Cargando…
Robot-assisted single port radical nephrectomy and cholecystectomy: description and technical aspects
INTRODUCTION: Robot-Assisted Single Site Radical Nephrectomy (RASS-RN) has been reported by surgeons in Europe and United States (1–3). To our best knowledge this video presents the first RASS-RN with concomitant cholecystectomy performed in Latin America. CASE: A 66 year-old renal transplant male d...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Sociedade Brasileira de Urologia
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5815555/ https://www.ncbi.nlm.nih.gov/pubmed/29039889 http://dx.doi.org/10.1590/S1677-5538.IBJU.2016.0560 |
_version_ | 1783300516305960960 |
---|---|
author | Mota, Francisco Hidelbrando Alves Sávio, Luis Felipe Sakata, Rafael Eiji Ivanovic, Renato Fidelis da Silva, Marco Antonio Nunes Maia, Ronaldo Soares Passerotti, Carlo Camargo |
author_facet | Mota, Francisco Hidelbrando Alves Sávio, Luis Felipe Sakata, Rafael Eiji Ivanovic, Renato Fidelis da Silva, Marco Antonio Nunes Maia, Ronaldo Soares Passerotti, Carlo Camargo |
author_sort | Mota, Francisco Hidelbrando Alves |
collection | PubMed |
description | INTRODUCTION: Robot-Assisted Single Site Radical Nephrectomy (RASS-RN) has been reported by surgeons in Europe and United States (1–3). To our best knowledge this video presents the first RASS-RN with concomitant cholecystectomy performed in Latin America. CASE: A 66 year-old renal transplant male due to chronic renal failure presented with an incidental 1.3cm nodule in the upper pole of the right kidney. In addition, symptomatic gallbladder stones were detected. RESULTS: Patient was placed in modified flank position. Multichannel single port device was placed using Hassan's technique through a 3 cm supra-umbilical incision. Standard radical nephrectomy and cholecystectomy were made using an 8.5mm camera, two 5mm robotic arms and an assistant 5mm access. Surgery time and estimated blood loss were 208 minutes and 100mL, respectively. Patient did well and was discharged within less than 48 hours, without complications. Pathology report showed benign renomedullary tumor of interstitial cells and chronic cholecystitis. DISCUSSION: Robotic technology improves ergonomics, gives better precision and enhances ability to approach complex surgeries. Robot-assisted Single Port aims to reduce the morbidity of multiple trocar placements while maintaining the advantages of robotic surgery (2). Limitations include the use of semi-rigid instruments providing less degree of motion and limited space leading to crash between instruments. On the other hand, it is possible to perform complex and concomitant surgeries with just one incision. CONCLUSION: RASS-RN seems to be safe and feasible option for selected cases. Studies should be performed to better understand the results using single port technique in Urology. |
format | Online Article Text |
id | pubmed-5815555 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | Sociedade Brasileira de Urologia |
record_format | MEDLINE/PubMed |
spelling | pubmed-58155552018-02-22 Robot-assisted single port radical nephrectomy and cholecystectomy: description and technical aspects Mota, Francisco Hidelbrando Alves Sávio, Luis Felipe Sakata, Rafael Eiji Ivanovic, Renato Fidelis da Silva, Marco Antonio Nunes Maia, Ronaldo Soares Passerotti, Carlo Camargo Int Braz J Urol Video Section INTRODUCTION: Robot-Assisted Single Site Radical Nephrectomy (RASS-RN) has been reported by surgeons in Europe and United States (1–3). To our best knowledge this video presents the first RASS-RN with concomitant cholecystectomy performed in Latin America. CASE: A 66 year-old renal transplant male due to chronic renal failure presented with an incidental 1.3cm nodule in the upper pole of the right kidney. In addition, symptomatic gallbladder stones were detected. RESULTS: Patient was placed in modified flank position. Multichannel single port device was placed using Hassan's technique through a 3 cm supra-umbilical incision. Standard radical nephrectomy and cholecystectomy were made using an 8.5mm camera, two 5mm robotic arms and an assistant 5mm access. Surgery time and estimated blood loss were 208 minutes and 100mL, respectively. Patient did well and was discharged within less than 48 hours, without complications. Pathology report showed benign renomedullary tumor of interstitial cells and chronic cholecystitis. DISCUSSION: Robotic technology improves ergonomics, gives better precision and enhances ability to approach complex surgeries. Robot-assisted Single Port aims to reduce the morbidity of multiple trocar placements while maintaining the advantages of robotic surgery (2). Limitations include the use of semi-rigid instruments providing less degree of motion and limited space leading to crash between instruments. On the other hand, it is possible to perform complex and concomitant surgeries with just one incision. CONCLUSION: RASS-RN seems to be safe and feasible option for selected cases. Studies should be performed to better understand the results using single port technique in Urology. Sociedade Brasileira de Urologia 2018 /pmc/articles/PMC5815555/ /pubmed/29039889 http://dx.doi.org/10.1590/S1677-5538.IBJU.2016.0560 Text en https://creativecommons.org/licenses/by/4.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Video Section Mota, Francisco Hidelbrando Alves Sávio, Luis Felipe Sakata, Rafael Eiji Ivanovic, Renato Fidelis da Silva, Marco Antonio Nunes Maia, Ronaldo Soares Passerotti, Carlo Camargo Robot-assisted single port radical nephrectomy and cholecystectomy: description and technical aspects |
title | Robot-assisted single port radical nephrectomy and cholecystectomy: description and technical aspects |
title_full | Robot-assisted single port radical nephrectomy and cholecystectomy: description and technical aspects |
title_fullStr | Robot-assisted single port radical nephrectomy and cholecystectomy: description and technical aspects |
title_full_unstemmed | Robot-assisted single port radical nephrectomy and cholecystectomy: description and technical aspects |
title_short | Robot-assisted single port radical nephrectomy and cholecystectomy: description and technical aspects |
title_sort | robot-assisted single port radical nephrectomy and cholecystectomy: description and technical aspects |
topic | Video Section |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5815555/ https://www.ncbi.nlm.nih.gov/pubmed/29039889 http://dx.doi.org/10.1590/S1677-5538.IBJU.2016.0560 |
work_keys_str_mv | AT motafranciscohidelbrandoalves robotassistedsingleportradicalnephrectomyandcholecystectomydescriptionandtechnicalaspects AT savioluisfelipe robotassistedsingleportradicalnephrectomyandcholecystectomydescriptionandtechnicalaspects AT sakatarafaeleiji robotassistedsingleportradicalnephrectomyandcholecystectomydescriptionandtechnicalaspects AT ivanovicrenatofidelis robotassistedsingleportradicalnephrectomyandcholecystectomydescriptionandtechnicalaspects AT dasilvamarcoantonionunes robotassistedsingleportradicalnephrectomyandcholecystectomydescriptionandtechnicalaspects AT maiaronaldosoares robotassistedsingleportradicalnephrectomyandcholecystectomydescriptionandtechnicalaspects AT passerotticarlocamargo robotassistedsingleportradicalnephrectomyandcholecystectomydescriptionandtechnicalaspects |