Cargando…

Endovascular repair with extracorporeal membrane oxygenation as a rescue strategy for aortobronchial fistula: a case report

Aortobronchial fistula (ABF) is a rare and potentially lethal complication of thoracic aortic replacement surgery. Currently, thoracic endovascular aortic repair (TEVAR) has emerged as a less invasive alternative to open surgery for ABF to facilitate prompt hemostasis. However, there are no publishe...

Descripción completa

Detalles Bibliográficos
Autores principales: Takahashi, Kyosuke, Kajitani, Misa, Kamada, Takaaki, Takayama, Wataru, Kobayashi, Yoshiro
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Berlin Heidelberg 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5804618/
https://www.ncbi.nlm.nih.gov/pubmed/29457078
http://dx.doi.org/10.1186/s40981-017-0103-8
Descripción
Sumario:Aortobronchial fistula (ABF) is a rare and potentially lethal complication of thoracic aortic replacement surgery. Currently, thoracic endovascular aortic repair (TEVAR) has emerged as a less invasive alternative to open surgery for ABF to facilitate prompt hemostasis. However, there are no published reports of TEVAR for ABF, particularly for presentation with life-threatening respiratory failure from massive hemoptysis. A 48-year-old male patient, who had recently undergone aortic root and arch replacement due to aortic dissection, was transferred to the emergency department with massive hemoptysis and severe dyspnea. A single-lumen endotracheal tube was immediately placed in the right main bronchus to protect the nonbleeding lung from spillage of blood. Chest computed tomography (CT) showed leakage of contrast material from the distal anastomosis of the aortic graft and consolidated lung tissue adjacent to the leakage. He was diagnosed with an ABF following aortic arch replacement, and an emergency TEVAR was performed. After adequate hemostasis, severe hypercapnia remained uncorrected despite the maximum ventilatory support. Thus, venovenous extracorporeal membrane oxygenation (VV ECMO) was immediately initiated, and severe respiratory acidosis improved dramatically. Furthermore, VV ECMO facilitated prompt bronchoscopic washout of the remaining blood clot without any danger of respiratory collapse and was weaned off successfully after 5 days as ventilation improved. This case demonstrates that emergency TEVAR in combination with VV ECMO can be a rescue strategy for massive hemoptysis from an ABF.