Cargando…

Prediction of small for size syndrome after extended hepatectomy: Tissue characterization by relaxometry, diffusion weighted magnetic resonance imaging and magnetization transfer

This study aimed to monitor the course of liver regeneration by multiparametric magnetic-resonance imaging (MRI) after partial liver resection characterizing Small-for-Size Syndrome (SFSS), which frequently leads to fatal post-hepatectomy liver failure (PLF). Twenty-two C57BL/6 mice underwent either...

Descripción completa

Detalles Bibliográficos
Autores principales: Eberhardt, Christian, Wurnig, Moritz C., Wirsching, Andrea, Rossi, Cristina, Feldmane, Idana, Lesurtel, Mickael, Boss, Andreas
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5812661/
https://www.ncbi.nlm.nih.gov/pubmed/29444146
http://dx.doi.org/10.1371/journal.pone.0192847
_version_ 1783300071345881088
author Eberhardt, Christian
Wurnig, Moritz C.
Wirsching, Andrea
Rossi, Cristina
Feldmane, Idana
Lesurtel, Mickael
Boss, Andreas
author_facet Eberhardt, Christian
Wurnig, Moritz C.
Wirsching, Andrea
Rossi, Cristina
Feldmane, Idana
Lesurtel, Mickael
Boss, Andreas
author_sort Eberhardt, Christian
collection PubMed
description This study aimed to monitor the course of liver regeneration by multiparametric magnetic-resonance imaging (MRI) after partial liver resection characterizing Small-for-Size Syndrome (SFSS), which frequently leads to fatal post-hepatectomy liver failure (PLF). Twenty-two C57BL/6 mice underwent either conventional 70% partial hepatectomy (cPH), extended 86% partial hepatectomy (ePH) or SHAM operation. Subsequent MRI scans on days 0, 1, 2, 3, 5 and 7 in a 4.7T MR Scanner quantified longitudinal and transverse relaxation times, apparent diffusion coefficient (ADC) and the magnetization-transfer ratio (MTR) of the regenerating liver parenchyma. Histological examination was performed by hematoxylin-eosin staining. After hepatectomy, an increase of T1 time was detected being larger for ePH on day 1: 18% for cPH vs. 40% for ePH and on day 2: 24% for cPH vs. 49% for ePH. An increase in T2 time, again greater in ePH was most pronounced on day 5: 21% for cPH vs. 41% for ePH. ADC and MTR showed a decrease on day 1: 21% for ePH vs. 13% for cPH for ADC, 15% for ePH vs. 11% for cPH for MTR. Subsequently, all MR parameters converged towards initial values in surviving animals. Dying PLF animals exhibited the strongest increase of T1 relaxation time and most prominent decreases of ADC and MTR. The retrieved MRI biomarkers indicate SFSS and potentially developing PLF at an early stage, likely reflecting cellular hypertrophy with extended water content and concomitantly diluted cellular components as features of liver regeneration, appearing more intense in ePH as compared to cPH.
format Online
Article
Text
id pubmed-5812661
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-58126612018-02-28 Prediction of small for size syndrome after extended hepatectomy: Tissue characterization by relaxometry, diffusion weighted magnetic resonance imaging and magnetization transfer Eberhardt, Christian Wurnig, Moritz C. Wirsching, Andrea Rossi, Cristina Feldmane, Idana Lesurtel, Mickael Boss, Andreas PLoS One Research Article This study aimed to monitor the course of liver regeneration by multiparametric magnetic-resonance imaging (MRI) after partial liver resection characterizing Small-for-Size Syndrome (SFSS), which frequently leads to fatal post-hepatectomy liver failure (PLF). Twenty-two C57BL/6 mice underwent either conventional 70% partial hepatectomy (cPH), extended 86% partial hepatectomy (ePH) or SHAM operation. Subsequent MRI scans on days 0, 1, 2, 3, 5 and 7 in a 4.7T MR Scanner quantified longitudinal and transverse relaxation times, apparent diffusion coefficient (ADC) and the magnetization-transfer ratio (MTR) of the regenerating liver parenchyma. Histological examination was performed by hematoxylin-eosin staining. After hepatectomy, an increase of T1 time was detected being larger for ePH on day 1: 18% for cPH vs. 40% for ePH and on day 2: 24% for cPH vs. 49% for ePH. An increase in T2 time, again greater in ePH was most pronounced on day 5: 21% for cPH vs. 41% for ePH. ADC and MTR showed a decrease on day 1: 21% for ePH vs. 13% for cPH for ADC, 15% for ePH vs. 11% for cPH for MTR. Subsequently, all MR parameters converged towards initial values in surviving animals. Dying PLF animals exhibited the strongest increase of T1 relaxation time and most prominent decreases of ADC and MTR. The retrieved MRI biomarkers indicate SFSS and potentially developing PLF at an early stage, likely reflecting cellular hypertrophy with extended water content and concomitantly diluted cellular components as features of liver regeneration, appearing more intense in ePH as compared to cPH. Public Library of Science 2018-02-14 /pmc/articles/PMC5812661/ /pubmed/29444146 http://dx.doi.org/10.1371/journal.pone.0192847 Text en © 2018 Eberhardt et al http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Research Article
Eberhardt, Christian
Wurnig, Moritz C.
Wirsching, Andrea
Rossi, Cristina
Feldmane, Idana
Lesurtel, Mickael
Boss, Andreas
Prediction of small for size syndrome after extended hepatectomy: Tissue characterization by relaxometry, diffusion weighted magnetic resonance imaging and magnetization transfer
title Prediction of small for size syndrome after extended hepatectomy: Tissue characterization by relaxometry, diffusion weighted magnetic resonance imaging and magnetization transfer
title_full Prediction of small for size syndrome after extended hepatectomy: Tissue characterization by relaxometry, diffusion weighted magnetic resonance imaging and magnetization transfer
title_fullStr Prediction of small for size syndrome after extended hepatectomy: Tissue characterization by relaxometry, diffusion weighted magnetic resonance imaging and magnetization transfer
title_full_unstemmed Prediction of small for size syndrome after extended hepatectomy: Tissue characterization by relaxometry, diffusion weighted magnetic resonance imaging and magnetization transfer
title_short Prediction of small for size syndrome after extended hepatectomy: Tissue characterization by relaxometry, diffusion weighted magnetic resonance imaging and magnetization transfer
title_sort prediction of small for size syndrome after extended hepatectomy: tissue characterization by relaxometry, diffusion weighted magnetic resonance imaging and magnetization transfer
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5812661/
https://www.ncbi.nlm.nih.gov/pubmed/29444146
http://dx.doi.org/10.1371/journal.pone.0192847
work_keys_str_mv AT eberhardtchristian predictionofsmallforsizesyndromeafterextendedhepatectomytissuecharacterizationbyrelaxometrydiffusionweightedmagneticresonanceimagingandmagnetizationtransfer
AT wurnigmoritzc predictionofsmallforsizesyndromeafterextendedhepatectomytissuecharacterizationbyrelaxometrydiffusionweightedmagneticresonanceimagingandmagnetizationtransfer
AT wirschingandrea predictionofsmallforsizesyndromeafterextendedhepatectomytissuecharacterizationbyrelaxometrydiffusionweightedmagneticresonanceimagingandmagnetizationtransfer
AT rossicristina predictionofsmallforsizesyndromeafterextendedhepatectomytissuecharacterizationbyrelaxometrydiffusionweightedmagneticresonanceimagingandmagnetizationtransfer
AT feldmaneidana predictionofsmallforsizesyndromeafterextendedhepatectomytissuecharacterizationbyrelaxometrydiffusionweightedmagneticresonanceimagingandmagnetizationtransfer
AT lesurtelmickael predictionofsmallforsizesyndromeafterextendedhepatectomytissuecharacterizationbyrelaxometrydiffusionweightedmagneticresonanceimagingandmagnetizationtransfer
AT bossandreas predictionofsmallforsizesyndromeafterextendedhepatectomytissuecharacterizationbyrelaxometrydiffusionweightedmagneticresonanceimagingandmagnetizationtransfer