Comparison of inflationary non-invasive blood pressure (iNIBP) monitoring technology and conventional deflationary non-invasive blood pressure (dNIBP) measurement in detecting hypotension during cesarean section

BACKGROUND: The Nihon Kohden linear inflationary non-invasive blood pressure (iNIBP) monitoring technology is an oscillometric device that measures blood pressure by detecting oscillations during inflation. Systolic blood pressure can be recorded without overinflating the cuff higher than the true s...

Descripción completa

Detalles Bibliográficos
Autores principales: Yamashita, Akiko, Irikoma, Shingo
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Berlin Heidelberg 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5804667/
https://www.ncbi.nlm.nih.gov/pubmed/29457115
http://dx.doi.org/10.1186/s40981-017-0145-y
_version_ 1783298885881430016
author Yamashita, Akiko
Irikoma, Shingo
author_facet Yamashita, Akiko
Irikoma, Shingo
author_sort Yamashita, Akiko
collection PubMed
description BACKGROUND: The Nihon Kohden linear inflationary non-invasive blood pressure (iNIBP) monitoring technology is an oscillometric device that measures blood pressure by detecting oscillations during inflation. Systolic blood pressure can be recorded without overinflating the cuff higher than the true systolic pressure. Thus, total time taken for inflation and deflation is shorter than that by the conventional deflation devices. In this study, the ability of iNIBP to detect maternal hypotension during cesarean section faster than deflationary non-invasive blood pressure (dNIBP) monitoring devices under clinical settings was evaluated prospectively. METHODS: A prospective study of singleton planned cesarean sections at a tertiary center was conducted from August 2015 to April 2016. The combined spinal-epidural anesthesia (CSEA) technique through a single puncture was performed for cesarean section at the center where the study was carried out. An iNIBP cuff was placed on the same arm as the intravenous line, and a dNIBP cuff was placed on the other arm. Due to left uterine displacement by approximately 10° tilt of OR table, hypotension in this study was defined as systolic pressure of 107 mmHg or less, when measured in the left arm, which was about 10 cm lower, and pressure of 92 mmHg or less in the right arm which was about 10 cm higher. This setup was done to evaluate which device detected hypotension faster under clinical settings. A two-tailed Z test was performed to statistically analyze the difference between iNIBP and dNIBP measurement results. RESULTS: One hundred singleton planned cesarean deliveries under CSEA were included after 36 weeks of gestation. Out of the 100, 76 women (76%) experienced maternal hypotension. Of these, iNIBP detected hypotension faster than dNIBP in 47 cases (61.8%). CONCLUSION: It was found that iNIBP detected hypotension faster than conventional dNIBP without compromising the reliability of measurement. This may lead to early treatment of maternal hypotension and prevention of adverse events related to the mother and the fetus.
format Online
Article
Text
id pubmed-5804667
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Springer Berlin Heidelberg
record_format MEDLINE/PubMed
spelling pubmed-58046672018-02-14 Comparison of inflationary non-invasive blood pressure (iNIBP) monitoring technology and conventional deflationary non-invasive blood pressure (dNIBP) measurement in detecting hypotension during cesarean section Yamashita, Akiko Irikoma, Shingo JA Clin Rep Clinical Research Letter BACKGROUND: The Nihon Kohden linear inflationary non-invasive blood pressure (iNIBP) monitoring technology is an oscillometric device that measures blood pressure by detecting oscillations during inflation. Systolic blood pressure can be recorded without overinflating the cuff higher than the true systolic pressure. Thus, total time taken for inflation and deflation is shorter than that by the conventional deflation devices. In this study, the ability of iNIBP to detect maternal hypotension during cesarean section faster than deflationary non-invasive blood pressure (dNIBP) monitoring devices under clinical settings was evaluated prospectively. METHODS: A prospective study of singleton planned cesarean sections at a tertiary center was conducted from August 2015 to April 2016. The combined spinal-epidural anesthesia (CSEA) technique through a single puncture was performed for cesarean section at the center where the study was carried out. An iNIBP cuff was placed on the same arm as the intravenous line, and a dNIBP cuff was placed on the other arm. Due to left uterine displacement by approximately 10° tilt of OR table, hypotension in this study was defined as systolic pressure of 107 mmHg or less, when measured in the left arm, which was about 10 cm lower, and pressure of 92 mmHg or less in the right arm which was about 10 cm higher. This setup was done to evaluate which device detected hypotension faster under clinical settings. A two-tailed Z test was performed to statistically analyze the difference between iNIBP and dNIBP measurement results. RESULTS: One hundred singleton planned cesarean deliveries under CSEA were included after 36 weeks of gestation. Out of the 100, 76 women (76%) experienced maternal hypotension. Of these, iNIBP detected hypotension faster than dNIBP in 47 cases (61.8%). CONCLUSION: It was found that iNIBP detected hypotension faster than conventional dNIBP without compromising the reliability of measurement. This may lead to early treatment of maternal hypotension and prevention of adverse events related to the mother and the fetus. Springer Berlin Heidelberg 2018-01-05 /pmc/articles/PMC5804667/ /pubmed/29457115 http://dx.doi.org/10.1186/s40981-017-0145-y Text en © The Author(s) 2018 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.
spellingShingle Clinical Research Letter
Yamashita, Akiko
Irikoma, Shingo
Comparison of inflationary non-invasive blood pressure (iNIBP) monitoring technology and conventional deflationary non-invasive blood pressure (dNIBP) measurement in detecting hypotension during cesarean section
title Comparison of inflationary non-invasive blood pressure (iNIBP) monitoring technology and conventional deflationary non-invasive blood pressure (dNIBP) measurement in detecting hypotension during cesarean section
title_full Comparison of inflationary non-invasive blood pressure (iNIBP) monitoring technology and conventional deflationary non-invasive blood pressure (dNIBP) measurement in detecting hypotension during cesarean section
title_fullStr Comparison of inflationary non-invasive blood pressure (iNIBP) monitoring technology and conventional deflationary non-invasive blood pressure (dNIBP) measurement in detecting hypotension during cesarean section
title_full_unstemmed Comparison of inflationary non-invasive blood pressure (iNIBP) monitoring technology and conventional deflationary non-invasive blood pressure (dNIBP) measurement in detecting hypotension during cesarean section
title_short Comparison of inflationary non-invasive blood pressure (iNIBP) monitoring technology and conventional deflationary non-invasive blood pressure (dNIBP) measurement in detecting hypotension during cesarean section
title_sort comparison of inflationary non-invasive blood pressure (inibp) monitoring technology and conventional deflationary non-invasive blood pressure (dnibp) measurement in detecting hypotension during cesarean section
topic Clinical Research Letter
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5804667/
https://www.ncbi.nlm.nih.gov/pubmed/29457115
http://dx.doi.org/10.1186/s40981-017-0145-y
work_keys_str_mv AT yamashitaakiko comparisonofinflationarynoninvasivebloodpressureinibpmonitoringtechnologyandconventionaldeflationarynoninvasivebloodpressurednibpmeasurementindetectinghypotensionduringcesareansection
AT irikomashingo comparisonofinflationarynoninvasivebloodpressureinibpmonitoringtechnologyandconventionaldeflationarynoninvasivebloodpressurednibpmeasurementindetectinghypotensionduringcesareansection