Cargando…

The Micromorphological Research of the Internal Structure of Chairside CAD/CAM Materials by the Method of Scanning Impulse Acoustic Microscopy (SIAM)

AIM: The aim of the present work was to compare the elastic properties and internal structure of 4 different CAD/CAM chairside materials, by the method of Scanning Impulse Acoustic Microscopy (SIAM). METHODS: Four chairside CAD/CAM materials with different structures from hybrid ceramic (VITA Enamic...

Descripción completa

Detalles Bibliográficos
Autores principales: Goryainova, Kristina E., Morokov, Egor S., Retinskaja, Marina V., Rusanov, Fedor S., Apresyan, Samvel V., Lebedenko, Igor Yu.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Bentham Open 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5814947/
https://www.ncbi.nlm.nih.gov/pubmed/29492178
http://dx.doi.org/10.2174/1874210601812010125
_version_ 1783300434298929152
author Goryainova, Kristina E.
Morokov, Egor S.
Retinskaja, Marina V.
Rusanov, Fedor S.
Apresyan, Samvel V.
Lebedenko, Igor Yu.
author_facet Goryainova, Kristina E.
Morokov, Egor S.
Retinskaja, Marina V.
Rusanov, Fedor S.
Apresyan, Samvel V.
Lebedenko, Igor Yu.
author_sort Goryainova, Kristina E.
collection PubMed
description AIM: The aim of the present work was to compare the elastic properties and internal structure of 4 different CAD/CAM chairside materials, by the method of Scanning Impulse Acoustic Microscopy (SIAM). METHODS: Four chairside CAD/CAM materials with different structures from hybrid ceramic (VITA Enamic, VITA Zahnfabrik), feldspatic ceramic (VITABlocs Mark II, VITA Zahnfabrik), leucite glass-ceramic (IPS Empress CAD, Ivoclar Vivadent) and PMMA (Telio CAD, Ivoclar Vivadent) were examined by Scanning Impulse Acoustic Microscope (SIAM). RESULTS: The results of micromorphological research of CAD/CAM chairside materials using SIAM method showed differences between the internal structures of these materials. The internal structure of feldspatic and glass-ceramic samples revealed the presence of pores with different sizes, from 10 to 100 microns; the structure of polymer materials rendered some isolated defects, while in the structure of hybrid material, defects were not found. CONCLUSION: Based on the results obtained from the present study, in cases of chairside production of dental crowns, it would be advisable to give preference to the blocks of hybrid ceramics. Such ceramics devoid of quite large porosity, glazing for CAD/CAM crowns made from leucite glass-ceramic and feldspatic ceramic may be an option. For these purposes, commercially available special muffle furnace for clinical and laboratory individualization and glazing of ceramic prostheses were provided. Further studies are needed to confirm the evidence emerging from the present research.
format Online
Article
Text
id pubmed-5814947
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Bentham Open
record_format MEDLINE/PubMed
spelling pubmed-58149472018-02-28 The Micromorphological Research of the Internal Structure of Chairside CAD/CAM Materials by the Method of Scanning Impulse Acoustic Microscopy (SIAM) Goryainova, Kristina E. Morokov, Egor S. Retinskaja, Marina V. Rusanov, Fedor S. Apresyan, Samvel V. Lebedenko, Igor Yu. Open Dent J Dentistry AIM: The aim of the present work was to compare the elastic properties and internal structure of 4 different CAD/CAM chairside materials, by the method of Scanning Impulse Acoustic Microscopy (SIAM). METHODS: Four chairside CAD/CAM materials with different structures from hybrid ceramic (VITA Enamic, VITA Zahnfabrik), feldspatic ceramic (VITABlocs Mark II, VITA Zahnfabrik), leucite glass-ceramic (IPS Empress CAD, Ivoclar Vivadent) and PMMA (Telio CAD, Ivoclar Vivadent) were examined by Scanning Impulse Acoustic Microscope (SIAM). RESULTS: The results of micromorphological research of CAD/CAM chairside materials using SIAM method showed differences between the internal structures of these materials. The internal structure of feldspatic and glass-ceramic samples revealed the presence of pores with different sizes, from 10 to 100 microns; the structure of polymer materials rendered some isolated defects, while in the structure of hybrid material, defects were not found. CONCLUSION: Based on the results obtained from the present study, in cases of chairside production of dental crowns, it would be advisable to give preference to the blocks of hybrid ceramics. Such ceramics devoid of quite large porosity, glazing for CAD/CAM crowns made from leucite glass-ceramic and feldspatic ceramic may be an option. For these purposes, commercially available special muffle furnace for clinical and laboratory individualization and glazing of ceramic prostheses were provided. Further studies are needed to confirm the evidence emerging from the present research. Bentham Open 2018-01-31 /pmc/articles/PMC5814947/ /pubmed/29492178 http://dx.doi.org/10.2174/1874210601812010125 Text en © 2018 Goryainova et al. https://creativecommons.org/licenses/by/4.0/legalcode This is an open access article distributed under the terms of the Creative Commons Attribution 4.0 International Public License (CC-BY 4.0), a copy of which is available at: (https://creativecommons.org/licenses/by/4.0/legalcode). This license permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Dentistry
Goryainova, Kristina E.
Morokov, Egor S.
Retinskaja, Marina V.
Rusanov, Fedor S.
Apresyan, Samvel V.
Lebedenko, Igor Yu.
The Micromorphological Research of the Internal Structure of Chairside CAD/CAM Materials by the Method of Scanning Impulse Acoustic Microscopy (SIAM)
title The Micromorphological Research of the Internal Structure of Chairside CAD/CAM Materials by the Method of Scanning Impulse Acoustic Microscopy (SIAM)
title_full The Micromorphological Research of the Internal Structure of Chairside CAD/CAM Materials by the Method of Scanning Impulse Acoustic Microscopy (SIAM)
title_fullStr The Micromorphological Research of the Internal Structure of Chairside CAD/CAM Materials by the Method of Scanning Impulse Acoustic Microscopy (SIAM)
title_full_unstemmed The Micromorphological Research of the Internal Structure of Chairside CAD/CAM Materials by the Method of Scanning Impulse Acoustic Microscopy (SIAM)
title_short The Micromorphological Research of the Internal Structure of Chairside CAD/CAM Materials by the Method of Scanning Impulse Acoustic Microscopy (SIAM)
title_sort micromorphological research of the internal structure of chairside cad/cam materials by the method of scanning impulse acoustic microscopy (siam)
topic Dentistry
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5814947/
https://www.ncbi.nlm.nih.gov/pubmed/29492178
http://dx.doi.org/10.2174/1874210601812010125
work_keys_str_mv AT goryainovakristinae themicromorphologicalresearchoftheinternalstructureofchairsidecadcammaterialsbythemethodofscanningimpulseacousticmicroscopysiam
AT morokovegors themicromorphologicalresearchoftheinternalstructureofchairsidecadcammaterialsbythemethodofscanningimpulseacousticmicroscopysiam
AT retinskajamarinav themicromorphologicalresearchoftheinternalstructureofchairsidecadcammaterialsbythemethodofscanningimpulseacousticmicroscopysiam
AT rusanovfedors themicromorphologicalresearchoftheinternalstructureofchairsidecadcammaterialsbythemethodofscanningimpulseacousticmicroscopysiam
AT apresyansamvelv themicromorphologicalresearchoftheinternalstructureofchairsidecadcammaterialsbythemethodofscanningimpulseacousticmicroscopysiam
AT lebedenkoigoryu themicromorphologicalresearchoftheinternalstructureofchairsidecadcammaterialsbythemethodofscanningimpulseacousticmicroscopysiam
AT goryainovakristinae micromorphologicalresearchoftheinternalstructureofchairsidecadcammaterialsbythemethodofscanningimpulseacousticmicroscopysiam
AT morokovegors micromorphologicalresearchoftheinternalstructureofchairsidecadcammaterialsbythemethodofscanningimpulseacousticmicroscopysiam
AT retinskajamarinav micromorphologicalresearchoftheinternalstructureofchairsidecadcammaterialsbythemethodofscanningimpulseacousticmicroscopysiam
AT rusanovfedors micromorphologicalresearchoftheinternalstructureofchairsidecadcammaterialsbythemethodofscanningimpulseacousticmicroscopysiam
AT apresyansamvelv micromorphologicalresearchoftheinternalstructureofchairsidecadcammaterialsbythemethodofscanningimpulseacousticmicroscopysiam
AT lebedenkoigoryu micromorphologicalresearchoftheinternalstructureofchairsidecadcammaterialsbythemethodofscanningimpulseacousticmicroscopysiam