Cargando…

Effects of transcatheter aortic valve implantation on ascending aorta wall elastic properties: Tissue Doppler imaging and strain Doppler echocardiography study()

BACKGROUND: Aortic elastic properties are determinants of left ventricular function by means of ventriculo-arterial coupling and indicators of cardiovascular risk. Aortic valve stenosis surgical replacement temporary reduces aortic function damaging vasa vasorum, while transcatheter aortic valve imp...

Descripción completa

Detalles Bibliográficos
Autores principales: Vizzardi, Enrico, Sciatti, Edoardo, Bonadei, Ivano, D'Aloia, Antonio, Gelsomino, Sandro, Lorusso, Roberto, Ettori, Federica, Metra, Marco
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2014
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5801439/
https://www.ncbi.nlm.nih.gov/pubmed/29450189
http://dx.doi.org/10.1016/j.ijchv.2014.04.003
_version_ 1783298351148564480
author Vizzardi, Enrico
Sciatti, Edoardo
Bonadei, Ivano
D'Aloia, Antonio
Gelsomino, Sandro
Lorusso, Roberto
Ettori, Federica
Metra, Marco
author_facet Vizzardi, Enrico
Sciatti, Edoardo
Bonadei, Ivano
D'Aloia, Antonio
Gelsomino, Sandro
Lorusso, Roberto
Ettori, Federica
Metra, Marco
author_sort Vizzardi, Enrico
collection PubMed
description BACKGROUND: Aortic elastic properties are determinants of left ventricular function by means of ventriculo-arterial coupling and indicators of cardiovascular risk. Aortic valve stenosis surgical replacement temporary reduces aortic function damaging vasa vasorum, while transcatheter aortic valve implantation (TAVI) does not influence it in the short term. We studied aortic distensibility, stiffness, M-mode strain and tissue strain after 6 and 12 months from TAVI. METHODS: We enrolled 15 patients with symptomatic severe aortic stenosis who underwent CoreValve prosthesis (Medtronic, Minneapolis, MN) implantation. Everyone had blood pressure measurement and echocardiography registration before TAVI and after 6 and 12 months. RESULTS: After TAVI NYHA class (p = 0.016), peak and mean aortic valve gradients (p < 0.001 for both) improved. Aortic distensibility increased (p = 0.032 in the first 6 months, p = 0.005 in the second 6 months, and p = 0.003 from baseline to 12 months), as well as stiffness decreased (p = 0.034; 0.090; 0.001), M-mode strain and tissue strain ameliorated (p = 0.041; 0.004; 0.004; and p = 0.013; 0.002; 0.001, respectively), tissue Doppler imaging improved (S′ wave: p = 0.289; 0.347; 0.018. E′ wave: p = 0.018; 0.113; 0.007. A′ wave: p = 0.002; 0.532; 0.001). Moreover, some left ventricular parameters improved at 6 months, such as ejection fraction (from 49 ± 16 to 57 ± 11%; p = 0.044) and diastolic interventricular septum thickness (from 14 ± 2 to 12 ± 2 mm; p = 0.010). Even systolic pulmonary artery pressure (p = 0.019) and left diastolic dysfunction grade ameliorated (p = 0.042). CONCLUSIONS: For the first time we demonstrated that aortic elastic properties improve at 6 and 12 months after TAVI, thus influencing ventriculo-arterial coupling and ameliorating left ventricular function.
format Online
Article
Text
id pubmed-5801439
institution National Center for Biotechnology Information
language English
publishDate 2014
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-58014392018-02-15 Effects of transcatheter aortic valve implantation on ascending aorta wall elastic properties: Tissue Doppler imaging and strain Doppler echocardiography study() Vizzardi, Enrico Sciatti, Edoardo Bonadei, Ivano D'Aloia, Antonio Gelsomino, Sandro Lorusso, Roberto Ettori, Federica Metra, Marco Int J Cardiol Heart Vessel Article BACKGROUND: Aortic elastic properties are determinants of left ventricular function by means of ventriculo-arterial coupling and indicators of cardiovascular risk. Aortic valve stenosis surgical replacement temporary reduces aortic function damaging vasa vasorum, while transcatheter aortic valve implantation (TAVI) does not influence it in the short term. We studied aortic distensibility, stiffness, M-mode strain and tissue strain after 6 and 12 months from TAVI. METHODS: We enrolled 15 patients with symptomatic severe aortic stenosis who underwent CoreValve prosthesis (Medtronic, Minneapolis, MN) implantation. Everyone had blood pressure measurement and echocardiography registration before TAVI and after 6 and 12 months. RESULTS: After TAVI NYHA class (p = 0.016), peak and mean aortic valve gradients (p < 0.001 for both) improved. Aortic distensibility increased (p = 0.032 in the first 6 months, p = 0.005 in the second 6 months, and p = 0.003 from baseline to 12 months), as well as stiffness decreased (p = 0.034; 0.090; 0.001), M-mode strain and tissue strain ameliorated (p = 0.041; 0.004; 0.004; and p = 0.013; 0.002; 0.001, respectively), tissue Doppler imaging improved (S′ wave: p = 0.289; 0.347; 0.018. E′ wave: p = 0.018; 0.113; 0.007. A′ wave: p = 0.002; 0.532; 0.001). Moreover, some left ventricular parameters improved at 6 months, such as ejection fraction (from 49 ± 16 to 57 ± 11%; p = 0.044) and diastolic interventricular septum thickness (from 14 ± 2 to 12 ± 2 mm; p = 0.010). Even systolic pulmonary artery pressure (p = 0.019) and left diastolic dysfunction grade ameliorated (p = 0.042). CONCLUSIONS: For the first time we demonstrated that aortic elastic properties improve at 6 and 12 months after TAVI, thus influencing ventriculo-arterial coupling and ameliorating left ventricular function. Elsevier 2014-04-26 /pmc/articles/PMC5801439/ /pubmed/29450189 http://dx.doi.org/10.1016/j.ijchv.2014.04.003 Text en © 2014 The Authors http://creativecommons.org/licenses/by-nc-nd/3.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/3.0/).
spellingShingle Article
Vizzardi, Enrico
Sciatti, Edoardo
Bonadei, Ivano
D'Aloia, Antonio
Gelsomino, Sandro
Lorusso, Roberto
Ettori, Federica
Metra, Marco
Effects of transcatheter aortic valve implantation on ascending aorta wall elastic properties: Tissue Doppler imaging and strain Doppler echocardiography study()
title Effects of transcatheter aortic valve implantation on ascending aorta wall elastic properties: Tissue Doppler imaging and strain Doppler echocardiography study()
title_full Effects of transcatheter aortic valve implantation on ascending aorta wall elastic properties: Tissue Doppler imaging and strain Doppler echocardiography study()
title_fullStr Effects of transcatheter aortic valve implantation on ascending aorta wall elastic properties: Tissue Doppler imaging and strain Doppler echocardiography study()
title_full_unstemmed Effects of transcatheter aortic valve implantation on ascending aorta wall elastic properties: Tissue Doppler imaging and strain Doppler echocardiography study()
title_short Effects of transcatheter aortic valve implantation on ascending aorta wall elastic properties: Tissue Doppler imaging and strain Doppler echocardiography study()
title_sort effects of transcatheter aortic valve implantation on ascending aorta wall elastic properties: tissue doppler imaging and strain doppler echocardiography study()
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5801439/
https://www.ncbi.nlm.nih.gov/pubmed/29450189
http://dx.doi.org/10.1016/j.ijchv.2014.04.003
work_keys_str_mv AT vizzardienrico effectsoftranscatheteraorticvalveimplantationonascendingaortawallelasticpropertiestissuedopplerimagingandstraindopplerechocardiographystudy
AT sciattiedoardo effectsoftranscatheteraorticvalveimplantationonascendingaortawallelasticpropertiestissuedopplerimagingandstraindopplerechocardiographystudy
AT bonadeiivano effectsoftranscatheteraorticvalveimplantationonascendingaortawallelasticpropertiestissuedopplerimagingandstraindopplerechocardiographystudy
AT daloiaantonio effectsoftranscatheteraorticvalveimplantationonascendingaortawallelasticpropertiestissuedopplerimagingandstraindopplerechocardiographystudy
AT gelsominosandro effectsoftranscatheteraorticvalveimplantationonascendingaortawallelasticpropertiestissuedopplerimagingandstraindopplerechocardiographystudy
AT lorussoroberto effectsoftranscatheteraorticvalveimplantationonascendingaortawallelasticpropertiestissuedopplerimagingandstraindopplerechocardiographystudy
AT ettorifederica effectsoftranscatheteraorticvalveimplantationonascendingaortawallelasticpropertiestissuedopplerimagingandstraindopplerechocardiographystudy
AT metramarco effectsoftranscatheteraorticvalveimplantationonascendingaortawallelasticpropertiestissuedopplerimagingandstraindopplerechocardiographystudy