullStr Full-Stokes polarization imaging method based on the self-organized grating array in fused silica
title_full_unstemmed Full-Stokes polarization imaging method based on the self-organized grating array in fused silica
title_short Full-Stokes polarization imaging method based on the self-organized grating array in fused silica
title_sort full-stokes polarization imaging method based on the self-organized grating array in fused silica
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5799200/
https://www.ncbi.nlm.nih.gov/pubmed/29402906
http://dx.doi.org/10.1038/s41598-018-19942-6
work_keys_str_mv AT xucanhua fullstokespolarizationimagingmethodbasedontheselforganizedgratingarrayinfusedsilica
AT kechaozhen fullstokespolarizationimagingmethodbasedontheselforganizedgratingarrayinfusedsilica
AT majing fullstokespolarizationimagingmethodbasedontheselforganizedgratingarrayinfusedsilica
AT huangyantang fullstokespolarizationimagingmethodbasedontheselforganizedgratingarrayinfusedsilica
AT zengzhiping fullstokespolarizationimagingmethodbasedontheselforganizedgratingarrayinfusedsilica