Cargando…

Dose and slice thickness evaluation with nMAG gel dosimeters in computed tomography

Computed tomography (CT) has been widely used in clinical diagnosis. It is important to estimate radiation dose and perform image quality assurance procedures for CT scans. In this study, nMAG gel dosimeters were used to simultaneously measure the 300-mm weighted CT dose index (CTDI) and slice sensi...

Descripción completa

Detalles Bibliográficos
Autores principales: Chuang, Chun-Chao, Wu, Jay
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Nature Publishing Group UK 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5805745/
https://www.ncbi.nlm.nih.gov/pubmed/29422538
http://dx.doi.org/10.1038/s41598-018-21022-8
_version_ 1783299017461989376
author Chuang, Chun-Chao
Wu, Jay
author_facet Chuang, Chun-Chao
Wu, Jay
author_sort Chuang, Chun-Chao
collection PubMed
description Computed tomography (CT) has been widely used in clinical diagnosis. It is important to estimate radiation dose and perform image quality assurance procedures for CT scans. In this study, nMAG gel dosimeters were used to simultaneously measure the 300-mm weighted CT dose index (CTDI) and slice sensitivity profile (SSP) for multiple detector CT (MDCT). Magnetic resonance imaging (MRI) was performed on the irradiated gel to create R(2)‒dose response curves for the tube voltages of 120 and 140 kVp. The gel dosimeters were loaded in three home-made cylindrical phantoms to obtain CTDI(100) and CTDI(300). The full width at half maximum (FWHM) for 2, 5, 10, 14.4, and 38.4-mm slice thicknesses was measured and compared with the result obtained by radiochromic films. The difference in weighted CTDI(100) obtained by the gel dosimeter and ionization chamber was less than 1%. The CTDI efficiency at 120 and 140 kVp was in the range of 80.1%–82.5%. The FWHM of SSP measured by the gel dosimeter matched very well with the nominal slice thickness. The use of nMAG gel dosimeters combined with the home-made cylindrical phantoms can provide 300-mm weighted CTDI and slice thickness information, showing potential for quality assurance and clinical applications in MDCT.
format Online
Article
Text
id pubmed-5805745
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Nature Publishing Group UK
record_format MEDLINE/PubMed
spelling pubmed-58057452018-02-16 Dose and slice thickness evaluation with nMAG gel dosimeters in computed tomography Chuang, Chun-Chao Wu, Jay Sci Rep Article Computed tomography (CT) has been widely used in clinical diagnosis. It is important to estimate radiation dose and perform image quality assurance procedures for CT scans. In this study, nMAG gel dosimeters were used to simultaneously measure the 300-mm weighted CT dose index (CTDI) and slice sensitivity profile (SSP) for multiple detector CT (MDCT). Magnetic resonance imaging (MRI) was performed on the irradiated gel to create R(2)‒dose response curves for the tube voltages of 120 and 140 kVp. The gel dosimeters were loaded in three home-made cylindrical phantoms to obtain CTDI(100) and CTDI(300). The full width at half maximum (FWHM) for 2, 5, 10, 14.4, and 38.4-mm slice thicknesses was measured and compared with the result obtained by radiochromic films. The difference in weighted CTDI(100) obtained by the gel dosimeter and ionization chamber was less than 1%. The CTDI efficiency at 120 and 140 kVp was in the range of 80.1%–82.5%. The FWHM of SSP measured by the gel dosimeter matched very well with the nominal slice thickness. The use of nMAG gel dosimeters combined with the home-made cylindrical phantoms can provide 300-mm weighted CTDI and slice thickness information, showing potential for quality assurance and clinical applications in MDCT. Nature Publishing Group UK 2018-02-08 /pmc/articles/PMC5805745/ /pubmed/29422538 http://dx.doi.org/10.1038/s41598-018-21022-8 Text en © The Author(s) 2018 Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons license and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/.
spellingShingle Article
Chuang, Chun-Chao
Wu, Jay
Dose and slice thickness evaluation with nMAG gel dosimeters in computed tomography
title Dose and slice thickness evaluation with nMAG gel dosimeters in computed tomography
title_full Dose and slice thickness evaluation with nMAG gel dosimeters in computed tomography
title_fullStr Dose and slice thickness evaluation with nMAG gel dosimeters in computed tomography
title_full_unstemmed Dose and slice thickness evaluation with nMAG gel dosimeters in computed tomography
title_short Dose and slice thickness evaluation with nMAG gel dosimeters in computed tomography
title_sort dose and slice thickness evaluation with nmag gel dosimeters in computed tomography
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5805745/
https://www.ncbi.nlm.nih.gov/pubmed/29422538
http://dx.doi.org/10.1038/s41598-018-21022-8
work_keys_str_mv AT chuangchunchao doseandslicethicknessevaluationwithnmaggeldosimetersincomputedtomography
AT wujay doseandslicethicknessevaluationwithnmaggeldosimetersincomputedtomography