Cargando…

Validation of the ADAMO Care Watch for step counting in older adults

BACKGROUND: Accurate measurement devices are required to objectively quantify physical activity. Wearable activity monitors, such as pedometers, may serve as affordable and feasible instruments for measuring physical activity levels in older adults during their normal activities of daily living. Cur...

Descripción completa

Detalles Bibliográficos
Autores principales: Magistro, Daniele, Brustio, Paolo Riccardo, Ivaldi, Marco, Esliger, Dale Winfield, Zecca, Massimiliano, Rainoldi, Alberto, Boccia, Gennaro
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5806873/
https://www.ncbi.nlm.nih.gov/pubmed/29425196
http://dx.doi.org/10.1371/journal.pone.0190753
_version_ 1783299185690279936
author Magistro, Daniele
Brustio, Paolo Riccardo
Ivaldi, Marco
Esliger, Dale Winfield
Zecca, Massimiliano
Rainoldi, Alberto
Boccia, Gennaro
author_facet Magistro, Daniele
Brustio, Paolo Riccardo
Ivaldi, Marco
Esliger, Dale Winfield
Zecca, Massimiliano
Rainoldi, Alberto
Boccia, Gennaro
author_sort Magistro, Daniele
collection PubMed
description BACKGROUND: Accurate measurement devices are required to objectively quantify physical activity. Wearable activity monitors, such as pedometers, may serve as affordable and feasible instruments for measuring physical activity levels in older adults during their normal activities of daily living. Currently few available accelerometer-based steps counting devices have been shown to be accurate at slow walking speeds, therefore there is still lacking appropriate devices tailored for slow speed ambulation, typical of older adults. This study aimed to assess the validity of step counting using the pedometer function of the ADAMO Care Watch, containing an embedded algorithm for measuring physical activity in older adults. METHODS: Twenty older adults aged ≥ 65 years (mean ± SD, 75±7 years; range, 68–91) and 20 young adults (25±5 years, range 20–40), wore a care watch on each wrist and performed a number of randomly ordered tasks: walking at slow, normal and fast self-paced speeds; a Timed Up and Go test (TUG); a step test and ascending/descending stairs. The criterion measure was the actual number of steps observed, counted with a manual tally counter. Absolute percentage error scores, Intraclass Correlation Coefficients (ICC), and Bland–Altman plots were used to assess validity. RESULTS: ADAMO Care Watch demonstrated high validity during slow and normal speeds (range 0.5–1.5 m/s) showing an absolute error from 1.3% to 1.9% in the older adult group and from 0.7% to 2.7% in the young adult group. The percentage error for the 30-metre walking tasks increased with faster pace in both young adult (17%) and older adult groups (6%). In the TUG test, there was less error in the steps recorded for older adults (1.3% to 2.2%) than the young adults (6.6% to 7.2%). For the total sample, the ICCs for the ADAMO Care Watch for the 30-metre walking tasks at each speed and for the TUG test were ranged between 0.931 to 0.985. CONCLUSION: These findings provide evidence that the ADAMO Care Watch demonstrated highly accurate measurements of the steps count in all activities, particularly walking at normal and slow speeds. Therefore, these data support the inclusion of the ADAMO Care Watch in clinical applications for measuring the number of steps taken by older adults at normal, slow walking speeds.
format Online
Article
Text
id pubmed-5806873
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-58068732018-02-23 Validation of the ADAMO Care Watch for step counting in older adults Magistro, Daniele Brustio, Paolo Riccardo Ivaldi, Marco Esliger, Dale Winfield Zecca, Massimiliano Rainoldi, Alberto Boccia, Gennaro PLoS One Research Article BACKGROUND: Accurate measurement devices are required to objectively quantify physical activity. Wearable activity monitors, such as pedometers, may serve as affordable and feasible instruments for measuring physical activity levels in older adults during their normal activities of daily living. Currently few available accelerometer-based steps counting devices have been shown to be accurate at slow walking speeds, therefore there is still lacking appropriate devices tailored for slow speed ambulation, typical of older adults. This study aimed to assess the validity of step counting using the pedometer function of the ADAMO Care Watch, containing an embedded algorithm for measuring physical activity in older adults. METHODS: Twenty older adults aged ≥ 65 years (mean ± SD, 75±7 years; range, 68–91) and 20 young adults (25±5 years, range 20–40), wore a care watch on each wrist and performed a number of randomly ordered tasks: walking at slow, normal and fast self-paced speeds; a Timed Up and Go test (TUG); a step test and ascending/descending stairs. The criterion measure was the actual number of steps observed, counted with a manual tally counter. Absolute percentage error scores, Intraclass Correlation Coefficients (ICC), and Bland–Altman plots were used to assess validity. RESULTS: ADAMO Care Watch demonstrated high validity during slow and normal speeds (range 0.5–1.5 m/s) showing an absolute error from 1.3% to 1.9% in the older adult group and from 0.7% to 2.7% in the young adult group. The percentage error for the 30-metre walking tasks increased with faster pace in both young adult (17%) and older adult groups (6%). In the TUG test, there was less error in the steps recorded for older adults (1.3% to 2.2%) than the young adults (6.6% to 7.2%). For the total sample, the ICCs for the ADAMO Care Watch for the 30-metre walking tasks at each speed and for the TUG test were ranged between 0.931 to 0.985. CONCLUSION: These findings provide evidence that the ADAMO Care Watch demonstrated highly accurate measurements of the steps count in all activities, particularly walking at normal and slow speeds. Therefore, these data support the inclusion of the ADAMO Care Watch in clinical applications for measuring the number of steps taken by older adults at normal, slow walking speeds. Public Library of Science 2018-02-09 /pmc/articles/PMC5806873/ /pubmed/29425196 http://dx.doi.org/10.1371/journal.pone.0190753 Text en © 2018 Magistro et al http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Research Article
Magistro, Daniele
Brustio, Paolo Riccardo
Ivaldi, Marco
Esliger, Dale Winfield
Zecca, Massimiliano
Rainoldi, Alberto
Boccia, Gennaro
Validation of the ADAMO Care Watch for step counting in older adults
title Validation of the ADAMO Care Watch for step counting in older adults
title_full Validation of the ADAMO Care Watch for step counting in older adults
title_fullStr Validation of the ADAMO Care Watch for step counting in older adults
title_full_unstemmed Validation of the ADAMO Care Watch for step counting in older adults
title_short Validation of the ADAMO Care Watch for step counting in older adults
title_sort validation of the adamo care watch for step counting in older adults
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5806873/
https://www.ncbi.nlm.nih.gov/pubmed/29425196
http://dx.doi.org/10.1371/journal.pone.0190753
work_keys_str_mv AT magistrodaniele validationoftheadamocarewatchforstepcountinginolderadults
AT brustiopaoloriccardo validationoftheadamocarewatchforstepcountinginolderadults
AT ivaldimarco validationoftheadamocarewatchforstepcountinginolderadults
AT esligerdalewinfield validationoftheadamocarewatchforstepcountinginolderadults
AT zeccamassimiliano validationoftheadamocarewatchforstepcountinginolderadults
AT rainoldialberto validationoftheadamocarewatchforstepcountinginolderadults
AT bocciagennaro validationoftheadamocarewatchforstepcountinginolderadults