Cargando…

A strain gauge analysis comparing 4‐unit veneered zirconium dioxide implant‐borne fixed dental prosthesis on engaging and non‐engaging abutments before and after torque application

This study quantified the strain development after inserting implant‐borne fixed dental prosthesis (FDP) to various implant–abutment joints. Two bone‐level implants (∅ = 4.1 mm, RC, SLA 10 mm, Ti, Straumann) were inserted in polyurethane models (N = 3) in the area of tooth nos 44 and 47. Four‐unit v...

Descripción completa

Detalles Bibliográficos
Autores principales: Epprecht, Alyssa, Zeltner, Marco, Benic, Goran, Özcan, Mutlu
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5813893/
https://www.ncbi.nlm.nih.gov/pubmed/29744210
http://dx.doi.org/10.1002/cre2.97
_version_ 1783300242085511168
author Epprecht, Alyssa
Zeltner, Marco
Benic, Goran
Özcan, Mutlu
author_facet Epprecht, Alyssa
Zeltner, Marco
Benic, Goran
Özcan, Mutlu
author_sort Epprecht, Alyssa
collection PubMed
description This study quantified the strain development after inserting implant‐borne fixed dental prosthesis (FDP) to various implant–abutment joints. Two bone‐level implants (∅ = 4.1 mm, RC, SLA 10 mm, Ti, Straumann) were inserted in polyurethane models (N = 3) in the area of tooth nos 44 and 47. Four‐unit veneered zirconium dioxide FDPs (n = 2) were fabricated, one of which was fixed on engaging (E; RC Variobase, ∅ = 4.5 mm, H = 3.5 mm) and the other on non‐engaging (NE) abutments (RC Variobase, ∅ = 4.5 mm, H = 5.5 mm). One strain gauge was bonded to the occlusal surface of pontic no. 46 on the FDP and the other two on the polyurethane model. Before (baseline) and after torque (35 Ncm), strain values were recorded three times. Data were analyzed using Kruskal–Wallis and Mann–Whitney U tests (α = 0.05). Mean strain values presented significant increase after torque for both E and NE implant–abutment connection type (baseline: E = 4.33 ± 4.38; NE = 4.85 ± 4.85; torque: E = 196.56 ± 188.02; NE = 275.63 ± 407.7; p < .05). Mean strain values based on implant level presented significant increase after torque for both E and NE implant–abutment connection (baseline: E = 4.94 ± 5.29; NE = 5.78 ± 5.69; torque: E = 253.78 ± 178.14; NE = 347.72 ± 493.06; p < .05). The position of the strain gauge on implants (p = .895), FDP (p = .275), and abutment connection type (p = .873) did not significantly affect the strain values. Strain levels for zirconium dioxide implant‐borne FDPs were not affected by the implant–abutment connection type.
format Online
Article
Text
id pubmed-5813893
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-58138932018-05-09 A strain gauge analysis comparing 4‐unit veneered zirconium dioxide implant‐borne fixed dental prosthesis on engaging and non‐engaging abutments before and after torque application Epprecht, Alyssa Zeltner, Marco Benic, Goran Özcan, Mutlu Clin Exp Dent Res Original Articles This study quantified the strain development after inserting implant‐borne fixed dental prosthesis (FDP) to various implant–abutment joints. Two bone‐level implants (∅ = 4.1 mm, RC, SLA 10 mm, Ti, Straumann) were inserted in polyurethane models (N = 3) in the area of tooth nos 44 and 47. Four‐unit veneered zirconium dioxide FDPs (n = 2) were fabricated, one of which was fixed on engaging (E; RC Variobase, ∅ = 4.5 mm, H = 3.5 mm) and the other on non‐engaging (NE) abutments (RC Variobase, ∅ = 4.5 mm, H = 5.5 mm). One strain gauge was bonded to the occlusal surface of pontic no. 46 on the FDP and the other two on the polyurethane model. Before (baseline) and after torque (35 Ncm), strain values were recorded three times. Data were analyzed using Kruskal–Wallis and Mann–Whitney U tests (α = 0.05). Mean strain values presented significant increase after torque for both E and NE implant–abutment connection type (baseline: E = 4.33 ± 4.38; NE = 4.85 ± 4.85; torque: E = 196.56 ± 188.02; NE = 275.63 ± 407.7; p < .05). Mean strain values based on implant level presented significant increase after torque for both E and NE implant–abutment connection (baseline: E = 4.94 ± 5.29; NE = 5.78 ± 5.69; torque: E = 253.78 ± 178.14; NE = 347.72 ± 493.06; p < .05). The position of the strain gauge on implants (p = .895), FDP (p = .275), and abutment connection type (p = .873) did not significantly affect the strain values. Strain levels for zirconium dioxide implant‐borne FDPs were not affected by the implant–abutment connection type. John Wiley and Sons Inc. 2018-02-15 /pmc/articles/PMC5813893/ /pubmed/29744210 http://dx.doi.org/10.1002/cre2.97 Text en ©2018 The Authors. Clinical and Experimental Dental Research published by John Wiley & Sons Ltd. This is an open access article under the terms of the Creative Commons Attribution (http://creativecommons.org/licenses/by/4.0/) License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Articles
Epprecht, Alyssa
Zeltner, Marco
Benic, Goran
Özcan, Mutlu
A strain gauge analysis comparing 4‐unit veneered zirconium dioxide implant‐borne fixed dental prosthesis on engaging and non‐engaging abutments before and after torque application
title A strain gauge analysis comparing 4‐unit veneered zirconium dioxide implant‐borne fixed dental prosthesis on engaging and non‐engaging abutments before and after torque application
title_full A strain gauge analysis comparing 4‐unit veneered zirconium dioxide implant‐borne fixed dental prosthesis on engaging and non‐engaging abutments before and after torque application
title_fullStr A strain gauge analysis comparing 4‐unit veneered zirconium dioxide implant‐borne fixed dental prosthesis on engaging and non‐engaging abutments before and after torque application
title_full_unstemmed A strain gauge analysis comparing 4‐unit veneered zirconium dioxide implant‐borne fixed dental prosthesis on engaging and non‐engaging abutments before and after torque application
title_short A strain gauge analysis comparing 4‐unit veneered zirconium dioxide implant‐borne fixed dental prosthesis on engaging and non‐engaging abutments before and after torque application
title_sort strain gauge analysis comparing 4‐unit veneered zirconium dioxide implant‐borne fixed dental prosthesis on engaging and non‐engaging abutments before and after torque application
topic Original Articles
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5813893/
https://www.ncbi.nlm.nih.gov/pubmed/29744210
http://dx.doi.org/10.1002/cre2.97
work_keys_str_mv AT epprechtalyssa astraingaugeanalysiscomparing4unitveneeredzirconiumdioxideimplantbornefixeddentalprosthesisonengagingandnonengagingabutmentsbeforeandaftertorqueapplication
AT zeltnermarco astraingaugeanalysiscomparing4unitveneeredzirconiumdioxideimplantbornefixeddentalprosthesisonengagingandnonengagingabutmentsbeforeandaftertorqueapplication
AT benicgoran astraingaugeanalysiscomparing4unitveneeredzirconiumdioxideimplantbornefixeddentalprosthesisonengagingandnonengagingabutmentsbeforeandaftertorqueapplication
AT ozcanmutlu astraingaugeanalysiscomparing4unitveneeredzirconiumdioxideimplantbornefixeddentalprosthesisonengagingandnonengagingabutmentsbeforeandaftertorqueapplication
AT epprechtalyssa straingaugeanalysiscomparing4unitveneeredzirconiumdioxideimplantbornefixeddentalprosthesisonengagingandnonengagingabutmentsbeforeandaftertorqueapplication
AT zeltnermarco straingaugeanalysiscomparing4unitveneeredzirconiumdioxideimplantbornefixeddentalprosthesisonengagingandnonengagingabutmentsbeforeandaftertorqueapplication
AT benicgoran straingaugeanalysiscomparing4unitveneeredzirconiumdioxideimplantbornefixeddentalprosthesisonengagingandnonengagingabutmentsbeforeandaftertorqueapplication
AT ozcanmutlu straingaugeanalysiscomparing4unitveneeredzirconiumdioxideimplantbornefixeddentalprosthesisonengagingandnonengagingabutmentsbeforeandaftertorqueapplication