Cargando…
Dose and slice thickness evaluation with nMAG gel dosimeters in computed tomography
Computed tomography (CT) has been widely used in clinical diagnosis. It is important to estimate radiation dose and perform image quality assurance procedures for CT scans. In this study, nMAG gel dosimeters were used to simultaneously measure the 300-mm weighted CT dose index (CTDI) and slice sensi...
Autores principales: | , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Nature Publishing Group UK
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5805745/ https://www.ncbi.nlm.nih.gov/pubmed/29422538 http://dx.doi.org/10.1038/s41598-018-21022-8 |
_version_ | 1783299017461989376 |
---|---|
author | Chuang, Chun-Chao Wu, Jay |
author_facet | Chuang, Chun-Chao Wu, Jay |
author_sort | Chuang, Chun-Chao |
collection | PubMed |
description | Computed tomography (CT) has been widely used in clinical diagnosis. It is important to estimate radiation dose and perform image quality assurance procedures for CT scans. In this study, nMAG gel dosimeters were used to simultaneously measure the 300-mm weighted CT dose index (CTDI) and slice sensitivity profile (SSP) for multiple detector CT (MDCT). Magnetic resonance imaging (MRI) was performed on the irradiated gel to create R(2)‒dose response curves for the tube voltages of 120 and 140 kVp. The gel dosimeters were loaded in three home-made cylindrical phantoms to obtain CTDI(100) and CTDI(300). The full width at half maximum (FWHM) for 2, 5, 10, 14.4, and 38.4-mm slice thicknesses was measured and compared with the result obtained by radiochromic films. The difference in weighted CTDI(100) obtained by the gel dosimeter and ionization chamber was less than 1%. The CTDI efficiency at 120 and 140 kVp was in the range of 80.1%–82.5%. The FWHM of SSP measured by the gel dosimeter matched very well with the nominal slice thickness. The use of nMAG gel dosimeters combined with the home-made cylindrical phantoms can provide 300-mm weighted CTDI and slice thickness information, showing potential for quality assurance and clinical applications in MDCT. |
format | Online Article Text |
id | pubmed-5805745 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | Nature Publishing Group UK |
record_format | MEDLINE/PubMed |
spelling | pubmed-58057452018-02-16 Dose and slice thickness evaluation with nMAG gel dosimeters in computed tomography Chuang, Chun-Chao Wu, Jay Sci Rep Article Computed tomography (CT) has been widely used in clinical diagnosis. It is important to estimate radiation dose and perform image quality assurance procedures for CT scans. In this study, nMAG gel dosimeters were used to simultaneously measure the 300-mm weighted CT dose index (CTDI) and slice sensitivity profile (SSP) for multiple detector CT (MDCT). Magnetic resonance imaging (MRI) was performed on the irradiated gel to create R(2)‒dose response curves for the tube voltages of 120 and 140 kVp. The gel dosimeters were loaded in three home-made cylindrical phantoms to obtain CTDI(100) and CTDI(300). The full width at half maximum (FWHM) for 2, 5, 10, 14.4, and 38.4-mm slice thicknesses was measured and compared with the result obtained by radiochromic films. The difference in weighted CTDI(100) obtained by the gel dosimeter and ionization chamber was less than 1%. The CTDI efficiency at 120 and 140 kVp was in the range of 80.1%–82.5%. The FWHM of SSP measured by the gel dosimeter matched very well with the nominal slice thickness. The use of nMAG gel dosimeters combined with the home-made cylindrical phantoms can provide 300-mm weighted CTDI and slice thickness information, showing potential for quality assurance and clinical applications in MDCT. Nature Publishing Group UK 2018-02-08 /pmc/articles/PMC5805745/ /pubmed/29422538 http://dx.doi.org/10.1038/s41598-018-21022-8 Text en © The Author(s) 2018 Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons license and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/. |
spellingShingle | Article Chuang, Chun-Chao Wu, Jay Dose and slice thickness evaluation with nMAG gel dosimeters in computed tomography |
title | Dose and slice thickness evaluation with nMAG gel dosimeters in computed tomography |
title_full | Dose and slice thickness evaluation with nMAG gel dosimeters in computed tomography |
title_fullStr | Dose and slice thickness evaluation with nMAG gel dosimeters in computed tomography |
title_full_unstemmed | Dose and slice thickness evaluation with nMAG gel dosimeters in computed tomography |
title_short | Dose and slice thickness evaluation with nMAG gel dosimeters in computed tomography |
title_sort | dose and slice thickness evaluation with nmag gel dosimeters in computed tomography |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5805745/ https://www.ncbi.nlm.nih.gov/pubmed/29422538 http://dx.doi.org/10.1038/s41598-018-21022-8 |
work_keys_str_mv | AT chuangchunchao doseandslicethicknessevaluationwithnmaggeldosimetersincomputedtomography AT wujay doseandslicethicknessevaluationwithnmaggeldosimetersincomputedtomography |