Cargando…
Experimental modelling of cardiac pressure overload hypertrophy: Modified technique for precise, reproducible, safe and easy aortic arch banding-debanding in mice
Pressure overload left ventricular hypertrophy is a known precursor of heart failure with ominous prognosis. The development of experimental models that reproduce this phenomenon is instrumental for the advancement in our understanding of its pathophysiology. The gold standard of these models is the...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Nature Publishing Group UK
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5816612/ https://www.ncbi.nlm.nih.gov/pubmed/29453394 http://dx.doi.org/10.1038/s41598-018-21548-x |
_version_ | 1783300715735678976 |
---|---|
author | Merino, David Gil, Aritz Gómez, Jenny Ruiz, Luis Llano, Miguel García, Raquel Hurlé, María A. Nistal, J. Francisco |
author_facet | Merino, David Gil, Aritz Gómez, Jenny Ruiz, Luis Llano, Miguel García, Raquel Hurlé, María A. Nistal, J. Francisco |
author_sort | Merino, David |
collection | PubMed |
description | Pressure overload left ventricular hypertrophy is a known precursor of heart failure with ominous prognosis. The development of experimental models that reproduce this phenomenon is instrumental for the advancement in our understanding of its pathophysiology. The gold standard of these models is the controlled constriction of the mid aortic arch in mice according to Rockman’s technique (RT). We developed a modified technique that allows individualized and fully controlled constriction of the aorta, improves efficiency and generates a reproducible stenosis that is technically easy to perform and release. An algorithm calculates, based on the echocardiographic arch diameter, the intended perimeter at the constriction, and a suture is prepared with two knots separated accordingly. The aorta is encircled twice with the suture and the loop is closed with a microclip under both knots. We performed controlled aortic constriction with Rockman’s and the double loop-clip (DLC) techniques in mice. DLC proved superiority in efficiency (mortality and invalid experiments) and more homogeneity of the results (transcoarctational gradients, LV mass, cardiomyocyte hypertrophy, gene expression) than RT. DLC technique optimizes animal use and generates a consistent and customized aortic constriction with homogeneous LV pressure overload morphofunctional, structural, and molecular features. |
format | Online Article Text |
id | pubmed-5816612 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | Nature Publishing Group UK |
record_format | MEDLINE/PubMed |
spelling | pubmed-58166122018-02-21 Experimental modelling of cardiac pressure overload hypertrophy: Modified technique for precise, reproducible, safe and easy aortic arch banding-debanding in mice Merino, David Gil, Aritz Gómez, Jenny Ruiz, Luis Llano, Miguel García, Raquel Hurlé, María A. Nistal, J. Francisco Sci Rep Article Pressure overload left ventricular hypertrophy is a known precursor of heart failure with ominous prognosis. The development of experimental models that reproduce this phenomenon is instrumental for the advancement in our understanding of its pathophysiology. The gold standard of these models is the controlled constriction of the mid aortic arch in mice according to Rockman’s technique (RT). We developed a modified technique that allows individualized and fully controlled constriction of the aorta, improves efficiency and generates a reproducible stenosis that is technically easy to perform and release. An algorithm calculates, based on the echocardiographic arch diameter, the intended perimeter at the constriction, and a suture is prepared with two knots separated accordingly. The aorta is encircled twice with the suture and the loop is closed with a microclip under both knots. We performed controlled aortic constriction with Rockman’s and the double loop-clip (DLC) techniques in mice. DLC proved superiority in efficiency (mortality and invalid experiments) and more homogeneity of the results (transcoarctational gradients, LV mass, cardiomyocyte hypertrophy, gene expression) than RT. DLC technique optimizes animal use and generates a consistent and customized aortic constriction with homogeneous LV pressure overload morphofunctional, structural, and molecular features. Nature Publishing Group UK 2018-02-16 /pmc/articles/PMC5816612/ /pubmed/29453394 http://dx.doi.org/10.1038/s41598-018-21548-x Text en © The Author(s) 2018 Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons license and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/. |
spellingShingle | Article Merino, David Gil, Aritz Gómez, Jenny Ruiz, Luis Llano, Miguel García, Raquel Hurlé, María A. Nistal, J. Francisco Experimental modelling of cardiac pressure overload hypertrophy: Modified technique for precise, reproducible, safe and easy aortic arch banding-debanding in mice |
title | Experimental modelling of cardiac pressure overload hypertrophy: Modified technique for precise, reproducible, safe and easy aortic arch banding-debanding in mice |
title_full | Experimental modelling of cardiac pressure overload hypertrophy: Modified technique for precise, reproducible, safe and easy aortic arch banding-debanding in mice |
title_fullStr | Experimental modelling of cardiac pressure overload hypertrophy: Modified technique for precise, reproducible, safe and easy aortic arch banding-debanding in mice |
title_full_unstemmed | Experimental modelling of cardiac pressure overload hypertrophy: Modified technique for precise, reproducible, safe and easy aortic arch banding-debanding in mice |
title_short | Experimental modelling of cardiac pressure overload hypertrophy: Modified technique for precise, reproducible, safe and easy aortic arch banding-debanding in mice |
title_sort | experimental modelling of cardiac pressure overload hypertrophy: modified technique for precise, reproducible, safe and easy aortic arch banding-debanding in mice |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5816612/ https://www.ncbi.nlm.nih.gov/pubmed/29453394 http://dx.doi.org/10.1038/s41598-018-21548-x |
work_keys_str_mv | AT merinodavid experimentalmodellingofcardiacpressureoverloadhypertrophymodifiedtechniqueforprecisereproduciblesafeandeasyaorticarchbandingdebandinginmice AT gilaritz experimentalmodellingofcardiacpressureoverloadhypertrophymodifiedtechniqueforprecisereproduciblesafeandeasyaorticarchbandingdebandinginmice AT gomezjenny experimentalmodellingofcardiacpressureoverloadhypertrophymodifiedtechniqueforprecisereproduciblesafeandeasyaorticarchbandingdebandinginmice AT ruizluis experimentalmodellingofcardiacpressureoverloadhypertrophymodifiedtechniqueforprecisereproduciblesafeandeasyaorticarchbandingdebandinginmice AT llanomiguel experimentalmodellingofcardiacpressureoverloadhypertrophymodifiedtechniqueforprecisereproduciblesafeandeasyaorticarchbandingdebandinginmice AT garciaraquel experimentalmodellingofcardiacpressureoverloadhypertrophymodifiedtechniqueforprecisereproduciblesafeandeasyaorticarchbandingdebandinginmice AT hurlemariaa experimentalmodellingofcardiacpressureoverloadhypertrophymodifiedtechniqueforprecisereproduciblesafeandeasyaorticarchbandingdebandinginmice AT nistaljfrancisco experimentalmodellingofcardiacpressureoverloadhypertrophymodifiedtechniqueforprecisereproduciblesafeandeasyaorticarchbandingdebandinginmice |