Cargando…
Effect of a moderate-intensity demonstration walk on accuracy of physical activity self-report
BACKGROUND/OBJECTIVE: Providing a demonstration of a 10-minute bout of moderate-to-vigorous intensity physical activity (MVPA) immediately prior to subjective reporting of MVPA could influence self-reported activity by calibrating both duration and intensity. We assessed the effect of a demonstratio...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
The Society of Chinese Scholars on Exercise Physiology and Fitness
2017
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5812854/ https://www.ncbi.nlm.nih.gov/pubmed/29541123 http://dx.doi.org/10.1016/j.jesf.2016.10.002 |
_version_ | 1783300079226978304 |
---|---|
author | Larsen, Britta A. Carr, Lucas J. Dunsiger, Shira Marcus, Bess H. |
author_facet | Larsen, Britta A. Carr, Lucas J. Dunsiger, Shira Marcus, Bess H. |
author_sort | Larsen, Britta A. |
collection | PubMed |
description | BACKGROUND/OBJECTIVE: Providing a demonstration of a 10-minute bout of moderate-to-vigorous intensity physical activity (MVPA) immediately prior to subjective reporting of MVPA could influence self-reported activity by calibrating both duration and intensity. We assessed the effect of a demonstration of MVPA on subsequent MVPA recall, and explored whether this improved agreement with objective measures of MVPA. METHODS: A total of 846 individuals participated in four different physical activity interventions; two of which included a 10-minute moderate-intensity demonstration walk on a treadmill at baseline and 6-month visits immediately prior to reporting MVPA. Participants from three studies also wore accelerometers during the week overlapping with self-reported MVPA. RESULTS: Overall, those completing the demonstration walk reported significantly fewer minutes of MVPA per week at baseline (b = −11.69, standard error = 2.53, p < 0.01). The effect of the demonstration walk at 6 months was not significant (p = 0.06). Correlations with accelerometers at baseline were higher in the two studies with the demonstration walk (ρ = 0.28, 0.26) than the study without (ρ = 0.04). Correlations with accelerometers increased overall from baseline to follow-up. CONCLUSION: A 10-minute demonstration of MVPA was associated with reporting fewer minutes of MVPA and improved agreement with objective PA measures at baseline. These findings support combining self-report PA assessments with hands-on MVPA demonstrations. |
format | Online Article Text |
id | pubmed-5812854 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2017 |
publisher | The Society of Chinese Scholars on Exercise Physiology and Fitness |
record_format | MEDLINE/PubMed |
spelling | pubmed-58128542018-03-14 Effect of a moderate-intensity demonstration walk on accuracy of physical activity self-report Larsen, Britta A. Carr, Lucas J. Dunsiger, Shira Marcus, Bess H. J Exerc Sci Fit Original Article BACKGROUND/OBJECTIVE: Providing a demonstration of a 10-minute bout of moderate-to-vigorous intensity physical activity (MVPA) immediately prior to subjective reporting of MVPA could influence self-reported activity by calibrating both duration and intensity. We assessed the effect of a demonstration of MVPA on subsequent MVPA recall, and explored whether this improved agreement with objective measures of MVPA. METHODS: A total of 846 individuals participated in four different physical activity interventions; two of which included a 10-minute moderate-intensity demonstration walk on a treadmill at baseline and 6-month visits immediately prior to reporting MVPA. Participants from three studies also wore accelerometers during the week overlapping with self-reported MVPA. RESULTS: Overall, those completing the demonstration walk reported significantly fewer minutes of MVPA per week at baseline (b = −11.69, standard error = 2.53, p < 0.01). The effect of the demonstration walk at 6 months was not significant (p = 0.06). Correlations with accelerometers at baseline were higher in the two studies with the demonstration walk (ρ = 0.28, 0.26) than the study without (ρ = 0.04). Correlations with accelerometers increased overall from baseline to follow-up. CONCLUSION: A 10-minute demonstration of MVPA was associated with reporting fewer minutes of MVPA and improved agreement with objective PA measures at baseline. These findings support combining self-report PA assessments with hands-on MVPA demonstrations. The Society of Chinese Scholars on Exercise Physiology and Fitness 2017-06 2016-12-18 /pmc/articles/PMC5812854/ /pubmed/29541123 http://dx.doi.org/10.1016/j.jesf.2016.10.002 Text en Copyright © 2016, The Society of Chinese Scholars on Exercise Physiology and Fitness. Published by Elsevier (Singapore) Pte Ltd. http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/). |
spellingShingle | Original Article Larsen, Britta A. Carr, Lucas J. Dunsiger, Shira Marcus, Bess H. Effect of a moderate-intensity demonstration walk on accuracy of physical activity self-report |
title | Effect of a moderate-intensity demonstration walk on accuracy of physical activity self-report |
title_full | Effect of a moderate-intensity demonstration walk on accuracy of physical activity self-report |
title_fullStr | Effect of a moderate-intensity demonstration walk on accuracy of physical activity self-report |
title_full_unstemmed | Effect of a moderate-intensity demonstration walk on accuracy of physical activity self-report |
title_short | Effect of a moderate-intensity demonstration walk on accuracy of physical activity self-report |
title_sort | effect of a moderate-intensity demonstration walk on accuracy of physical activity self-report |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5812854/ https://www.ncbi.nlm.nih.gov/pubmed/29541123 http://dx.doi.org/10.1016/j.jesf.2016.10.002 |
work_keys_str_mv | AT larsenbrittaa effectofamoderateintensitydemonstrationwalkonaccuracyofphysicalactivityselfreport AT carrlucasj effectofamoderateintensitydemonstrationwalkonaccuracyofphysicalactivityselfreport AT dunsigershira effectofamoderateintensitydemonstrationwalkonaccuracyofphysicalactivityselfreport AT marcusbessh effectofamoderateintensitydemonstrationwalkonaccuracyofphysicalactivityselfreport |