Cargando…

Assessment of the accuracy of portable monitors for halitosis evaluation in subjects without malodor complaint. Are they reliable for clinical practice?

Halitosis is defined as a foul odor emanated from the oral cavity, with great impact in quality of life and social restraints. Recently, the use of Breath Alert™ in research increased significantly. Halimeter™, another portable device, is often used in clinical practice. Nevertheless, not many studi...

Descripción completa

Detalles Bibliográficos
Autores principales: Falcão, Denise Pinheiro, Miranda, Priscila Carvalho, Almeida, Tayana Filgueira Galdino, Scalco, Monique Gomes da Silva, Fregni, Felipe, de Amorim, Rivadávio Fernandes Batista
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Faculdade De Odontologia De Bauru - USP 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5804393/
https://www.ncbi.nlm.nih.gov/pubmed/29069154
http://dx.doi.org/10.1590/1678-7757-2016-0305
_version_ 1783298837431975936
author Falcão, Denise Pinheiro
Miranda, Priscila Carvalho
Almeida, Tayana Filgueira Galdino
Scalco, Monique Gomes da Silva
Fregni, Felipe
de Amorim, Rivadávio Fernandes Batista
author_facet Falcão, Denise Pinheiro
Miranda, Priscila Carvalho
Almeida, Tayana Filgueira Galdino
Scalco, Monique Gomes da Silva
Fregni, Felipe
de Amorim, Rivadávio Fernandes Batista
author_sort Falcão, Denise Pinheiro
collection PubMed
description Halitosis is defined as a foul odor emanated from the oral cavity, with great impact in quality of life and social restraints. Recently, the use of Breath Alert™ in research increased significantly. Halimeter™, another portable device, is often used in clinical practice. Nevertheless, not many studies have verified the accuracy and compared the results of both devices simultaneously. Objective: To verify the accuracy of Breath Alert™ and Halimeter™ in patients without chief complaint of halitosis, using the organoleptic test (OT) as "gold standard." The second aim was to verify whether their concomitant use could enhance the diagnostic accuracy of halitosis. Material and Methods: A cross-sectional analytical study was performed. The quality of expired air of 34 subjects without chief complaint of halitosis was assessed. Two experienced examiners carried out the OT. Afterward, a third blinded examiner performed Halimeter™ (HT) and Breath Alert™ (BA) tests. Results: The OT identified halitosis in 21 subjects (62%). The area under the ROC curve (95% confidence interval) was 0.67 (0.48-0.85) and 0.54 (0.34-0.75) for HT and BA, respectively. The accuracy for HT and BA was 59% and 47%, respectively. The combined usage of HT and BA provided 11 positive results, being 9 subjects (43%) out of the total of 21 positive cases. Conclusions: Halimeter™ and Breath Alert™ were not able to diagnose halitosis in non-complainer subjects at the same level as the organoleptic examination, since their accuracy were low. Our results suggest that such portable devices are not reliable tools to assess halitosis and may neglect or misdiagnose a considerable number of patients in clinical practice.
format Online
Article
Text
id pubmed-5804393
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher Faculdade De Odontologia De Bauru - USP
record_format MEDLINE/PubMed
spelling pubmed-58043932018-02-14 Assessment of the accuracy of portable monitors for halitosis evaluation in subjects without malodor complaint. Are they reliable for clinical practice? Falcão, Denise Pinheiro Miranda, Priscila Carvalho Almeida, Tayana Filgueira Galdino Scalco, Monique Gomes da Silva Fregni, Felipe de Amorim, Rivadávio Fernandes Batista J Appl Oral Sci Original Article Halitosis is defined as a foul odor emanated from the oral cavity, with great impact in quality of life and social restraints. Recently, the use of Breath Alert™ in research increased significantly. Halimeter™, another portable device, is often used in clinical practice. Nevertheless, not many studies have verified the accuracy and compared the results of both devices simultaneously. Objective: To verify the accuracy of Breath Alert™ and Halimeter™ in patients without chief complaint of halitosis, using the organoleptic test (OT) as "gold standard." The second aim was to verify whether their concomitant use could enhance the diagnostic accuracy of halitosis. Material and Methods: A cross-sectional analytical study was performed. The quality of expired air of 34 subjects without chief complaint of halitosis was assessed. Two experienced examiners carried out the OT. Afterward, a third blinded examiner performed Halimeter™ (HT) and Breath Alert™ (BA) tests. Results: The OT identified halitosis in 21 subjects (62%). The area under the ROC curve (95% confidence interval) was 0.67 (0.48-0.85) and 0.54 (0.34-0.75) for HT and BA, respectively. The accuracy for HT and BA was 59% and 47%, respectively. The combined usage of HT and BA provided 11 positive results, being 9 subjects (43%) out of the total of 21 positive cases. Conclusions: Halimeter™ and Breath Alert™ were not able to diagnose halitosis in non-complainer subjects at the same level as the organoleptic examination, since their accuracy were low. Our results suggest that such portable devices are not reliable tools to assess halitosis and may neglect or misdiagnose a considerable number of patients in clinical practice. Faculdade De Odontologia De Bauru - USP 2017 /pmc/articles/PMC5804393/ /pubmed/29069154 http://dx.doi.org/10.1590/1678-7757-2016-0305 Text en https://creativecommons.org/licenses/by/4.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Falcão, Denise Pinheiro
Miranda, Priscila Carvalho
Almeida, Tayana Filgueira Galdino
Scalco, Monique Gomes da Silva
Fregni, Felipe
de Amorim, Rivadávio Fernandes Batista
Assessment of the accuracy of portable monitors for halitosis evaluation in subjects without malodor complaint. Are they reliable for clinical practice?
title Assessment of the accuracy of portable monitors for halitosis evaluation in subjects without malodor complaint. Are they reliable for clinical practice?
title_full Assessment of the accuracy of portable monitors for halitosis evaluation in subjects without malodor complaint. Are they reliable for clinical practice?
title_fullStr Assessment of the accuracy of portable monitors for halitosis evaluation in subjects without malodor complaint. Are they reliable for clinical practice?
title_full_unstemmed Assessment of the accuracy of portable monitors for halitosis evaluation in subjects without malodor complaint. Are they reliable for clinical practice?
title_short Assessment of the accuracy of portable monitors for halitosis evaluation in subjects without malodor complaint. Are they reliable for clinical practice?
title_sort assessment of the accuracy of portable monitors for halitosis evaluation in subjects without malodor complaint. are they reliable for clinical practice?
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5804393/
https://www.ncbi.nlm.nih.gov/pubmed/29069154
http://dx.doi.org/10.1590/1678-7757-2016-0305
work_keys_str_mv AT falcaodenisepinheiro assessmentoftheaccuracyofportablemonitorsforhalitosisevaluationinsubjectswithoutmalodorcomplaintaretheyreliableforclinicalpractice
AT mirandapriscilacarvalho assessmentoftheaccuracyofportablemonitorsforhalitosisevaluationinsubjectswithoutmalodorcomplaintaretheyreliableforclinicalpractice
AT almeidatayanafilgueiragaldino assessmentoftheaccuracyofportablemonitorsforhalitosisevaluationinsubjectswithoutmalodorcomplaintaretheyreliableforclinicalpractice
AT scalcomoniquegomesdasilva assessmentoftheaccuracyofportablemonitorsforhalitosisevaluationinsubjectswithoutmalodorcomplaintaretheyreliableforclinicalpractice
AT fregnifelipe assessmentoftheaccuracyofportablemonitorsforhalitosisevaluationinsubjectswithoutmalodorcomplaintaretheyreliableforclinicalpractice
AT deamorimrivadaviofernandesbatista assessmentoftheaccuracyofportablemonitorsforhalitosisevaluationinsubjectswithoutmalodorcomplaintaretheyreliableforclinicalpractice