Cargando…
Modified Descemet's Stripping Automated Endothelial Keratoplasty: The Use of Ophthalmic Viscoelastic Devices in Hypotonic Eyes That Had Undergone Glaucoma Filtering Surgeries
PURPOSE: Descemet's stripping automated endothelial keratoplasty (DSAEK) is more difficult in hypotonic eyes with filtering bleb, due to the difficulties in elevating the intraocular pressure (IOP). We report a new method that uses ophthalmic viscoelastic devices (OVDs) to achieve good graft ad...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Hindawi
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5816860/ https://www.ncbi.nlm.nih.gov/pubmed/29487754 http://dx.doi.org/10.1155/2018/9387810 |
_version_ | 1783300764879290368 |
---|---|
author | Oyakawa, Itaru Hayashi, Takahiko Shimizu, Toshiki Kato, Naoko |
author_facet | Oyakawa, Itaru Hayashi, Takahiko Shimizu, Toshiki Kato, Naoko |
author_sort | Oyakawa, Itaru |
collection | PubMed |
description | PURPOSE: Descemet's stripping automated endothelial keratoplasty (DSAEK) is more difficult in hypotonic eyes with filtering bleb, due to the difficulties in elevating the intraocular pressure (IOP). We report a new method that uses ophthalmic viscoelastic devices (OVDs) to achieve good graft adhesion. CASE PRESENTATION: We performed modified DSAEK surgery on 2 eyes of 2 patients, who had previously undergone a trabeculectomy. Both eyes had functioning filtering blebs; the IOP was lower than 10 mmHg without medication. After the graft was inserted into the anterior chamber, the conjunctiva was penetrated, apart from the bleb, using a 30 G needle, and Healon V® was injected into the bleb until the encapsulated space was filled completely. Air was subsequently injected into the anterior chamber to promote the graft attachment to the back surface of the cornea. The IOP was elevated above 40 mmHg in both eyes 1 h after surgery and then decreased to less than 30 mmHg over the subsequent 3 h period. The implanted graft showed good adhesion and no dislocation. CONCLUSIONS: Our novel DSAEK procedure that adds one step of OVD injection into the filtering bleb may be useful for hypotonic eyes that had undergone filtering surgeries. |
format | Online Article Text |
id | pubmed-5816860 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | Hindawi |
record_format | MEDLINE/PubMed |
spelling | pubmed-58168602018-02-27 Modified Descemet's Stripping Automated Endothelial Keratoplasty: The Use of Ophthalmic Viscoelastic Devices in Hypotonic Eyes That Had Undergone Glaucoma Filtering Surgeries Oyakawa, Itaru Hayashi, Takahiko Shimizu, Toshiki Kato, Naoko Case Rep Ophthalmol Med Case Report PURPOSE: Descemet's stripping automated endothelial keratoplasty (DSAEK) is more difficult in hypotonic eyes with filtering bleb, due to the difficulties in elevating the intraocular pressure (IOP). We report a new method that uses ophthalmic viscoelastic devices (OVDs) to achieve good graft adhesion. CASE PRESENTATION: We performed modified DSAEK surgery on 2 eyes of 2 patients, who had previously undergone a trabeculectomy. Both eyes had functioning filtering blebs; the IOP was lower than 10 mmHg without medication. After the graft was inserted into the anterior chamber, the conjunctiva was penetrated, apart from the bleb, using a 30 G needle, and Healon V® was injected into the bleb until the encapsulated space was filled completely. Air was subsequently injected into the anterior chamber to promote the graft attachment to the back surface of the cornea. The IOP was elevated above 40 mmHg in both eyes 1 h after surgery and then decreased to less than 30 mmHg over the subsequent 3 h period. The implanted graft showed good adhesion and no dislocation. CONCLUSIONS: Our novel DSAEK procedure that adds one step of OVD injection into the filtering bleb may be useful for hypotonic eyes that had undergone filtering surgeries. Hindawi 2018-02-01 /pmc/articles/PMC5816860/ /pubmed/29487754 http://dx.doi.org/10.1155/2018/9387810 Text en Copyright © 2018 Itaru Oyakawa et al. https://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Case Report Oyakawa, Itaru Hayashi, Takahiko Shimizu, Toshiki Kato, Naoko Modified Descemet's Stripping Automated Endothelial Keratoplasty: The Use of Ophthalmic Viscoelastic Devices in Hypotonic Eyes That Had Undergone Glaucoma Filtering Surgeries |
title | Modified Descemet's Stripping Automated Endothelial Keratoplasty: The Use of Ophthalmic Viscoelastic Devices in Hypotonic Eyes That Had Undergone Glaucoma Filtering Surgeries |
title_full | Modified Descemet's Stripping Automated Endothelial Keratoplasty: The Use of Ophthalmic Viscoelastic Devices in Hypotonic Eyes That Had Undergone Glaucoma Filtering Surgeries |
title_fullStr | Modified Descemet's Stripping Automated Endothelial Keratoplasty: The Use of Ophthalmic Viscoelastic Devices in Hypotonic Eyes That Had Undergone Glaucoma Filtering Surgeries |
title_full_unstemmed | Modified Descemet's Stripping Automated Endothelial Keratoplasty: The Use of Ophthalmic Viscoelastic Devices in Hypotonic Eyes That Had Undergone Glaucoma Filtering Surgeries |
title_short | Modified Descemet's Stripping Automated Endothelial Keratoplasty: The Use of Ophthalmic Viscoelastic Devices in Hypotonic Eyes That Had Undergone Glaucoma Filtering Surgeries |
title_sort | modified descemet's stripping automated endothelial keratoplasty: the use of ophthalmic viscoelastic devices in hypotonic eyes that had undergone glaucoma filtering surgeries |
topic | Case Report |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5816860/ https://www.ncbi.nlm.nih.gov/pubmed/29487754 http://dx.doi.org/10.1155/2018/9387810 |
work_keys_str_mv | AT oyakawaitaru modifieddescemetsstrippingautomatedendothelialkeratoplastytheuseofophthalmicviscoelasticdevicesinhypotoniceyesthathadundergoneglaucomafilteringsurgeries AT hayashitakahiko modifieddescemetsstrippingautomatedendothelialkeratoplastytheuseofophthalmicviscoelasticdevicesinhypotoniceyesthathadundergoneglaucomafilteringsurgeries AT shimizutoshiki modifieddescemetsstrippingautomatedendothelialkeratoplastytheuseofophthalmicviscoelasticdevicesinhypotoniceyesthathadundergoneglaucomafilteringsurgeries AT katonaoko modifieddescemetsstrippingautomatedendothelialkeratoplastytheuseofophthalmicviscoelasticdevicesinhypotoniceyesthathadundergoneglaucomafilteringsurgeries |