Cargando…

Change of Safe Needling Depth at Acupoint GB21 according to Posture and Breathing

Acupoint GB21 (Jianjing) is used for treating back and shoulder pain but is associated with a risk of pneumothorax. We aimed to determine the SND (safe needling depth) at GB21 according to posture and breathing in real time. Ultrasonographic images of GB21 during normal breathing, inspiration, and e...

Descripción completa

Detalles Bibliográficos
Autores principales: Chu, Hongmin, Kim, Jaehyun, Ha, Wonbae, Cho, Eunbyul, Kang, Geon, Park, Seongjun, Jang, Jongwon, Yang, Seung Bum, Kang, Yeonseok, Lee, Sanghun, Kim, Jae-Hyo
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5817322/
https://www.ncbi.nlm.nih.gov/pubmed/29507586
http://dx.doi.org/10.1155/2018/2308102
_version_ 1783300854118350848
author Chu, Hongmin
Kim, Jaehyun
Ha, Wonbae
Cho, Eunbyul
Kang, Geon
Park, Seongjun
Jang, Jongwon
Yang, Seung Bum
Kang, Yeonseok
Lee, Sanghun
Kim, Jae-Hyo
author_facet Chu, Hongmin
Kim, Jaehyun
Ha, Wonbae
Cho, Eunbyul
Kang, Geon
Park, Seongjun
Jang, Jongwon
Yang, Seung Bum
Kang, Yeonseok
Lee, Sanghun
Kim, Jae-Hyo
author_sort Chu, Hongmin
collection PubMed
description Acupoint GB21 (Jianjing) is used for treating back and shoulder pain but is associated with a risk of pneumothorax. We aimed to determine the SND (safe needling depth) at GB21 according to posture and breathing in real time. Ultrasonographic images of GB21 during normal breathing, inspiration, and expiration in a SP (sitting position) were acquired for 52 healthy volunteers. Images were also acquired during normal respiration in the PP (prone position) with arms raised and lowered. The average SND was greater for men than for women (p < 0.05). Analysis of variance revealed that the SND was greater for the PP than for the SP (p = 0.01 and p < 0.05, resp.). Although the SND tended to change according to posture, the average depth tended to deviate widely in some subjects. During breathing, the differences between inspiration and expiration were less than 1 mm in most subjects, but some showed differences more than 4.5 mm. The SND at GB21 was greater in overweight subjects and significantly greater in the PP and during maximal expiration. However, intragroup differences were greater than the intergroup differences. Therefore, it is dangerous to simply apply needling depth on a gender or BMI basis. The practitioner would adjust the SND by examining the individual anatomical structures.
format Online
Article
Text
id pubmed-5817322
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Hindawi
record_format MEDLINE/PubMed
spelling pubmed-58173222018-03-05 Change of Safe Needling Depth at Acupoint GB21 according to Posture and Breathing Chu, Hongmin Kim, Jaehyun Ha, Wonbae Cho, Eunbyul Kang, Geon Park, Seongjun Jang, Jongwon Yang, Seung Bum Kang, Yeonseok Lee, Sanghun Kim, Jae-Hyo Evid Based Complement Alternat Med Research Article Acupoint GB21 (Jianjing) is used for treating back and shoulder pain but is associated with a risk of pneumothorax. We aimed to determine the SND (safe needling depth) at GB21 according to posture and breathing in real time. Ultrasonographic images of GB21 during normal breathing, inspiration, and expiration in a SP (sitting position) were acquired for 52 healthy volunteers. Images were also acquired during normal respiration in the PP (prone position) with arms raised and lowered. The average SND was greater for men than for women (p < 0.05). Analysis of variance revealed that the SND was greater for the PP than for the SP (p = 0.01 and p < 0.05, resp.). Although the SND tended to change according to posture, the average depth tended to deviate widely in some subjects. During breathing, the differences between inspiration and expiration were less than 1 mm in most subjects, but some showed differences more than 4.5 mm. The SND at GB21 was greater in overweight subjects and significantly greater in the PP and during maximal expiration. However, intragroup differences were greater than the intergroup differences. Therefore, it is dangerous to simply apply needling depth on a gender or BMI basis. The practitioner would adjust the SND by examining the individual anatomical structures. Hindawi 2018-01-08 /pmc/articles/PMC5817322/ /pubmed/29507586 http://dx.doi.org/10.1155/2018/2308102 Text en Copyright © 2018 Hongmin Chu et al. https://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Chu, Hongmin
Kim, Jaehyun
Ha, Wonbae
Cho, Eunbyul
Kang, Geon
Park, Seongjun
Jang, Jongwon
Yang, Seung Bum
Kang, Yeonseok
Lee, Sanghun
Kim, Jae-Hyo
Change of Safe Needling Depth at Acupoint GB21 according to Posture and Breathing
title Change of Safe Needling Depth at Acupoint GB21 according to Posture and Breathing
title_full Change of Safe Needling Depth at Acupoint GB21 according to Posture and Breathing
title_fullStr Change of Safe Needling Depth at Acupoint GB21 according to Posture and Breathing
title_full_unstemmed Change of Safe Needling Depth at Acupoint GB21 according to Posture and Breathing
title_short Change of Safe Needling Depth at Acupoint GB21 according to Posture and Breathing
title_sort change of safe needling depth at acupoint gb21 according to posture and breathing
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5817322/
https://www.ncbi.nlm.nih.gov/pubmed/29507586
http://dx.doi.org/10.1155/2018/2308102
work_keys_str_mv AT chuhongmin changeofsafeneedlingdepthatacupointgb21accordingtopostureandbreathing
AT kimjaehyun changeofsafeneedlingdepthatacupointgb21accordingtopostureandbreathing
AT hawonbae changeofsafeneedlingdepthatacupointgb21accordingtopostureandbreathing
AT choeunbyul changeofsafeneedlingdepthatacupointgb21accordingtopostureandbreathing
AT kanggeon changeofsafeneedlingdepthatacupointgb21accordingtopostureandbreathing
AT parkseongjun changeofsafeneedlingdepthatacupointgb21accordingtopostureandbreathing
AT jangjongwon changeofsafeneedlingdepthatacupointgb21accordingtopostureandbreathing
AT yangseungbum changeofsafeneedlingdepthatacupointgb21accordingtopostureandbreathing
AT kangyeonseok changeofsafeneedlingdepthatacupointgb21accordingtopostureandbreathing
AT leesanghun changeofsafeneedlingdepthatacupointgb21accordingtopostureandbreathing
AT kimjaehyo changeofsafeneedlingdepthatacupointgb21accordingtopostureandbreathing