To reduce the radiation dose given to patients, a tube current modulation (TCM) method has been widely used in diagnostic CT systems. However, the TCM method has not yet been applied to a kV-CBCT system on a LINAC machine. The purpose of this study is to investigate if a TCM method would be desirabl...

Descripción completa

Detalles Bibliográficos
Autores principales: Son, Kihong, Chang, Jieun, Lee, Hoyeon, Kim, Changhwan, Lee, Taewon, Cho, Seungryong, Park, Sohyun, Kim, Jin Sung
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5814001/
https://www.ncbi.nlm.nih.gov/pubmed/29447260
http://dx.doi.org/10.1371/journal.pone.0192933
_version_ 1783300267876286464
author Son, Kihong
Chang, Jieun
Lee, Hoyeon
Kim, Changhwan
Lee, Taewon
Cho, Seungryong
Park, Sohyun
Kim, Jin Sung
author_facet Son, Kihong
Chang, Jieun
Lee, Hoyeon
Kim, Changhwan
Lee, Taewon
Cho, Seungryong
Park, Sohyun
Kim, Jin Sung
author_sort Son, Kihong
collection PubMed
description To reduce the radiation dose given to patients, a tube current modulation (TCM) method has been widely used in diagnostic CT systems. However, the TCM method has not yet been applied to a kV-CBCT system on a LINAC machine. The purpose of this study is to investigate if a TCM method would be desirable in a kV-CBCT system for image-guided radiation therapy (IGRT) or not. We have developed an attenuation–based TCM method using prior knowledge from planning CT images of patients. The TCM method can provide optimized dose reductions without degrading image quality for kV-CBCT imaging. Here, we investigate whether or not our suggested TCM method is desirable to use in kV-CBCT systems to confirm and revise the exact position of a patient for IGRT. Patients go through diagnostic CT scans for RT planning; therefore, using information from prior CT images can enable estimations of the total X-ray attenuation through a patient’s body in a CBCT setting for radiation treatment. Having this planning CT image allows to use the proposed TCM method in RT. The proposed TCM method provides a minimal amount of current for each projection, as well as total current, required to reconstruct the current modulated CBCT image with an image quality similar to that of CBCT. After applying a calculated TCM current for each projection, projection images were acquired and the current modulated CBCT image was reconstructed using a FDK algorithm. To validate the proposed approach, we used a numerical XCAT phantom and a real ATOM phantom and evaluated the performance of the proposed method via visual and quantitative image quality metrics. The organ dose due to imaging radiation was calculated in both cases and compared using the GATE simulation toolkit. As shown in the quantitative evaluation, normalized noise and SSIM values of the TCM were similar to those of conventional CBCT images. In addition, the proposed TCM method yielded comparable image quality to that of conventional CBCT images for both simulations and experimental studies as organ doses were decreased. We have successfully demonstrated the feasibility and dosimetric merit of a prototypical TCM method for kV-CBCT via simulations and experimental study. The results indicate that the proposed TCM method and overall framework can be a viable option for CBCT imaging that utilizes an optimal dose reduction without degrading image quality. Thus, this method reduces the probability for side effects due to radiation exposure.
format Online
Article
Text
id pubmed-5814001
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-58140012018-03-02 Optimal dose reduction algorithm using an attenuation-based tube current modulation method for cone-beam CT imaging Son, Kihong Chang, Jieun Lee, Hoyeon Kim, Changhwan Lee, Taewon Cho, Seungryong Park, Sohyun Kim, Jin Sung PLoS One Research Article To reduce the radiation dose given to patients, a tube current modulation (TCM) method has been widely used in diagnostic CT systems. However, the TCM method has not yet been applied to a kV-CBCT system on a LINAC machine. The purpose of this study is to investigate if a TCM method would be desirable in a kV-CBCT system for image-guided radiation therapy (IGRT) or not. We have developed an attenuation–based TCM method using prior knowledge from planning CT images of patients. The TCM method can provide optimized dose reductions without degrading image quality for kV-CBCT imaging. Here, we investigate whether or not our suggested TCM method is desirable to use in kV-CBCT systems to confirm and revise the exact position of a patient for IGRT. Patients go through diagnostic CT scans for RT planning; therefore, using information from prior CT images can enable estimations of the total X-ray attenuation through a patient’s body in a CBCT setting for radiation treatment. Having this planning CT image allows to use the proposed TCM method in RT. The proposed TCM method provides a minimal amount of current for each projection, as well as total current, required to reconstruct the current modulated CBCT image with an image quality similar to that of CBCT. After applying a calculated TCM current for each projection, projection images were acquired and the current modulated CBCT image was reconstructed using a FDK algorithm. To validate the proposed approach, we used a numerical XCAT phantom and a real ATOM phantom and evaluated the performance of the proposed method via visual and quantitative image quality metrics. The organ dose due to imaging radiation was calculated in both cases and compared using the GATE simulation toolkit. As shown in the quantitative evaluation, normalized noise and SSIM values of the TCM were similar to those of conventional CBCT images. In addition, the proposed TCM method yielded comparable image quality to that of conventional CBCT images for both simulations and experimental studies as organ doses were decreased. We have successfully demonstrated the feasibility and dosimetric merit of a prototypical TCM method for kV-CBCT via simulations and experimental study. The results indicate that the proposed TCM method and overall framework can be a viable option for CBCT imaging that utilizes an optimal dose reduction without degrading image quality. Thus, this method reduces the probability for side effects due to radiation exposure. Public Library of Science 2018-02-15 /pmc/articles/PMC5814001/ /pubmed/29447260 http://dx.doi.org/10.1371/journal.pone.0192933 Text en © 2018 Son et al http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Research Article
Son, Kihong
Chang, Jieun
Lee, Hoyeon
Kim, Changhwan
Lee, Taewon
Cho, Seungryong
Park, Sohyun
Kim, Jin Sung
Optimal dose reduction algorithm using an attenuation-based tube current modulation method for cone-beam CT imaging
title Optimal dose reduction algorithm using an attenuation-based tube current modulation method for cone-beam CT imaging
title_full Optimal dose reduction algorithm using an attenuation-based tube current modulation method for cone-beam CT imaging
title_fullStr Optimal dose reduction algorithm using an attenuation-based tube current modulation method for cone-beam CT imaging
title_full_unstemmed Optimal dose reduction algorithm using an attenuation-based tube current modulation method for cone-beam CT imaging
title_short Optimal dose reduction algorithm using an attenuation-based tube current modulation method for cone-beam CT imaging
title_sort optimal dose reduction algorithm using an attenuation-based tube current modulation method for cone-beam ct imaging
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5814001/
https://www.ncbi.nlm.nih.gov/pubmed/29447260
http://dx.doi.org/10.1371/journal.pone.0192933
work_keys_str_mv AT sonkihong optimaldosereductionalgorithmusinganattenuationbasedtubecurrentmodulationmethodforconebeamctimaging
AT changjieun optimaldosereductionalgorithmusinganattenuationbasedtubecurrentmodulationmethodforconebeamctimaging
AT leehoyeon optimaldosereductionalgorithmusinganattenuationbasedtubecurrentmodulationmethodforconebeamctimaging
AT kimchanghwan optimaldosereductionalgorithmusinganattenuationbasedtubecurrentmodulationmethodforconebeamctimaging
AT leetaewon optimaldosereductionalgorithmusinganattenuationbasedtubecurrentmodulationmethodforconebeamctimaging
AT choseungryong optimaldosereductionalgorithmusinganattenuationbasedtubecurrentmodulationmethodforconebeamctimaging
AT parksohyun optimaldosereductionalgorithmusinganattenuationbasedtubecurrentmodulationmethodforconebeamctimaging
AT kimjinsung optimaldosereductionalgorithmusinganattenuationbasedtubecurrentmodulationmethodforconebeamctimaging