Cargando…
Quick and easy sample preparation without resin embedding for the bone quality assessment of fresh calcified bone using fourier transform infrared imaging
Fourier transform infrared (FTIR) imaging is a powerful tool for the assessment of bone quality; however, it requires the preparation of thin bone sections. Conventional poly(methyl methacrylate) (PMMA) embedding for the preparation of sections takes more than two weeks and causes denaturation of th...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Public Library of Science
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5800566/ https://www.ncbi.nlm.nih.gov/pubmed/29408856 http://dx.doi.org/10.1371/journal.pone.0189650 |
_version_ | 1783298221425033216 |
---|---|
author | Kimura-Suda, Hiromi Takahata, Masahiko Ito, Teppei Shimizu, Tomohiro Kanazawa, Kyosuke Ota, Masahiro Iwasaki, Norimasa |
author_facet | Kimura-Suda, Hiromi Takahata, Masahiko Ito, Teppei Shimizu, Tomohiro Kanazawa, Kyosuke Ota, Masahiro Iwasaki, Norimasa |
author_sort | Kimura-Suda, Hiromi |
collection | PubMed |
description | Fourier transform infrared (FTIR) imaging is a powerful tool for the assessment of bone quality; however, it requires the preparation of thin bone sections. Conventional poly(methyl methacrylate) (PMMA) embedding for the preparation of sections takes more than two weeks and causes denaturation of the bone. Development of a quick and easy sample preparation technique without denaturation is needed for accurate clinical evaluation of fresh calcified bone using FTIR imaging. Frozen sectioning allows the quick and easy preparation of thin sections without denaturation, but it requires a substrate with good chemical resistance and improved heat shock resistance. Polypropylene (PP) film afforded both good chemical resistance and greater heat shock resistance, and the 4-μm-thick PP film coated with glue was thin enough for the IR beam to pass through it, while the optical anisotropy of infrared bands overlapping with PO(4)(3-) band was negligible. The bone quality of femoral thin sections prepared by the conventional PMMA embedding and sectioning procedure (RESIN-S) or the newly developed frozen sectioning procedure (FROZEN-S) was evaluated by FTIR imaging. The mineral-to-matrix ratio and crystallinity in the RESIN-S sections were higher than those in the FROZEN-S sections, whereas the carbonate-to-phosphate ratio in the RESIN-S sections was lower than that in the FROZEN-S sections. In RESIN-S, the increased mineral-to-matrix ratio could be caused by dehydration, and the increased crystallinity and decreased carbonate-to-phosphate ratio might be consequence of dissolution of bone mineral during PMMA embedding. Therefore, the combined use of PP film coated with glue and the frozen sectioning procedure without denaturation appears well suited to the assessment of the bone quality of fresh calcified bone using FTIR imaging. |
format | Online Article Text |
id | pubmed-5800566 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | Public Library of Science |
record_format | MEDLINE/PubMed |
spelling | pubmed-58005662018-02-23 Quick and easy sample preparation without resin embedding for the bone quality assessment of fresh calcified bone using fourier transform infrared imaging Kimura-Suda, Hiromi Takahata, Masahiko Ito, Teppei Shimizu, Tomohiro Kanazawa, Kyosuke Ota, Masahiro Iwasaki, Norimasa PLoS One Research Article Fourier transform infrared (FTIR) imaging is a powerful tool for the assessment of bone quality; however, it requires the preparation of thin bone sections. Conventional poly(methyl methacrylate) (PMMA) embedding for the preparation of sections takes more than two weeks and causes denaturation of the bone. Development of a quick and easy sample preparation technique without denaturation is needed for accurate clinical evaluation of fresh calcified bone using FTIR imaging. Frozen sectioning allows the quick and easy preparation of thin sections without denaturation, but it requires a substrate with good chemical resistance and improved heat shock resistance. Polypropylene (PP) film afforded both good chemical resistance and greater heat shock resistance, and the 4-μm-thick PP film coated with glue was thin enough for the IR beam to pass through it, while the optical anisotropy of infrared bands overlapping with PO(4)(3-) band was negligible. The bone quality of femoral thin sections prepared by the conventional PMMA embedding and sectioning procedure (RESIN-S) or the newly developed frozen sectioning procedure (FROZEN-S) was evaluated by FTIR imaging. The mineral-to-matrix ratio and crystallinity in the RESIN-S sections were higher than those in the FROZEN-S sections, whereas the carbonate-to-phosphate ratio in the RESIN-S sections was lower than that in the FROZEN-S sections. In RESIN-S, the increased mineral-to-matrix ratio could be caused by dehydration, and the increased crystallinity and decreased carbonate-to-phosphate ratio might be consequence of dissolution of bone mineral during PMMA embedding. Therefore, the combined use of PP film coated with glue and the frozen sectioning procedure without denaturation appears well suited to the assessment of the bone quality of fresh calcified bone using FTIR imaging. Public Library of Science 2018-02-06 /pmc/articles/PMC5800566/ /pubmed/29408856 http://dx.doi.org/10.1371/journal.pone.0189650 Text en © 2018 Kimura-Suda et al http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. |
spellingShingle | Research Article Kimura-Suda, Hiromi Takahata, Masahiko Ito, Teppei Shimizu, Tomohiro Kanazawa, Kyosuke Ota, Masahiro Iwasaki, Norimasa Quick and easy sample preparation without resin embedding for the bone quality assessment of fresh calcified bone using fourier transform infrared imaging |
title | Quick and easy sample preparation without resin embedding for the bone quality assessment of fresh calcified bone using fourier transform infrared imaging |
title_full | Quick and easy sample preparation without resin embedding for the bone quality assessment of fresh calcified bone using fourier transform infrared imaging |
title_fullStr | Quick and easy sample preparation without resin embedding for the bone quality assessment of fresh calcified bone using fourier transform infrared imaging |
title_full_unstemmed | Quick and easy sample preparation without resin embedding for the bone quality assessment of fresh calcified bone using fourier transform infrared imaging |
title_short | Quick and easy sample preparation without resin embedding for the bone quality assessment of fresh calcified bone using fourier transform infrared imaging |
title_sort | quick and easy sample preparation without resin embedding for the bone quality assessment of fresh calcified bone using fourier transform infrared imaging |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5800566/ https://www.ncbi.nlm.nih.gov/pubmed/29408856 http://dx.doi.org/10.1371/journal.pone.0189650 |
work_keys_str_mv | AT kimurasudahiromi quickandeasysamplepreparationwithoutresinembeddingforthebonequalityassessmentoffreshcalcifiedboneusingfouriertransforminfraredimaging AT takahatamasahiko quickandeasysamplepreparationwithoutresinembeddingforthebonequalityassessmentoffreshcalcifiedboneusingfouriertransforminfraredimaging AT itoteppei quickandeasysamplepreparationwithoutresinembeddingforthebonequalityassessmentoffreshcalcifiedboneusingfouriertransforminfraredimaging AT shimizutomohiro quickandeasysamplepreparationwithoutresinembeddingforthebonequalityassessmentoffreshcalcifiedboneusingfouriertransforminfraredimaging AT kanazawakyosuke quickandeasysamplepreparationwithoutresinembeddingforthebonequalityassessmentoffreshcalcifiedboneusingfouriertransforminfraredimaging AT otamasahiro quickandeasysamplepreparationwithoutresinembeddingforthebonequalityassessmentoffreshcalcifiedboneusingfouriertransforminfraredimaging AT iwasakinorimasa quickandeasysamplepreparationwithoutresinembeddingforthebonequalityassessmentoffreshcalcifiedboneusingfouriertransforminfraredimaging |