Cargando…

Clinical Translation of Tethered Confocal Microscopy Capsule for Unsedated Diagnosis of Eosinophilic Esophagitis

Esophagogastroduodenoscopy (EGD) is a widely used procedure, posing significant financial burden on both healthcare systems and patients. Moreover, EGD is time consuming, sometimes difficult to tolerate, and suffers from an imperfect diagnostic yield as the limited number of collected biopsies does...

Descripción completa

Detalles Bibliográficos
Autores principales: Tabatabaei, Nima, Kang, DongKyun, Kim, Minkyu, Wu, Tao, Grant, Catriona N., Rosenberg, Mireille, Nishioka, Norman S., Hesterberg, Paul E., Garber, John, Yuan, Qian, Katz, Aubrey J., Tearney, Guillermo J.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Nature Publishing Group UK 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5805683/
https://www.ncbi.nlm.nih.gov/pubmed/29422678
http://dx.doi.org/10.1038/s41598-018-20668-8
_version_ 1783299002423312384
author Tabatabaei, Nima
Kang, DongKyun
Kim, Minkyu
Wu, Tao
Grant, Catriona N.
Rosenberg, Mireille
Nishioka, Norman S.
Hesterberg, Paul E.
Garber, John
Yuan, Qian
Katz, Aubrey J.
Tearney, Guillermo J.
author_facet Tabatabaei, Nima
Kang, DongKyun
Kim, Minkyu
Wu, Tao
Grant, Catriona N.
Rosenberg, Mireille
Nishioka, Norman S.
Hesterberg, Paul E.
Garber, John
Yuan, Qian
Katz, Aubrey J.
Tearney, Guillermo J.
author_sort Tabatabaei, Nima
collection PubMed
description Esophagogastroduodenoscopy (EGD) is a widely used procedure, posing significant financial burden on both healthcare systems and patients. Moreover, EGD is time consuming, sometimes difficult to tolerate, and suffers from an imperfect diagnostic yield as the limited number of collected biopsies does not represent the whole organ. In this paper, we report on technological and clinical feasibility of a swallowable tethered endomicroscopy capsule, which is administered without sedation, to image large regions of esophageal and gastric mucosa at the cellular level. To demonstrate imaging capabilities, we conducted a human pilot study (n = 17) on Eosinophilic Esophagitis (EoE) patients and healthy volunteers from which representative cases are presented and discussed. Results indicate that, compared to endoscopic biopsy, unsedated tethered capsule endomicroscopy obtains orders of magnitude more cellular information while successfully resolving characteristic tissue microscopic features such as stratified squamous epithelium, lamina propria papillae, intraepithelial eosinophils, and gastric cardia and body/fundic mucosa epithelia. Based on the major import of whole organ, cellular-level microscopy to obviate sampling error and the clear cost and convenience advantages of unsedated procedure, we believe that this tool has the potential to become a simpler and more effective device for diagnosing and monitoring the therapeutic response of EoE and other esophageal diseases.
format Online
Article
Text
id pubmed-5805683
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Nature Publishing Group UK
record_format MEDLINE/PubMed
spelling pubmed-58056832018-02-16 Clinical Translation of Tethered Confocal Microscopy Capsule for Unsedated Diagnosis of Eosinophilic Esophagitis Tabatabaei, Nima Kang, DongKyun Kim, Minkyu Wu, Tao Grant, Catriona N. Rosenberg, Mireille Nishioka, Norman S. Hesterberg, Paul E. Garber, John Yuan, Qian Katz, Aubrey J. Tearney, Guillermo J. Sci Rep Article Esophagogastroduodenoscopy (EGD) is a widely used procedure, posing significant financial burden on both healthcare systems and patients. Moreover, EGD is time consuming, sometimes difficult to tolerate, and suffers from an imperfect diagnostic yield as the limited number of collected biopsies does not represent the whole organ. In this paper, we report on technological and clinical feasibility of a swallowable tethered endomicroscopy capsule, which is administered without sedation, to image large regions of esophageal and gastric mucosa at the cellular level. To demonstrate imaging capabilities, we conducted a human pilot study (n = 17) on Eosinophilic Esophagitis (EoE) patients and healthy volunteers from which representative cases are presented and discussed. Results indicate that, compared to endoscopic biopsy, unsedated tethered capsule endomicroscopy obtains orders of magnitude more cellular information while successfully resolving characteristic tissue microscopic features such as stratified squamous epithelium, lamina propria papillae, intraepithelial eosinophils, and gastric cardia and body/fundic mucosa epithelia. Based on the major import of whole organ, cellular-level microscopy to obviate sampling error and the clear cost and convenience advantages of unsedated procedure, we believe that this tool has the potential to become a simpler and more effective device for diagnosing and monitoring the therapeutic response of EoE and other esophageal diseases. Nature Publishing Group UK 2018-02-08 /pmc/articles/PMC5805683/ /pubmed/29422678 http://dx.doi.org/10.1038/s41598-018-20668-8 Text en © The Author(s) 2018 Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons license and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/.
spellingShingle Article
Tabatabaei, Nima
Kang, DongKyun
Kim, Minkyu
Wu, Tao
Grant, Catriona N.
Rosenberg, Mireille
Nishioka, Norman S.
Hesterberg, Paul E.
Garber, John
Yuan, Qian
Katz, Aubrey J.
Tearney, Guillermo J.
Clinical Translation of Tethered Confocal Microscopy Capsule for Unsedated Diagnosis of Eosinophilic Esophagitis
title Clinical Translation of Tethered Confocal Microscopy Capsule for Unsedated Diagnosis of Eosinophilic Esophagitis
title_full Clinical Translation of Tethered Confocal Microscopy Capsule for Unsedated Diagnosis of Eosinophilic Esophagitis
title_fullStr Clinical Translation of Tethered Confocal Microscopy Capsule for Unsedated Diagnosis of Eosinophilic Esophagitis
title_full_unstemmed Clinical Translation of Tethered Confocal Microscopy Capsule for Unsedated Diagnosis of Eosinophilic Esophagitis
title_short Clinical Translation of Tethered Confocal Microscopy Capsule for Unsedated Diagnosis of Eosinophilic Esophagitis
title_sort clinical translation of tethered confocal microscopy capsule for unsedated diagnosis of eosinophilic esophagitis
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5805683/
https://www.ncbi.nlm.nih.gov/pubmed/29422678
http://dx.doi.org/10.1038/s41598-018-20668-8
work_keys_str_mv AT tabatabaeinima clinicaltranslationoftetheredconfocalmicroscopycapsuleforunsedateddiagnosisofeosinophilicesophagitis
AT kangdongkyun clinicaltranslationoftetheredconfocalmicroscopycapsuleforunsedateddiagnosisofeosinophilicesophagitis
AT kimminkyu clinicaltranslationoftetheredconfocalmicroscopycapsuleforunsedateddiagnosisofeosinophilicesophagitis
AT wutao clinicaltranslationoftetheredconfocalmicroscopycapsuleforunsedateddiagnosisofeosinophilicesophagitis
AT grantcatrionan clinicaltranslationoftetheredconfocalmicroscopycapsuleforunsedateddiagnosisofeosinophilicesophagitis
AT rosenbergmireille clinicaltranslationoftetheredconfocalmicroscopycapsuleforunsedateddiagnosisofeosinophilicesophagitis
AT nishiokanormans clinicaltranslationoftetheredconfocalmicroscopycapsuleforunsedateddiagnosisofeosinophilicesophagitis
AT hesterbergpaule clinicaltranslationoftetheredconfocalmicroscopycapsuleforunsedateddiagnosisofeosinophilicesophagitis
AT garberjohn clinicaltranslationoftetheredconfocalmicroscopycapsuleforunsedateddiagnosisofeosinophilicesophagitis
AT yuanqian clinicaltranslationoftetheredconfocalmicroscopycapsuleforunsedateddiagnosisofeosinophilicesophagitis
AT katzaubreyj clinicaltranslationoftetheredconfocalmicroscopycapsuleforunsedateddiagnosisofeosinophilicesophagitis
AT tearneyguillermoj clinicaltranslationoftetheredconfocalmicroscopycapsuleforunsedateddiagnosisofeosinophilicesophagitis