Cargando…
Dynamic (1)H imaging of hyperpolarized [1‐(13)C]lactate in vivo using a reverse INEPT experiment
PURPOSE: Dynamic magnetic resonance spectroscopic imaging of hyperpolarized (13)C‐labeled cell substrates has enabled the investigation of tissue metabolism in vivo. Currently observation of these hyperpolarized substrates is limited mainly to (13)C detection. We describe here an imaging pulse seque...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
John Wiley and Sons Inc.
2017
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5811914/ https://www.ncbi.nlm.nih.gov/pubmed/28474393 http://dx.doi.org/10.1002/mrm.26725 |
_version_ | 1783299939591258112 |
---|---|
author | Wang, Jiazheng Kreis, Felix Wright, Alan J. Hesketh, Richard L. Levitt, Malcolm H. Brindle, Kevin M. |
author_facet | Wang, Jiazheng Kreis, Felix Wright, Alan J. Hesketh, Richard L. Levitt, Malcolm H. Brindle, Kevin M. |
author_sort | Wang, Jiazheng |
collection | PubMed |
description | PURPOSE: Dynamic magnetic resonance spectroscopic imaging of hyperpolarized (13)C‐labeled cell substrates has enabled the investigation of tissue metabolism in vivo. Currently observation of these hyperpolarized substrates is limited mainly to (13)C detection. We describe here an imaging pulse sequence that enables proton observation by using polarization transfer from the hyperpolarized (13)C nucleus to spin‐coupled protons. METHODS: The pulse sequence transfers (13)C hyperpolarization to (1)H using a modified reverse insensitive nuclei enhanced by polarization transfer (INEPT) sequence that acquires a fully refocused echo. The resulting hyperpolarized (1)H signal is acquired using a 2D echo‐planar trajectory. The efficiency of polarization transfer was investigated using simulations with and without T(1) and T(2) relaxation of both the (1)H and (13)C nuclei. RESULTS: Simulations showed that (1)H detection of the hyperpolarized (13)C nucleus in lactate should increase significantly the signal‐to‐noise ratio when compared with direct (13)C detection at 3T. However the advantage of (1)H detection is expected to disappear at higher fields. Dynamic (1)H images of hyperpolarized [1‐(13)C]lactate, with a spatial resolution of 1.25 × 1.25 mm(2), were acquired from a phantom injected with hyperpolarized [1‐(13)C]lactate and from tumors in vivo following injection of hyperpolarized [1‐(13)C]pyruvate. CONCLUSIONS: The sequence allows (1)H imaging of hyperpolarized (13)C‐labeled substrates in vivo. Magn Reson Med 79:741–747, 2018. © 2017 The Authors Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine. This is an open access article under the terms of the Creative Commons Attribution License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited. |
format | Online Article Text |
id | pubmed-5811914 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2017 |
publisher | John Wiley and Sons Inc. |
record_format | MEDLINE/PubMed |
spelling | pubmed-58119142018-02-16 Dynamic (1)H imaging of hyperpolarized [1‐(13)C]lactate in vivo using a reverse INEPT experiment Wang, Jiazheng Kreis, Felix Wright, Alan J. Hesketh, Richard L. Levitt, Malcolm H. Brindle, Kevin M. Magn Reson Med Full Papers—Imaging Methodology PURPOSE: Dynamic magnetic resonance spectroscopic imaging of hyperpolarized (13)C‐labeled cell substrates has enabled the investigation of tissue metabolism in vivo. Currently observation of these hyperpolarized substrates is limited mainly to (13)C detection. We describe here an imaging pulse sequence that enables proton observation by using polarization transfer from the hyperpolarized (13)C nucleus to spin‐coupled protons. METHODS: The pulse sequence transfers (13)C hyperpolarization to (1)H using a modified reverse insensitive nuclei enhanced by polarization transfer (INEPT) sequence that acquires a fully refocused echo. The resulting hyperpolarized (1)H signal is acquired using a 2D echo‐planar trajectory. The efficiency of polarization transfer was investigated using simulations with and without T(1) and T(2) relaxation of both the (1)H and (13)C nuclei. RESULTS: Simulations showed that (1)H detection of the hyperpolarized (13)C nucleus in lactate should increase significantly the signal‐to‐noise ratio when compared with direct (13)C detection at 3T. However the advantage of (1)H detection is expected to disappear at higher fields. Dynamic (1)H images of hyperpolarized [1‐(13)C]lactate, with a spatial resolution of 1.25 × 1.25 mm(2), were acquired from a phantom injected with hyperpolarized [1‐(13)C]lactate and from tumors in vivo following injection of hyperpolarized [1‐(13)C]pyruvate. CONCLUSIONS: The sequence allows (1)H imaging of hyperpolarized (13)C‐labeled substrates in vivo. Magn Reson Med 79:741–747, 2018. © 2017 The Authors Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine. This is an open access article under the terms of the Creative Commons Attribution License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited. John Wiley and Sons Inc. 2017-05-05 2018-02 /pmc/articles/PMC5811914/ /pubmed/28474393 http://dx.doi.org/10.1002/mrm.26725 Text en © 2017 The Authors Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine This is an open access article under the terms of the Creative Commons Attribution (http://creativecommons.org/licenses/by/4.0/) License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Full Papers—Imaging Methodology Wang, Jiazheng Kreis, Felix Wright, Alan J. Hesketh, Richard L. Levitt, Malcolm H. Brindle, Kevin M. Dynamic (1)H imaging of hyperpolarized [1‐(13)C]lactate in vivo using a reverse INEPT experiment |
title | Dynamic (1)H imaging of hyperpolarized [1‐(13)C]lactate in vivo using a reverse INEPT experiment |
title_full | Dynamic (1)H imaging of hyperpolarized [1‐(13)C]lactate in vivo using a reverse INEPT experiment |
title_fullStr | Dynamic (1)H imaging of hyperpolarized [1‐(13)C]lactate in vivo using a reverse INEPT experiment |
title_full_unstemmed | Dynamic (1)H imaging of hyperpolarized [1‐(13)C]lactate in vivo using a reverse INEPT experiment |
title_short | Dynamic (1)H imaging of hyperpolarized [1‐(13)C]lactate in vivo using a reverse INEPT experiment |
title_sort | dynamic (1)h imaging of hyperpolarized [1‐(13)c]lactate in vivo using a reverse inept experiment |
topic | Full Papers—Imaging Methodology |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5811914/ https://www.ncbi.nlm.nih.gov/pubmed/28474393 http://dx.doi.org/10.1002/mrm.26725 |
work_keys_str_mv | AT wangjiazheng dynamic1himagingofhyperpolarized113clactateinvivousingareverseineptexperiment AT kreisfelix dynamic1himagingofhyperpolarized113clactateinvivousingareverseineptexperiment AT wrightalanj dynamic1himagingofhyperpolarized113clactateinvivousingareverseineptexperiment AT heskethrichardl dynamic1himagingofhyperpolarized113clactateinvivousingareverseineptexperiment AT levittmalcolmh dynamic1himagingofhyperpolarized113clactateinvivousingareverseineptexperiment AT brindlekevinm dynamic1himagingofhyperpolarized113clactateinvivousingareverseineptexperiment |