Cargando…
Influence of orthodontic appliance-derived artifacts on 3-T MRI movies
BACKGROUND: Magnetic resonance imaging (MRI) has been used to study configurations of speech organs in the resting state. However, MRI is sensitive to metals, and numerous types of metallic appliances, most of which have a large magnetic susceptibility, are used in orthodontic treatment and may caus...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer Berlin Heidelberg
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5817053/ https://www.ncbi.nlm.nih.gov/pubmed/29457192 http://dx.doi.org/10.1186/s40510-018-0204-6 |
_version_ | 1783300796684697600 |
---|---|
author | Ozawa, Erika Honda, Ei-ichi Parakonthun, Kulthida Nunthayanon Ohmori, Hiroko Shimazaki, Kazuo Kurabayashi, Tohru Ono, Takashi |
author_facet | Ozawa, Erika Honda, Ei-ichi Parakonthun, Kulthida Nunthayanon Ohmori, Hiroko Shimazaki, Kazuo Kurabayashi, Tohru Ono, Takashi |
author_sort | Ozawa, Erika |
collection | PubMed |
description | BACKGROUND: Magnetic resonance imaging (MRI) has been used to study configurations of speech organs in the resting state. However, MRI is sensitive to metals, and numerous types of metallic appliances, most of which have a large magnetic susceptibility, are used in orthodontic treatment and may cause severe artifacts on MRI. We have developed techniques for obtaining MRI movies of the oral region, to evaluate articulatory changes, especially movement of the tongue, palate, and teeth, pre- and post-orthodontic/orthognathic treatment. We evaluated the influence of artifacts caused by orthodontic appliances, including fixed retainers, metal brackets, and wires, on measurements in 3-T MRI movies. METHODS: Sixteen healthy young adults (nine males, seven females; average age, 27 years) with normal occlusion were recruited. Four types of customized maxillary and mandibular plates were prepared by incorporating one of the following into the plate: (a) nothing, (b) a fixed canine-to-canine retainer, (c) metal brackets for the anterior and molar teeth, or (d) clear brackets for the anterior teeth and metal brackets for molars. A 3-T MRI movie, in segmented cine mode, was generated for each plate condition while participants pronounced a vowel-consonant-vowel syllable (/asa/). The size of the artifact due to the metallic brackets was measured. The face size and orthodontically important anatomical structures, such as the velum, the hard palate, and the laryngeal ventricle, were also measured. RESULTS: A large artifact was observed over the entire oral region around orthodontic appliances, altering regional visibility. The velopharyngeal height was measured as significantly longer in the presence of metal brackets. The maximum artifact size due to a metallic bracket was > 8 cm. Our results show that even if it is possible to obtain the measurements of palate length, nasion to sella, and nasion to basion in individuals wearing metal brackets for molars, the measurements might be affected due to the presence of artifacts. CONCLUSIONS: Orthodontic appliances, including metallic materials, sometimes produce significant measurement error in speech evaluation using MRI movies, which often become invisible or distorted by metallic orthodontic appliances. When the distorted image is measured, caution should be exercised, as the measurement may be affected. Based on the study, it is concluded that orthodontists should not necessarily remove all metallic appliances before MRI examination because the influence varies among the appliances and should also know that a significant measurement error in speech evaluation using MRI movie may occur by image distortion caused by metallic artifacts. |
format | Online Article Text |
id | pubmed-5817053 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | Springer Berlin Heidelberg |
record_format | MEDLINE/PubMed |
spelling | pubmed-58170532018-02-27 Influence of orthodontic appliance-derived artifacts on 3-T MRI movies Ozawa, Erika Honda, Ei-ichi Parakonthun, Kulthida Nunthayanon Ohmori, Hiroko Shimazaki, Kazuo Kurabayashi, Tohru Ono, Takashi Prog Orthod Research BACKGROUND: Magnetic resonance imaging (MRI) has been used to study configurations of speech organs in the resting state. However, MRI is sensitive to metals, and numerous types of metallic appliances, most of which have a large magnetic susceptibility, are used in orthodontic treatment and may cause severe artifacts on MRI. We have developed techniques for obtaining MRI movies of the oral region, to evaluate articulatory changes, especially movement of the tongue, palate, and teeth, pre- and post-orthodontic/orthognathic treatment. We evaluated the influence of artifacts caused by orthodontic appliances, including fixed retainers, metal brackets, and wires, on measurements in 3-T MRI movies. METHODS: Sixteen healthy young adults (nine males, seven females; average age, 27 years) with normal occlusion were recruited. Four types of customized maxillary and mandibular plates were prepared by incorporating one of the following into the plate: (a) nothing, (b) a fixed canine-to-canine retainer, (c) metal brackets for the anterior and molar teeth, or (d) clear brackets for the anterior teeth and metal brackets for molars. A 3-T MRI movie, in segmented cine mode, was generated for each plate condition while participants pronounced a vowel-consonant-vowel syllable (/asa/). The size of the artifact due to the metallic brackets was measured. The face size and orthodontically important anatomical structures, such as the velum, the hard palate, and the laryngeal ventricle, were also measured. RESULTS: A large artifact was observed over the entire oral region around orthodontic appliances, altering regional visibility. The velopharyngeal height was measured as significantly longer in the presence of metal brackets. The maximum artifact size due to a metallic bracket was > 8 cm. Our results show that even if it is possible to obtain the measurements of palate length, nasion to sella, and nasion to basion in individuals wearing metal brackets for molars, the measurements might be affected due to the presence of artifacts. CONCLUSIONS: Orthodontic appliances, including metallic materials, sometimes produce significant measurement error in speech evaluation using MRI movies, which often become invisible or distorted by metallic orthodontic appliances. When the distorted image is measured, caution should be exercised, as the measurement may be affected. Based on the study, it is concluded that orthodontists should not necessarily remove all metallic appliances before MRI examination because the influence varies among the appliances and should also know that a significant measurement error in speech evaluation using MRI movie may occur by image distortion caused by metallic artifacts. Springer Berlin Heidelberg 2018-02-19 /pmc/articles/PMC5817053/ /pubmed/29457192 http://dx.doi.org/10.1186/s40510-018-0204-6 Text en © The Author(s). 2018 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. |
spellingShingle | Research Ozawa, Erika Honda, Ei-ichi Parakonthun, Kulthida Nunthayanon Ohmori, Hiroko Shimazaki, Kazuo Kurabayashi, Tohru Ono, Takashi Influence of orthodontic appliance-derived artifacts on 3-T MRI movies |
title | Influence of orthodontic appliance-derived artifacts on 3-T MRI movies |
title_full | Influence of orthodontic appliance-derived artifacts on 3-T MRI movies |
title_fullStr | Influence of orthodontic appliance-derived artifacts on 3-T MRI movies |
title_full_unstemmed | Influence of orthodontic appliance-derived artifacts on 3-T MRI movies |
title_short | Influence of orthodontic appliance-derived artifacts on 3-T MRI movies |
title_sort | influence of orthodontic appliance-derived artifacts on 3-t mri movies |
topic | Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5817053/ https://www.ncbi.nlm.nih.gov/pubmed/29457192 http://dx.doi.org/10.1186/s40510-018-0204-6 |
work_keys_str_mv | AT ozawaerika influenceoforthodonticappliancederivedartifactson3tmrimovies AT hondaeiichi influenceoforthodonticappliancederivedartifactson3tmrimovies AT parakonthunkulthidanunthayanon influenceoforthodonticappliancederivedartifactson3tmrimovies AT ohmorihiroko influenceoforthodonticappliancederivedartifactson3tmrimovies AT shimazakikazuo influenceoforthodonticappliancederivedartifactson3tmrimovies AT kurabayashitohru influenceoforthodonticappliancederivedartifactson3tmrimovies AT onotakashi influenceoforthodonticappliancederivedartifactson3tmrimovies |