Cargando…

Dynamic (1)H imaging of hyperpolarized [1‐(13)C]lactate in vivo using a reverse INEPT experiment

PURPOSE: Dynamic magnetic resonance spectroscopic imaging of hyperpolarized (13)C‐labeled cell substrates has enabled the investigation of tissue metabolism in vivo. Currently observation of these hyperpolarized substrates is limited mainly to (13)C detection. We describe here an imaging pulse seque...

Descripción completa

Detalles Bibliográficos
Autores principales: Wang, Jiazheng, Kreis, Felix, Wright, Alan J., Hesketh, Richard L., Levitt, Malcolm H., Brindle, Kevin M.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5811914/
https://www.ncbi.nlm.nih.gov/pubmed/28474393
http://dx.doi.org/10.1002/mrm.26725
_version_ 1783299939591258112
author Wang, Jiazheng
Kreis, Felix
Wright, Alan J.
Hesketh, Richard L.
Levitt, Malcolm H.
Brindle, Kevin M.
author_facet Wang, Jiazheng
Kreis, Felix
Wright, Alan J.
Hesketh, Richard L.
Levitt, Malcolm H.
Brindle, Kevin M.
author_sort Wang, Jiazheng
collection PubMed
description PURPOSE: Dynamic magnetic resonance spectroscopic imaging of hyperpolarized (13)C‐labeled cell substrates has enabled the investigation of tissue metabolism in vivo. Currently observation of these hyperpolarized substrates is limited mainly to (13)C detection. We describe here an imaging pulse sequence that enables proton observation by using polarization transfer from the hyperpolarized (13)C nucleus to spin‐coupled protons. METHODS: The pulse sequence transfers (13)C hyperpolarization to (1)H using a modified reverse insensitive nuclei enhanced by polarization transfer (INEPT) sequence that acquires a fully refocused echo. The resulting hyperpolarized (1)H signal is acquired using a 2D echo‐planar trajectory. The efficiency of polarization transfer was investigated using simulations with and without T(1) and T(2) relaxation of both the (1)H and (13)C nuclei. RESULTS: Simulations showed that (1)H detection of the hyperpolarized (13)C nucleus in lactate should increase significantly the signal‐to‐noise ratio when compared with direct (13)C detection at 3T. However the advantage of (1)H detection is expected to disappear at higher fields. Dynamic (1)H images of hyperpolarized [1‐(13)C]lactate, with a spatial resolution of 1.25 × 1.25 mm(2), were acquired from a phantom injected with hyperpolarized [1‐(13)C]lactate and from tumors in vivo following injection of hyperpolarized [1‐(13)C]pyruvate. CONCLUSIONS: The sequence allows (1)H imaging of hyperpolarized (13)C‐labeled substrates in vivo. Magn Reson Med 79:741–747, 2018. © 2017 The Authors Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine. This is an open access article under the terms of the Creative Commons Attribution License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
format Online
Article
Text
id pubmed-5811914
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-58119142018-02-16 Dynamic (1)H imaging of hyperpolarized [1‐(13)C]lactate in vivo using a reverse INEPT experiment Wang, Jiazheng Kreis, Felix Wright, Alan J. Hesketh, Richard L. Levitt, Malcolm H. Brindle, Kevin M. Magn Reson Med Full Papers—Imaging Methodology PURPOSE: Dynamic magnetic resonance spectroscopic imaging of hyperpolarized (13)C‐labeled cell substrates has enabled the investigation of tissue metabolism in vivo. Currently observation of these hyperpolarized substrates is limited mainly to (13)C detection. We describe here an imaging pulse sequence that enables proton observation by using polarization transfer from the hyperpolarized (13)C nucleus to spin‐coupled protons. METHODS: The pulse sequence transfers (13)C hyperpolarization to (1)H using a modified reverse insensitive nuclei enhanced by polarization transfer (INEPT) sequence that acquires a fully refocused echo. The resulting hyperpolarized (1)H signal is acquired using a 2D echo‐planar trajectory. The efficiency of polarization transfer was investigated using simulations with and without T(1) and T(2) relaxation of both the (1)H and (13)C nuclei. RESULTS: Simulations showed that (1)H detection of the hyperpolarized (13)C nucleus in lactate should increase significantly the signal‐to‐noise ratio when compared with direct (13)C detection at 3T. However the advantage of (1)H detection is expected to disappear at higher fields. Dynamic (1)H images of hyperpolarized [1‐(13)C]lactate, with a spatial resolution of 1.25 × 1.25 mm(2), were acquired from a phantom injected with hyperpolarized [1‐(13)C]lactate and from tumors in vivo following injection of hyperpolarized [1‐(13)C]pyruvate. CONCLUSIONS: The sequence allows (1)H imaging of hyperpolarized (13)C‐labeled substrates in vivo. Magn Reson Med 79:741–747, 2018. © 2017 The Authors Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine. This is an open access article under the terms of the Creative Commons Attribution License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited. John Wiley and Sons Inc. 2017-05-05 2018-02 /pmc/articles/PMC5811914/ /pubmed/28474393 http://dx.doi.org/10.1002/mrm.26725 Text en © 2017 The Authors Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine This is an open access article under the terms of the Creative Commons Attribution (http://creativecommons.org/licenses/by/4.0/) License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
spellingShingle Full Papers—Imaging Methodology
Wang, Jiazheng
Kreis, Felix
Wright, Alan J.
Hesketh, Richard L.
Levitt, Malcolm H.
Brindle, Kevin M.
Dynamic (1)H imaging of hyperpolarized [1‐(13)C]lactate in vivo using a reverse INEPT experiment
title Dynamic (1)H imaging of hyperpolarized [1‐(13)C]lactate in vivo using a reverse INEPT experiment
title_full Dynamic (1)H imaging of hyperpolarized [1‐(13)C]lactate in vivo using a reverse INEPT experiment
title_fullStr Dynamic (1)H imaging of hyperpolarized [1‐(13)C]lactate in vivo using a reverse INEPT experiment
title_full_unstemmed Dynamic (1)H imaging of hyperpolarized [1‐(13)C]lactate in vivo using a reverse INEPT experiment
title_short Dynamic (1)H imaging of hyperpolarized [1‐(13)C]lactate in vivo using a reverse INEPT experiment
title_sort dynamic (1)h imaging of hyperpolarized [1‐(13)c]lactate in vivo using a reverse inept experiment
topic Full Papers—Imaging Methodology
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5811914/
https://www.ncbi.nlm.nih.gov/pubmed/28474393
http://dx.doi.org/10.1002/mrm.26725
work_keys_str_mv AT wangjiazheng dynamic1himagingofhyperpolarized113clactateinvivousingareverseineptexperiment
AT kreisfelix dynamic1himagingofhyperpolarized113clactateinvivousingareverseineptexperiment
AT wrightalanj dynamic1himagingofhyperpolarized113clactateinvivousingareverseineptexperiment
AT heskethrichardl dynamic1himagingofhyperpolarized113clactateinvivousingareverseineptexperiment
AT levittmalcolmh dynamic1himagingofhyperpolarized113clactateinvivousingareverseineptexperiment
AT brindlekevinm dynamic1himagingofhyperpolarized113clactateinvivousingareverseineptexperiment