Cargando…
A comparative evaluation of fatigue resistance of two different implant overdenture stud attachments with two different denture base materials: An in vitro study
INTRODUCTION: The two implant-supported overdentures have overcome the retention and stability-related problems of conventional mandibular denture. Stud attachments are widely available, less expensive, and easy to use. AIMS AND OBJECTIVES: To determine fatigue resistance of two different stud attac...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Medknow Publications & Media Pvt Ltd
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5799962/ https://www.ncbi.nlm.nih.gov/pubmed/29430136 http://dx.doi.org/10.4103/jips.jips_159_17 |
_version_ | 1783298107523465216 |
---|---|
author | Agrawal, Namrata Jain, Sumeet Agrawal, Deepak |
author_facet | Agrawal, Namrata Jain, Sumeet Agrawal, Deepak |
author_sort | Agrawal, Namrata |
collection | PubMed |
description | INTRODUCTION: The two implant-supported overdentures have overcome the retention and stability-related problems of conventional mandibular denture. Stud attachments are widely available, less expensive, and easy to use. AIMS AND OBJECTIVES: To determine fatigue resistance of two different stud attachments with two denture base materials – autopolymerizing and heat cure acrylic resin till 4320 cycles simulating 03 years of service. MATERIALS AND METHODS: Stud implant overdenture attachments, i.e., ball and socket and Dalla Bona attachments were tightened over the implants in two different mandibular edentulous base models. The housings were incorporated with both direct (chairside) and indirect (laboratory) technique into conventional mandibular dentures. These overdentures were subjected to continuous removal and insertion on Universal Testing Machine till 4320 cycles simulating 3 years of service assuming that patient takes out denture, 4 times in a day. The fatigue resistance was calculated for 0, 1440 (1 year), 2800 (2 years), and 4320 (3 years) cycles. Unpaired and paired t-tests were applied to find the level of significance. RESULTS: Ball and socket attachments housed with heat cure acrylic resin (indirect technique) had the highest values of fatigue resistance at all cycles. Following were Dalla Bona attachments with autopolymerizing acrylic resin (direct technique), ball and socket attachments with autopolymerizing acrylic resin (direct technique), and Dalla Bona attachments with heat cure acrylic resin (indirect technique) as per statistical analysis. CONCLUSION: Two implant-supported mandibular overdenture with ball and socket attachments incorporated by indirect technique showed higher values in terms of retention and absence of disengagement/fracture of components. |
format | Online Article Text |
id | pubmed-5799962 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | Medknow Publications & Media Pvt Ltd |
record_format | MEDLINE/PubMed |
spelling | pubmed-57999622019-01-01 A comparative evaluation of fatigue resistance of two different implant overdenture stud attachments with two different denture base materials: An in vitro study Agrawal, Namrata Jain, Sumeet Agrawal, Deepak J Indian Prosthodont Soc Original Article INTRODUCTION: The two implant-supported overdentures have overcome the retention and stability-related problems of conventional mandibular denture. Stud attachments are widely available, less expensive, and easy to use. AIMS AND OBJECTIVES: To determine fatigue resistance of two different stud attachments with two denture base materials – autopolymerizing and heat cure acrylic resin till 4320 cycles simulating 03 years of service. MATERIALS AND METHODS: Stud implant overdenture attachments, i.e., ball and socket and Dalla Bona attachments were tightened over the implants in two different mandibular edentulous base models. The housings were incorporated with both direct (chairside) and indirect (laboratory) technique into conventional mandibular dentures. These overdentures were subjected to continuous removal and insertion on Universal Testing Machine till 4320 cycles simulating 3 years of service assuming that patient takes out denture, 4 times in a day. The fatigue resistance was calculated for 0, 1440 (1 year), 2800 (2 years), and 4320 (3 years) cycles. Unpaired and paired t-tests were applied to find the level of significance. RESULTS: Ball and socket attachments housed with heat cure acrylic resin (indirect technique) had the highest values of fatigue resistance at all cycles. Following were Dalla Bona attachments with autopolymerizing acrylic resin (direct technique), ball and socket attachments with autopolymerizing acrylic resin (direct technique), and Dalla Bona attachments with heat cure acrylic resin (indirect technique) as per statistical analysis. CONCLUSION: Two implant-supported mandibular overdenture with ball and socket attachments incorporated by indirect technique showed higher values in terms of retention and absence of disengagement/fracture of components. Medknow Publications & Media Pvt Ltd 2018 /pmc/articles/PMC5799962/ /pubmed/29430136 http://dx.doi.org/10.4103/jips.jips_159_17 Text en Copyright: © 2018 The Journal of Indian Prosthodontic Society http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open access article distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 3.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as the author is credited and the new creations are licensed under the identical terms. |
spellingShingle | Original Article Agrawal, Namrata Jain, Sumeet Agrawal, Deepak A comparative evaluation of fatigue resistance of two different implant overdenture stud attachments with two different denture base materials: An in vitro study |
title | A comparative evaluation of fatigue resistance of two different implant overdenture stud attachments with two different denture base materials: An in vitro study |
title_full | A comparative evaluation of fatigue resistance of two different implant overdenture stud attachments with two different denture base materials: An in vitro study |
title_fullStr | A comparative evaluation of fatigue resistance of two different implant overdenture stud attachments with two different denture base materials: An in vitro study |
title_full_unstemmed | A comparative evaluation of fatigue resistance of two different implant overdenture stud attachments with two different denture base materials: An in vitro study |
title_short | A comparative evaluation of fatigue resistance of two different implant overdenture stud attachments with two different denture base materials: An in vitro study |
title_sort | comparative evaluation of fatigue resistance of two different implant overdenture stud attachments with two different denture base materials: an in vitro study |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5799962/ https://www.ncbi.nlm.nih.gov/pubmed/29430136 http://dx.doi.org/10.4103/jips.jips_159_17 |
work_keys_str_mv | AT agrawalnamrata acomparativeevaluationoffatigueresistanceoftwodifferentimplantoverdenturestudattachmentswithtwodifferentdenturebasematerialsaninvitrostudy AT jainsumeet acomparativeevaluationoffatigueresistanceoftwodifferentimplantoverdenturestudattachmentswithtwodifferentdenturebasematerialsaninvitrostudy AT agrawaldeepak acomparativeevaluationoffatigueresistanceoftwodifferentimplantoverdenturestudattachmentswithtwodifferentdenturebasematerialsaninvitrostudy AT agrawalnamrata comparativeevaluationoffatigueresistanceoftwodifferentimplantoverdenturestudattachmentswithtwodifferentdenturebasematerialsaninvitrostudy AT jainsumeet comparativeevaluationoffatigueresistanceoftwodifferentimplantoverdenturestudattachmentswithtwodifferentdenturebasematerialsaninvitrostudy AT agrawaldeepak comparativeevaluationoffatigueresistanceoftwodifferentimplantoverdenturestudattachmentswithtwodifferentdenturebasematerialsaninvitrostudy |