Cargando…

Myopic Shift after Implantation of a Novel Diffractive Trifocal Intraocular Lens in Korean Eyes

PURPOSE: To evaluate the clinical outcomes of cataract surgery using novel diffractive trifocal intraocular lenses (IOLs) in Koreans. METHODS: This was a retrospective, consecutive, interventional study of cataract surgery using POD FineVision IOL implantation. Complete ophthalmologic examinations w...

Descripción completa

Detalles Bibliográficos
Autores principales: Hwang, Sungsoon, Lim, Dong Hui, Hyun, Joo, Kim, Myoung Joon, Chung, Tae-Young
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Korean Ophthalmological Society 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5801085/
https://www.ncbi.nlm.nih.gov/pubmed/29376228
http://dx.doi.org/10.3341/kjo.2017.0060
_version_ 1783298290120392704
author Hwang, Sungsoon
Lim, Dong Hui
Hyun, Joo
Kim, Myoung Joon
Chung, Tae-Young
author_facet Hwang, Sungsoon
Lim, Dong Hui
Hyun, Joo
Kim, Myoung Joon
Chung, Tae-Young
author_sort Hwang, Sungsoon
collection PubMed
description PURPOSE: To evaluate the clinical outcomes of cataract surgery using novel diffractive trifocal intraocular lenses (IOLs) in Koreans. METHODS: This was a retrospective, consecutive, interventional study of cataract surgery using POD FineVision IOL implantation. Complete ophthalmologic examinations were performed preoperatively and postoperatively. Defocus curves were assessed over a range of +1.5 to −4.0 diopters in 0.5-diopter steps at one month postoperatively. Uncorrected distant visual acuity, uncorrected intermediate visual acuity, uncorrected near visual acuity, corrected distant visual acuity, distant-corrected intermediate visual acuity, and distant-corrected near visual acuity were assessed one month postoperatively, and manifest refraction was performed during every visit. RESULTS: The study analyzed 31 eyes in 20 patients. There were statistically significant improvements in uncorrected distance visual acuity, uncorrected intermediate visual acuity, uncorrected near visual acuity, corrected distance visual acuity, distance-corrected intermediate visual acuity, and distance-corrected near visual acuity (p < 0.001). The final postoperative refractive outcomes showed statistically significant myopic shifts compared to the target refraction based on SRK/T, SRK-II, Haigis, and Hoffer Q formulas (p < 0.001). CONCLUSIONS: POD FineVision IOLs provide stable visual restoration with improvements of near and intermediate vision in presbyopic eyes. POD FineVision IOLs show myopic shift in a Korean population; therefore, surgeons should be cautious when selecting IOL power in such patients.
format Online
Article
Text
id pubmed-5801085
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher The Korean Ophthalmological Society
record_format MEDLINE/PubMed
spelling pubmed-58010852018-02-08 Myopic Shift after Implantation of a Novel Diffractive Trifocal Intraocular Lens in Korean Eyes Hwang, Sungsoon Lim, Dong Hui Hyun, Joo Kim, Myoung Joon Chung, Tae-Young Korean J Ophthalmol Original Article PURPOSE: To evaluate the clinical outcomes of cataract surgery using novel diffractive trifocal intraocular lenses (IOLs) in Koreans. METHODS: This was a retrospective, consecutive, interventional study of cataract surgery using POD FineVision IOL implantation. Complete ophthalmologic examinations were performed preoperatively and postoperatively. Defocus curves were assessed over a range of +1.5 to −4.0 diopters in 0.5-diopter steps at one month postoperatively. Uncorrected distant visual acuity, uncorrected intermediate visual acuity, uncorrected near visual acuity, corrected distant visual acuity, distant-corrected intermediate visual acuity, and distant-corrected near visual acuity were assessed one month postoperatively, and manifest refraction was performed during every visit. RESULTS: The study analyzed 31 eyes in 20 patients. There were statistically significant improvements in uncorrected distance visual acuity, uncorrected intermediate visual acuity, uncorrected near visual acuity, corrected distance visual acuity, distance-corrected intermediate visual acuity, and distance-corrected near visual acuity (p < 0.001). The final postoperative refractive outcomes showed statistically significant myopic shifts compared to the target refraction based on SRK/T, SRK-II, Haigis, and Hoffer Q formulas (p < 0.001). CONCLUSIONS: POD FineVision IOLs provide stable visual restoration with improvements of near and intermediate vision in presbyopic eyes. POD FineVision IOLs show myopic shift in a Korean population; therefore, surgeons should be cautious when selecting IOL power in such patients. The Korean Ophthalmological Society 2018-02 2018-01-24 /pmc/articles/PMC5801085/ /pubmed/29376228 http://dx.doi.org/10.3341/kjo.2017.0060 Text en © 2018 The Korean Ophthalmological Society http://creativecommons.org/licenses/by-nc/3.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Hwang, Sungsoon
Lim, Dong Hui
Hyun, Joo
Kim, Myoung Joon
Chung, Tae-Young
Myopic Shift after Implantation of a Novel Diffractive Trifocal Intraocular Lens in Korean Eyes
title Myopic Shift after Implantation of a Novel Diffractive Trifocal Intraocular Lens in Korean Eyes
title_full Myopic Shift after Implantation of a Novel Diffractive Trifocal Intraocular Lens in Korean Eyes
title_fullStr Myopic Shift after Implantation of a Novel Diffractive Trifocal Intraocular Lens in Korean Eyes
title_full_unstemmed Myopic Shift after Implantation of a Novel Diffractive Trifocal Intraocular Lens in Korean Eyes
title_short Myopic Shift after Implantation of a Novel Diffractive Trifocal Intraocular Lens in Korean Eyes
title_sort myopic shift after implantation of a novel diffractive trifocal intraocular lens in korean eyes
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5801085/
https://www.ncbi.nlm.nih.gov/pubmed/29376228
http://dx.doi.org/10.3341/kjo.2017.0060
work_keys_str_mv AT hwangsungsoon myopicshiftafterimplantationofanoveldiffractivetrifocalintraocularlensinkoreaneyes
AT limdonghui myopicshiftafterimplantationofanoveldiffractivetrifocalintraocularlensinkoreaneyes
AT hyunjoo myopicshiftafterimplantationofanoveldiffractivetrifocalintraocularlensinkoreaneyes
AT kimmyoungjoon myopicshiftafterimplantationofanoveldiffractivetrifocalintraocularlensinkoreaneyes
AT chungtaeyoung myopicshiftafterimplantationofanoveldiffractivetrifocalintraocularlensinkoreaneyes