Cargando…

A referenceless Nyquist ghost correction workflow for echo planar imaging of hyperpolarized [1‐(13)C]pyruvate and [1‐(13)C]lactate

Single‐shot echo planar imaging (EPI), which allows an image to be acquired using a single excitation pulse, is used widely for imaging the metabolism of hyperpolarized (13)C‐labelled metabolites in vivo as the technique is rapid and minimizes the depletion of the hyperpolarized signal. However, EPI...

Descripción completa

Detalles Bibliográficos
Autores principales: Wang, Jiazheng, Wright, Alan J., Hesketh, Richard L., Hu, De‐en, Brindle, Kevin M.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5814908/
https://www.ncbi.nlm.nih.gov/pubmed/29215773
http://dx.doi.org/10.1002/nbm.3866
_version_ 1783300426813145088
author Wang, Jiazheng
Wright, Alan J.
Hesketh, Richard L.
Hu, De‐en
Brindle, Kevin M.
author_facet Wang, Jiazheng
Wright, Alan J.
Hesketh, Richard L.
Hu, De‐en
Brindle, Kevin M.
author_sort Wang, Jiazheng
collection PubMed
description Single‐shot echo planar imaging (EPI), which allows an image to be acquired using a single excitation pulse, is used widely for imaging the metabolism of hyperpolarized (13)C‐labelled metabolites in vivo as the technique is rapid and minimizes the depletion of the hyperpolarized signal. However, EPI suffers from Nyquist ghosting, which normally is corrected for by acquiring a reference scan. In a dynamic acquisition of a series of images, this results in the sacrifice of a time point if the reference scan involves a full readout train with no phase encoding. This time penalty is negligible if an integrated navigator echo is used, but at the cost of a lower signal‐to‐noise ratio (SNR) as a result of prolonged T (2)* decay. We describe here a workflow for hyperpolarized (13)C EPI that requires no reference scan. This involves the selection of a ghost‐containing background from a (13)C image of a single metabolite at a single time point, the identification of phase correction coefficients that minimize signal in the selected area, and the application of these coefficients to images acquired at all time points and from all metabolites. The workflow was compared in phantom experiments with phase correction using a (13)C reference scan, and yielded similar results in situations with a regular field of view (FOV), a restricted FOV and where there were multiple signal sources. When compared with alternative phase correction methods, the workflow showed an SNR benefit relative to integrated (13)C reference echoes (>15%) or better ghost removal relative to a (1)H reference scan. The residual ghosting in a slightly de‐shimmed B (0) field was 1.6% using the proposed workflow and 3.8% using a (1)H reference scan. The workflow was implemented with a series of dynamically acquired hyperpolarized [1‐(13)C]pyruvate and [1‐(13)C]lactate images in vivo, resulting in images with no observable ghosting and which were quantitatively similar to images corrected using a (13)C reference scan.
format Online
Article
Text
id pubmed-5814908
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-58149082018-02-27 A referenceless Nyquist ghost correction workflow for echo planar imaging of hyperpolarized [1‐(13)C]pyruvate and [1‐(13)C]lactate Wang, Jiazheng Wright, Alan J. Hesketh, Richard L. Hu, De‐en Brindle, Kevin M. NMR Biomed Research Articles Single‐shot echo planar imaging (EPI), which allows an image to be acquired using a single excitation pulse, is used widely for imaging the metabolism of hyperpolarized (13)C‐labelled metabolites in vivo as the technique is rapid and minimizes the depletion of the hyperpolarized signal. However, EPI suffers from Nyquist ghosting, which normally is corrected for by acquiring a reference scan. In a dynamic acquisition of a series of images, this results in the sacrifice of a time point if the reference scan involves a full readout train with no phase encoding. This time penalty is negligible if an integrated navigator echo is used, but at the cost of a lower signal‐to‐noise ratio (SNR) as a result of prolonged T (2)* decay. We describe here a workflow for hyperpolarized (13)C EPI that requires no reference scan. This involves the selection of a ghost‐containing background from a (13)C image of a single metabolite at a single time point, the identification of phase correction coefficients that minimize signal in the selected area, and the application of these coefficients to images acquired at all time points and from all metabolites. The workflow was compared in phantom experiments with phase correction using a (13)C reference scan, and yielded similar results in situations with a regular field of view (FOV), a restricted FOV and where there were multiple signal sources. When compared with alternative phase correction methods, the workflow showed an SNR benefit relative to integrated (13)C reference echoes (>15%) or better ghost removal relative to a (1)H reference scan. The residual ghosting in a slightly de‐shimmed B (0) field was 1.6% using the proposed workflow and 3.8% using a (1)H reference scan. The workflow was implemented with a series of dynamically acquired hyperpolarized [1‐(13)C]pyruvate and [1‐(13)C]lactate images in vivo, resulting in images with no observable ghosting and which were quantitatively similar to images corrected using a (13)C reference scan. John Wiley and Sons Inc. 2017-12-07 2018-02 /pmc/articles/PMC5814908/ /pubmed/29215773 http://dx.doi.org/10.1002/nbm.3866 Text en © 2017 The Authors. NMR in Biomedicine published by John Wiley & Sons Ltd. This is an open access article under the terms of the Creative Commons Attribution (http://creativecommons.org/licenses/by/4.0/) License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Articles
Wang, Jiazheng
Wright, Alan J.
Hesketh, Richard L.
Hu, De‐en
Brindle, Kevin M.
A referenceless Nyquist ghost correction workflow for echo planar imaging of hyperpolarized [1‐(13)C]pyruvate and [1‐(13)C]lactate
title A referenceless Nyquist ghost correction workflow for echo planar imaging of hyperpolarized [1‐(13)C]pyruvate and [1‐(13)C]lactate
title_full A referenceless Nyquist ghost correction workflow for echo planar imaging of hyperpolarized [1‐(13)C]pyruvate and [1‐(13)C]lactate
title_fullStr A referenceless Nyquist ghost correction workflow for echo planar imaging of hyperpolarized [1‐(13)C]pyruvate and [1‐(13)C]lactate
title_full_unstemmed A referenceless Nyquist ghost correction workflow for echo planar imaging of hyperpolarized [1‐(13)C]pyruvate and [1‐(13)C]lactate
title_short A referenceless Nyquist ghost correction workflow for echo planar imaging of hyperpolarized [1‐(13)C]pyruvate and [1‐(13)C]lactate
title_sort referenceless nyquist ghost correction workflow for echo planar imaging of hyperpolarized [1‐(13)c]pyruvate and [1‐(13)c]lactate
topic Research Articles
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5814908/
https://www.ncbi.nlm.nih.gov/pubmed/29215773
http://dx.doi.org/10.1002/nbm.3866
work_keys_str_mv AT wangjiazheng areferencelessnyquistghostcorrectionworkflowforechoplanarimagingofhyperpolarized113cpyruvateand113clactate
AT wrightalanj areferencelessnyquistghostcorrectionworkflowforechoplanarimagingofhyperpolarized113cpyruvateand113clactate
AT heskethrichardl areferencelessnyquistghostcorrectionworkflowforechoplanarimagingofhyperpolarized113cpyruvateand113clactate
AT hudeen areferencelessnyquistghostcorrectionworkflowforechoplanarimagingofhyperpolarized113cpyruvateand113clactate
AT brindlekevinm areferencelessnyquistghostcorrectionworkflowforechoplanarimagingofhyperpolarized113cpyruvateand113clactate
AT wangjiazheng referencelessnyquistghostcorrectionworkflowforechoplanarimagingofhyperpolarized113cpyruvateand113clactate
AT wrightalanj referencelessnyquistghostcorrectionworkflowforechoplanarimagingofhyperpolarized113cpyruvateand113clactate
AT heskethrichardl referencelessnyquistghostcorrectionworkflowforechoplanarimagingofhyperpolarized113cpyruvateand113clactate
AT hudeen referencelessnyquistghostcorrectionworkflowforechoplanarimagingofhyperpolarized113cpyruvateand113clactate
AT brindlekevinm referencelessnyquistghostcorrectionworkflowforechoplanarimagingofhyperpolarized113cpyruvateand113clactate