Test–Retest Reproducibility of the Microperimeter MP3 With Fundus Image Tracking in Healthy Subjects and Patients With Macular Disease

PURPOSE: To evaluate the test–retest reproducibility of a novel microperimeter with fundus image tracking (MP3, Nidek Co, Japan) in healthy subjects and patients with macular disease. METHODS: Ten healthy subjects and 20 patients suffering from range of macular diseases were included. After training...

Descripción completa

Detalles Bibliográficos
Autores principales: Palkovits, Stefan, Hirnschall, Nino, Georgiev, Stefan, Leisser, Christoph, Findl, Oliver
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Association for Research in Vision and Ophthalmology 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5804295/
https://www.ncbi.nlm.nih.gov/pubmed/29430338
http://dx.doi.org/10.1167/tvst.7.1.17
_version_ 1783298818375155712
author Palkovits, Stefan
Hirnschall, Nino
Georgiev, Stefan
Leisser, Christoph
Findl, Oliver
author_facet Palkovits, Stefan
Hirnschall, Nino
Georgiev, Stefan
Leisser, Christoph
Findl, Oliver
author_sort Palkovits, Stefan
collection PubMed
description PURPOSE: To evaluate the test–retest reproducibility of a novel microperimeter with fundus image tracking (MP3, Nidek Co, Japan) in healthy subjects and patients with macular disease. METHODS: Ten healthy subjects and 20 patients suffering from range of macular diseases were included. After training measurements, two additional microperimetry measurements were scheduled. Test–retest reproducibility was assessed for mean retinal sensitivity, pointwise sensitivity, and deep scotoma size using the coefficient of repeatability and Bland-Altman diagrams. In addition, in a subgroup of patients microperimetry was compared with conventional perimetry. RESULTS: Average differences in mean retinal sensitivity between the two study measurements were 0.26 ± 1.7 dB (median 0 dB; interquartile range [IQR] −1 to 1) for the healthy and 0.36 ± 2.5 dB (median 0 dB; IQR −1 to 2) for the macular patient group. Coefficients of repeatability for mean retinal sensitivity and pointwise retinal sensitivity were 1.2 and 3.3 dB for the healthy subjects and 1.6 and 5.0 dB for the macular disease patients, respectively. Absolute agreement in deep scotoma size between both study days was found in 79.9% of the test loci. CONCLUSION: The microperimeter MP3 shows an adequate test–retest reproducibility for mean retinal sensitivity, pointwise retinal sensitivity, and deep scotoma size in healthy subjects and patients suffering from macular disease. Furthermore, reproducibility of microperimetry is higher than conventional perimetry. TRANSLATIONAL RELEVANCE: Reproducibility is an important measure for each diagnostic device. Especially in a clinical setting high reproducibility set the basis to achieve reliable results using the specific device. Therefore, assessment of the reproducibility is of eminent importance to interpret the findings of future studies.
format Online
Article
Text
id pubmed-5804295
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher The Association for Research in Vision and Ophthalmology
record_format MEDLINE/PubMed
spelling pubmed-58042952018-02-09 Test–Retest Reproducibility of the Microperimeter MP3 With Fundus Image Tracking in Healthy Subjects and Patients With Macular Disease Palkovits, Stefan Hirnschall, Nino Georgiev, Stefan Leisser, Christoph Findl, Oliver Transl Vis Sci Technol Articles PURPOSE: To evaluate the test–retest reproducibility of a novel microperimeter with fundus image tracking (MP3, Nidek Co, Japan) in healthy subjects and patients with macular disease. METHODS: Ten healthy subjects and 20 patients suffering from range of macular diseases were included. After training measurements, two additional microperimetry measurements were scheduled. Test–retest reproducibility was assessed for mean retinal sensitivity, pointwise sensitivity, and deep scotoma size using the coefficient of repeatability and Bland-Altman diagrams. In addition, in a subgroup of patients microperimetry was compared with conventional perimetry. RESULTS: Average differences in mean retinal sensitivity between the two study measurements were 0.26 ± 1.7 dB (median 0 dB; interquartile range [IQR] −1 to 1) for the healthy and 0.36 ± 2.5 dB (median 0 dB; IQR −1 to 2) for the macular patient group. Coefficients of repeatability for mean retinal sensitivity and pointwise retinal sensitivity were 1.2 and 3.3 dB for the healthy subjects and 1.6 and 5.0 dB for the macular disease patients, respectively. Absolute agreement in deep scotoma size between both study days was found in 79.9% of the test loci. CONCLUSION: The microperimeter MP3 shows an adequate test–retest reproducibility for mean retinal sensitivity, pointwise retinal sensitivity, and deep scotoma size in healthy subjects and patients suffering from macular disease. Furthermore, reproducibility of microperimetry is higher than conventional perimetry. TRANSLATIONAL RELEVANCE: Reproducibility is an important measure for each diagnostic device. Especially in a clinical setting high reproducibility set the basis to achieve reliable results using the specific device. Therefore, assessment of the reproducibility is of eminent importance to interpret the findings of future studies. The Association for Research in Vision and Ophthalmology 2018-02-07 /pmc/articles/PMC5804295/ /pubmed/29430338 http://dx.doi.org/10.1167/tvst.7.1.17 Text en Copyright 2018 The Authors http://creativecommons.org/licenses/by/4.0/ This work is licensed under a Creative Commons Attribution 4.0 International License.
spellingShingle Articles
Palkovits, Stefan
Hirnschall, Nino
Georgiev, Stefan
Leisser, Christoph
Findl, Oliver
Test–Retest Reproducibility of the Microperimeter MP3 With Fundus Image Tracking in Healthy Subjects and Patients With Macular Disease
title Test–Retest Reproducibility of the Microperimeter MP3 With Fundus Image Tracking in Healthy Subjects and Patients With Macular Disease
title_full Test–Retest Reproducibility of the Microperimeter MP3 With Fundus Image Tracking in Healthy Subjects and Patients With Macular Disease
title_fullStr Test–Retest Reproducibility of the Microperimeter MP3 With Fundus Image Tracking in Healthy Subjects and Patients With Macular Disease
title_full_unstemmed Test–Retest Reproducibility of the Microperimeter MP3 With Fundus Image Tracking in Healthy Subjects and Patients With Macular Disease
title_short Test–Retest Reproducibility of the Microperimeter MP3 With Fundus Image Tracking in Healthy Subjects and Patients With Macular Disease
title_sort test–retest reproducibility of the microperimeter mp3 with fundus image tracking in healthy subjects and patients with macular disease
topic Articles
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5804295/
https://www.ncbi.nlm.nih.gov/pubmed/29430338
http://dx.doi.org/10.1167/tvst.7.1.17
work_keys_str_mv AT palkovitsstefan testretestreproducibilityofthemicroperimetermp3withfundusimagetrackinginhealthysubjectsandpatientswithmaculardisease
AT hirnschallnino testretestreproducibilityofthemicroperimetermp3withfundusimagetrackinginhealthysubjectsandpatientswithmaculardisease
AT georgievstefan testretestreproducibilityofthemicroperimetermp3withfundusimagetrackinginhealthysubjectsandpatientswithmaculardisease
AT leisserchristoph testretestreproducibilityofthemicroperimetermp3withfundusimagetrackinginhealthysubjectsandpatientswithmaculardisease
AT findloliver testretestreproducibilityofthemicroperimetermp3withfundusimagetrackinginhealthysubjectsandpatientswithmaculardisease