Cargando…
A novel automatic flow method with direct-injection photometric detector for determination of dissolved reactive phosphorus in wastewater and freshwater samples
The novel automatic flow system, direct-injection detector (DID) integrated with multi-pumping flow system (MPFS), dedicated for the photometric determination of orthophosphates in wastewater and freshwater samples is for the first time described. All reagents and the sample were injected simultaneo...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer International Publishing
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5809572/ https://www.ncbi.nlm.nih.gov/pubmed/29435674 http://dx.doi.org/10.1007/s10661-018-6511-z |
_version_ | 1783299589683544064 |
---|---|
author | Koronkiewicz, Stanislawa Trifescu, Mihaela Smoczynski, Lech Ratnaweera, Harsha Kalinowski, Slawomir |
author_facet | Koronkiewicz, Stanislawa Trifescu, Mihaela Smoczynski, Lech Ratnaweera, Harsha Kalinowski, Slawomir |
author_sort | Koronkiewicz, Stanislawa |
collection | PubMed |
description | The novel automatic flow system, direct-injection detector (DID) integrated with multi-pumping flow system (MPFS), dedicated for the photometric determination of orthophosphates in wastewater and freshwater samples is for the first time described. All reagents and the sample were injected simultaneously, in counter-current into the reaction-detection chamber by the system of specially selected for this purpose solenoid micro-pumps. The micro-pumps provided good precision and accuracy of the injected volumes. For the determination of orthophosphates, the molybdenum blue method was employed. The developed method can be used to detect orthophosphate in the range 0.1–12 mg L(−1), with the repeatability (RSD) about 2.2% at 4 mg L(−1) and a very high injection throughput of 120 injections h(−1). It was possible to achieve a very small consumption of reagents (10 μL of ammonium molybdate and 10 μL of ascorbic acid) and sample (20 μL). The volume of generated waste was only 440 μL per analysis. The method has been successfully applied, giving a good accuracy, to determination of orthophosphates in complex matrix samples: treated wastewater, lake water and reference sample of groundwater. The developed system is compact, small in both size and weight, requires 12 V in supply voltage, which are desirable for truly portable equipment used in routine analysis. The simplicity of the system should result in its greater long-time reliability comparing to other flow methods previously described. |
format | Online Article Text |
id | pubmed-5809572 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | Springer International Publishing |
record_format | MEDLINE/PubMed |
spelling | pubmed-58095722018-02-22 A novel automatic flow method with direct-injection photometric detector for determination of dissolved reactive phosphorus in wastewater and freshwater samples Koronkiewicz, Stanislawa Trifescu, Mihaela Smoczynski, Lech Ratnaweera, Harsha Kalinowski, Slawomir Environ Monit Assess Article The novel automatic flow system, direct-injection detector (DID) integrated with multi-pumping flow system (MPFS), dedicated for the photometric determination of orthophosphates in wastewater and freshwater samples is for the first time described. All reagents and the sample were injected simultaneously, in counter-current into the reaction-detection chamber by the system of specially selected for this purpose solenoid micro-pumps. The micro-pumps provided good precision and accuracy of the injected volumes. For the determination of orthophosphates, the molybdenum blue method was employed. The developed method can be used to detect orthophosphate in the range 0.1–12 mg L(−1), with the repeatability (RSD) about 2.2% at 4 mg L(−1) and a very high injection throughput of 120 injections h(−1). It was possible to achieve a very small consumption of reagents (10 μL of ammonium molybdate and 10 μL of ascorbic acid) and sample (20 μL). The volume of generated waste was only 440 μL per analysis. The method has been successfully applied, giving a good accuracy, to determination of orthophosphates in complex matrix samples: treated wastewater, lake water and reference sample of groundwater. The developed system is compact, small in both size and weight, requires 12 V in supply voltage, which are desirable for truly portable equipment used in routine analysis. The simplicity of the system should result in its greater long-time reliability comparing to other flow methods previously described. Springer International Publishing 2018-02-12 2018 /pmc/articles/PMC5809572/ /pubmed/29435674 http://dx.doi.org/10.1007/s10661-018-6511-z Text en © The Author(s) 2018 Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. |
spellingShingle | Article Koronkiewicz, Stanislawa Trifescu, Mihaela Smoczynski, Lech Ratnaweera, Harsha Kalinowski, Slawomir A novel automatic flow method with direct-injection photometric detector for determination of dissolved reactive phosphorus in wastewater and freshwater samples |
title | A novel automatic flow method with direct-injection photometric detector for determination of dissolved reactive phosphorus in wastewater and freshwater samples |
title_full | A novel automatic flow method with direct-injection photometric detector for determination of dissolved reactive phosphorus in wastewater and freshwater samples |
title_fullStr | A novel automatic flow method with direct-injection photometric detector for determination of dissolved reactive phosphorus in wastewater and freshwater samples |
title_full_unstemmed | A novel automatic flow method with direct-injection photometric detector for determination of dissolved reactive phosphorus in wastewater and freshwater samples |
title_short | A novel automatic flow method with direct-injection photometric detector for determination of dissolved reactive phosphorus in wastewater and freshwater samples |
title_sort | novel automatic flow method with direct-injection photometric detector for determination of dissolved reactive phosphorus in wastewater and freshwater samples |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5809572/ https://www.ncbi.nlm.nih.gov/pubmed/29435674 http://dx.doi.org/10.1007/s10661-018-6511-z |
work_keys_str_mv | AT koronkiewiczstanislawa anovelautomaticflowmethodwithdirectinjectionphotometricdetectorfordeterminationofdissolvedreactivephosphorusinwastewaterandfreshwatersamples AT trifescumihaela anovelautomaticflowmethodwithdirectinjectionphotometricdetectorfordeterminationofdissolvedreactivephosphorusinwastewaterandfreshwatersamples AT smoczynskilech anovelautomaticflowmethodwithdirectinjectionphotometricdetectorfordeterminationofdissolvedreactivephosphorusinwastewaterandfreshwatersamples AT ratnaweeraharsha anovelautomaticflowmethodwithdirectinjectionphotometricdetectorfordeterminationofdissolvedreactivephosphorusinwastewaterandfreshwatersamples AT kalinowskislawomir anovelautomaticflowmethodwithdirectinjectionphotometricdetectorfordeterminationofdissolvedreactivephosphorusinwastewaterandfreshwatersamples AT koronkiewiczstanislawa novelautomaticflowmethodwithdirectinjectionphotometricdetectorfordeterminationofdissolvedreactivephosphorusinwastewaterandfreshwatersamples AT trifescumihaela novelautomaticflowmethodwithdirectinjectionphotometricdetectorfordeterminationofdissolvedreactivephosphorusinwastewaterandfreshwatersamples AT smoczynskilech novelautomaticflowmethodwithdirectinjectionphotometricdetectorfordeterminationofdissolvedreactivephosphorusinwastewaterandfreshwatersamples AT ratnaweeraharsha novelautomaticflowmethodwithdirectinjectionphotometricdetectorfordeterminationofdissolvedreactivephosphorusinwastewaterandfreshwatersamples AT kalinowskislawomir novelautomaticflowmethodwithdirectinjectionphotometricdetectorfordeterminationofdissolvedreactivephosphorusinwastewaterandfreshwatersamples |