Cargando…

3D analysis of Osteosyntheses material using semi-automated CT segmentation: a case series of a 4 corner fusion plate

BACKROUND: Scaphoidectomy and midcarpal fusion can be performed using traditional fixation methods like K-wires, staples, screws or different dorsal (non)locking arthrodesis systems. The aim of this study is to test the Aptus four corner locking plate and to compare the clinical findings to the data...

Descripción completa

Detalles Bibliográficos
Autores principales: Woehl, Rebecca, Maier, Johannes, Gehmert, Sebastian, Palm, Christoph, Riebschlaeger, Birgit, Nerlich, Michael, Huber, Michaela
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5812049/
https://www.ncbi.nlm.nih.gov/pubmed/29439687
http://dx.doi.org/10.1186/s12891-018-1975-0
_version_ 1783299966055219200
author Woehl, Rebecca
Maier, Johannes
Gehmert, Sebastian
Palm, Christoph
Riebschlaeger, Birgit
Nerlich, Michael
Huber, Michaela
author_facet Woehl, Rebecca
Maier, Johannes
Gehmert, Sebastian
Palm, Christoph
Riebschlaeger, Birgit
Nerlich, Michael
Huber, Michaela
author_sort Woehl, Rebecca
collection PubMed
description BACKROUND: Scaphoidectomy and midcarpal fusion can be performed using traditional fixation methods like K-wires, staples, screws or different dorsal (non)locking arthrodesis systems. The aim of this study is to test the Aptus four corner locking plate and to compare the clinical findings to the data revealed by CT scans and semi-automated segmentation. METHODS: This is a retrospective review of eleven patients suffering from scapholunate advanced collapse (SLAC) or scaphoid non-union advanced collapse (SNAC) wrist, who received a four corner fusion between August 2011 and July 2014. The clinical evaluation consisted of measuring the range of motion (ROM), strength and pain on a visual analogue scale (VAS). Additionally, the Disabilities of the Arm, Shoulder and Hand (QuickDASH) and the Mayo Wrist Score were assessed. A computerized tomography (CT) of the wrist was obtained six weeks postoperatively. After semi-automated segmentation of the CT scans, the models were post processed and surveyed. RESULTS: During the six-month follow-up mean range of motion (ROM) of the operated wrist was 60°, consisting of 30° extension and 30° flexion. While pain levels decreased significantly, 54% of grip strength and 89% of pinch strength were preserved compared to the contralateral healthy wrist. Union could be detected in all CT scans of the wrist. While X-ray pictures obtained postoperatively revealed no pathology, two user related technical complications were found through the 3D analysis, which correlated to the clinical outcome. CONCLUSION: Due to semi-automated segmentation and 3D analysis it has been proved that the plate design can keep up to the manufacturers’ promises. Over all, this case series confirmed that the plate can compete with the coexisting techniques concerning clinical outcome, union and complication rate.
format Online
Article
Text
id pubmed-5812049
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-58120492018-02-15 3D analysis of Osteosyntheses material using semi-automated CT segmentation: a case series of a 4 corner fusion plate Woehl, Rebecca Maier, Johannes Gehmert, Sebastian Palm, Christoph Riebschlaeger, Birgit Nerlich, Michael Huber, Michaela BMC Musculoskelet Disord Research Article BACKROUND: Scaphoidectomy and midcarpal fusion can be performed using traditional fixation methods like K-wires, staples, screws or different dorsal (non)locking arthrodesis systems. The aim of this study is to test the Aptus four corner locking plate and to compare the clinical findings to the data revealed by CT scans and semi-automated segmentation. METHODS: This is a retrospective review of eleven patients suffering from scapholunate advanced collapse (SLAC) or scaphoid non-union advanced collapse (SNAC) wrist, who received a four corner fusion between August 2011 and July 2014. The clinical evaluation consisted of measuring the range of motion (ROM), strength and pain on a visual analogue scale (VAS). Additionally, the Disabilities of the Arm, Shoulder and Hand (QuickDASH) and the Mayo Wrist Score were assessed. A computerized tomography (CT) of the wrist was obtained six weeks postoperatively. After semi-automated segmentation of the CT scans, the models were post processed and surveyed. RESULTS: During the six-month follow-up mean range of motion (ROM) of the operated wrist was 60°, consisting of 30° extension and 30° flexion. While pain levels decreased significantly, 54% of grip strength and 89% of pinch strength were preserved compared to the contralateral healthy wrist. Union could be detected in all CT scans of the wrist. While X-ray pictures obtained postoperatively revealed no pathology, two user related technical complications were found through the 3D analysis, which correlated to the clinical outcome. CONCLUSION: Due to semi-automated segmentation and 3D analysis it has been proved that the plate design can keep up to the manufacturers’ promises. Over all, this case series confirmed that the plate can compete with the coexisting techniques concerning clinical outcome, union and complication rate. BioMed Central 2018-02-13 /pmc/articles/PMC5812049/ /pubmed/29439687 http://dx.doi.org/10.1186/s12891-018-1975-0 Text en © The Author(s). 2018 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Research Article
Woehl, Rebecca
Maier, Johannes
Gehmert, Sebastian
Palm, Christoph
Riebschlaeger, Birgit
Nerlich, Michael
Huber, Michaela
3D analysis of Osteosyntheses material using semi-automated CT segmentation: a case series of a 4 corner fusion plate
title 3D analysis of Osteosyntheses material using semi-automated CT segmentation: a case series of a 4 corner fusion plate
title_full 3D analysis of Osteosyntheses material using semi-automated CT segmentation: a case series of a 4 corner fusion plate
title_fullStr 3D analysis of Osteosyntheses material using semi-automated CT segmentation: a case series of a 4 corner fusion plate
title_full_unstemmed 3D analysis of Osteosyntheses material using semi-automated CT segmentation: a case series of a 4 corner fusion plate
title_short 3D analysis of Osteosyntheses material using semi-automated CT segmentation: a case series of a 4 corner fusion plate
title_sort 3d analysis of osteosyntheses material using semi-automated ct segmentation: a case series of a 4 corner fusion plate
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5812049/
https://www.ncbi.nlm.nih.gov/pubmed/29439687
http://dx.doi.org/10.1186/s12891-018-1975-0
work_keys_str_mv AT woehlrebecca 3danalysisofosteosynthesesmaterialusingsemiautomatedctsegmentationacaseseriesofa4cornerfusionplate
AT maierjohannes 3danalysisofosteosynthesesmaterialusingsemiautomatedctsegmentationacaseseriesofa4cornerfusionplate
AT gehmertsebastian 3danalysisofosteosynthesesmaterialusingsemiautomatedctsegmentationacaseseriesofa4cornerfusionplate
AT palmchristoph 3danalysisofosteosynthesesmaterialusingsemiautomatedctsegmentationacaseseriesofa4cornerfusionplate
AT riebschlaegerbirgit 3danalysisofosteosynthesesmaterialusingsemiautomatedctsegmentationacaseseriesofa4cornerfusionplate
AT nerlichmichael 3danalysisofosteosynthesesmaterialusingsemiautomatedctsegmentationacaseseriesofa4cornerfusionplate
AT hubermichaela 3danalysisofosteosynthesesmaterialusingsemiautomatedctsegmentationacaseseriesofa4cornerfusionplate