Cargando…
Blood Metal Ion Thresholds to Identify Patients with Metal-on-Metal Hip Implants at Risk of Adverse Reactions to Metal Debris: An External Multicenter Validation Study of Birmingham Hip Resurfacing and Corail-Pinnacle Implants
BACKGROUND: The authors of recent studies have reported newly devised implant-specific blood metal ion thresholds to predict adverse reactions to metal debris (ARMD) in patients who have undergone unilateral or bilateral metal-on-metal (MoM) hip arthroplasty. These thresholds were most effective for...
Autores principales: | Matharu, Gulraj S., Berryman, Fiona, Judge, Andrew, Reito, Aleksi, McConnell, Jamie, Lainiala, Olli, Young, Stephen, Eskelinen, Antti, Pandit, Hemant G., Murray, David W. |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
The Journal of Bone and Joint Surgery, Inc.
2017
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5805279/ https://www.ncbi.nlm.nih.gov/pubmed/28926382 http://dx.doi.org/10.2106/JBJS.16.01568 |
Ejemplares similares
-
Complications and re-revisions after revisions of 528 metal-on-metal hips because of adverse reaction to metal debris
por: Lainiala, Olli, et al.
Publicado: (2020) -
Revision surgery of metal-on-metal hip arthroplasties for adverse reactions to metal debris: A clinical update
por: Matharu, Gulraj S, et al.
Publicado: (2018) -
Prevalence of Failure due to Adverse Reaction to Metal Debris in Modern, Medium and Large Diameter Metal-on-Metal Hip Replacements – The Effect of Novel Screening Methods: Systematic Review and Metaregression Analysis
por: Reito, Aleksi, et al.
Publicado: (2016) -
Adverse reaction to metal debris after Birmingham hip resurfacing arthroplasty
por: Junnila, Mika, et al.
Publicado: (2015) -
Implant failure in bilateral metal-on-metal hip resurfacing arthroplasties: a clinical and pathological study
por: Uchihara, Yoshinubo, et al.
Publicado: (2018)