Cargando…

Ocular dimensions of the Chinese adolescents with keratoconus

BACKGROUND: Adolescent KC is a special segment of the general KC population because an adolescents’s eyes are still susceptible to blurred vision and optical defocus during the sensitive period of ocular and visual development. In the present study, we evaluated the ocular dimensions of 53 KC adoles...

Descripción completa

Detalles Bibliográficos
Autores principales: Jian, Weijun, Shen, Yang, Chen, Yingjun, Tian, Mi, Zhou, Xingtao
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5812040/
https://www.ncbi.nlm.nih.gov/pubmed/29439700
http://dx.doi.org/10.1186/s12886-018-0713-6
_version_ 1783299963718991872
author Jian, Weijun
Shen, Yang
Chen, Yingjun
Tian, Mi
Zhou, Xingtao
author_facet Jian, Weijun
Shen, Yang
Chen, Yingjun
Tian, Mi
Zhou, Xingtao
author_sort Jian, Weijun
collection PubMed
description BACKGROUND: Adolescent KC is a special segment of the general KC population because an adolescents’s eyes are still susceptible to blurred vision and optical defocus during the sensitive period of ocular and visual development. In the present study, we evaluated the ocular dimensions of 53 KC adolescents. METHODS: One hundred and six KC eyes of 53 (42 boys and 11 girls) KC adolescents (age 15.5 ± 1.7 years, range 11 to 18) were involved in this retrospective study. The eye with more severe KC (Severe Group) of each patient was compared with their less affected eye (Mild Group). Optical axial length (OAL) was measured by optical coherence biometry (IOL-master). Central corneal thickness, anterior chamber depth (ACD), flat keratometry value, steep keratometry value, and maximum keratometry value were assessed with an anterior segment analyzer (Pentacam HR). Anterior segment length (ASL) was manually measured from the 25 scheimpflug images captured by the Pentacam HR with the mean value recorded. The posterior segment length (PSL) was calculated with the formula “PSL = OAL-ASL”. RESULTS: The mean ACD, OAL, ASL, and PSL values of the Severe Group were 3.51 ± 0.32 mm, 24.76 ± 1.24 mm, 4.01 ± 0.30 mm and 20.76 ± 1.15 mm.While those of the Mild Group were 3.36 ± 0.29 mm, 24.97 ± 1.40 mm, 3.94 ± 0.35 mm and 21.03 ± 1.31 mm. The Severe Group has significantly higher ACD (t = 4.539, P < 0.001) value but lower OAL (t = − 3.120, P = 0.003) and PSL (t = − 4.537, P < 0.001) values when compared with those of the Mild Group. For the Severe Group, the Kmax values were significantly correlated with the SE values (R = − 0.385, P = 0.004), the ACD values (R = 0.375, P = 0.006), the ASL values (R = 0.308, P = 0.025) and the PSL values (R = − 0.317, P = 0.021), but not with the OAL values (R = − 0.220, P = 0.114). In the Mild Group, the Kmax values were negatively correlated with the SE (R = − 0.577, P < 0.001), OAL(R = − 0.533, P < 0.001), and PSL (R = − 0.523, P < 0.001) values, but not with ACD (R = − 0.110, P = 0.434) or ASL (R = − 0.182, P = 0.192) values. CONCLUSIONS: For adolescent KC, the more keratoconic eyes may be characterized by deeper ACD but shorter OAL and PSL, when compared with the less affected ones.
format Online
Article
Text
id pubmed-5812040
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-58120402018-02-15 Ocular dimensions of the Chinese adolescents with keratoconus Jian, Weijun Shen, Yang Chen, Yingjun Tian, Mi Zhou, Xingtao BMC Ophthalmol Research Article BACKGROUND: Adolescent KC is a special segment of the general KC population because an adolescents’s eyes are still susceptible to blurred vision and optical defocus during the sensitive period of ocular and visual development. In the present study, we evaluated the ocular dimensions of 53 KC adolescents. METHODS: One hundred and six KC eyes of 53 (42 boys and 11 girls) KC adolescents (age 15.5 ± 1.7 years, range 11 to 18) were involved in this retrospective study. The eye with more severe KC (Severe Group) of each patient was compared with their less affected eye (Mild Group). Optical axial length (OAL) was measured by optical coherence biometry (IOL-master). Central corneal thickness, anterior chamber depth (ACD), flat keratometry value, steep keratometry value, and maximum keratometry value were assessed with an anterior segment analyzer (Pentacam HR). Anterior segment length (ASL) was manually measured from the 25 scheimpflug images captured by the Pentacam HR with the mean value recorded. The posterior segment length (PSL) was calculated with the formula “PSL = OAL-ASL”. RESULTS: The mean ACD, OAL, ASL, and PSL values of the Severe Group were 3.51 ± 0.32 mm, 24.76 ± 1.24 mm, 4.01 ± 0.30 mm and 20.76 ± 1.15 mm.While those of the Mild Group were 3.36 ± 0.29 mm, 24.97 ± 1.40 mm, 3.94 ± 0.35 mm and 21.03 ± 1.31 mm. The Severe Group has significantly higher ACD (t = 4.539, P < 0.001) value but lower OAL (t = − 3.120, P = 0.003) and PSL (t = − 4.537, P < 0.001) values when compared with those of the Mild Group. For the Severe Group, the Kmax values were significantly correlated with the SE values (R = − 0.385, P = 0.004), the ACD values (R = 0.375, P = 0.006), the ASL values (R = 0.308, P = 0.025) and the PSL values (R = − 0.317, P = 0.021), but not with the OAL values (R = − 0.220, P = 0.114). In the Mild Group, the Kmax values were negatively correlated with the SE (R = − 0.577, P < 0.001), OAL(R = − 0.533, P < 0.001), and PSL (R = − 0.523, P < 0.001) values, but not with ACD (R = − 0.110, P = 0.434) or ASL (R = − 0.182, P = 0.192) values. CONCLUSIONS: For adolescent KC, the more keratoconic eyes may be characterized by deeper ACD but shorter OAL and PSL, when compared with the less affected ones. BioMed Central 2018-02-13 /pmc/articles/PMC5812040/ /pubmed/29439700 http://dx.doi.org/10.1186/s12886-018-0713-6 Text en © The Author(s). 2018 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Research Article
Jian, Weijun
Shen, Yang
Chen, Yingjun
Tian, Mi
Zhou, Xingtao
Ocular dimensions of the Chinese adolescents with keratoconus
title Ocular dimensions of the Chinese adolescents with keratoconus
title_full Ocular dimensions of the Chinese adolescents with keratoconus
title_fullStr Ocular dimensions of the Chinese adolescents with keratoconus
title_full_unstemmed Ocular dimensions of the Chinese adolescents with keratoconus
title_short Ocular dimensions of the Chinese adolescents with keratoconus
title_sort ocular dimensions of the chinese adolescents with keratoconus
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5812040/
https://www.ncbi.nlm.nih.gov/pubmed/29439700
http://dx.doi.org/10.1186/s12886-018-0713-6
work_keys_str_mv AT jianweijun oculardimensionsofthechineseadolescentswithkeratoconus
AT shenyang oculardimensionsofthechineseadolescentswithkeratoconus
AT chenyingjun oculardimensionsofthechineseadolescentswithkeratoconus
AT tianmi oculardimensionsofthechineseadolescentswithkeratoconus
AT zhouxingtao oculardimensionsofthechineseadolescentswithkeratoconus