Bias due to Preanalytical Dilution of Rodent Serum for Biochemical Analysis on the Siemens Dimension Xpand Plus

Clinical pathology testing of rodents is often challenging due to insufficient sample volume. One solution in clinical veterinary and exploratory research environments is dilution of samples prior to analysis. However, published information on the impact of preanalytical sample dilution on rodent bi...

Descripción completa

Detalles Bibliográficos
Autores principales: Johns, Jennifer L., Moorhead, Kaitlin A., Hu, Jing, Moorhead, Roberta C.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5818404/
https://www.ncbi.nlm.nih.gov/pubmed/29497614
http://dx.doi.org/10.3389/fvets.2018.00003
_version_ 1783301010509266944
author Johns, Jennifer L.
Moorhead, Kaitlin A.
Hu, Jing
Moorhead, Roberta C.
author_facet Johns, Jennifer L.
Moorhead, Kaitlin A.
Hu, Jing
Moorhead, Roberta C.
author_sort Johns, Jennifer L.
collection PubMed
description Clinical pathology testing of rodents is often challenging due to insufficient sample volume. One solution in clinical veterinary and exploratory research environments is dilution of samples prior to analysis. However, published information on the impact of preanalytical sample dilution on rodent biochemical data is incomplete. The objective of this study was to evaluate the effects of preanalytical sample dilution on biochemical analysis of mouse and rat serum samples utilizing the Siemens Dimension Xpand Plus. Rats were obtained from end of study research projects. Mice were obtained from sentinel testing programs. For both, whole blood was collected via terminal cardiocentesis into empty tubes and serum was harvested. Biochemical parameters were measured on fresh and thawed frozen samples run straight and at dilution factors 2–10. Dilutions were performed manually, utilizing either ultrapure water or enzyme diluent per manufacturer recommendations. All diluted samples were generated directly from the undiluted sample. Preanalytical dilution caused clinically unacceptable bias in most analytes at dilution factors four and above. Dilution-induced bias in total calcium, creatinine, total bilirubin, and uric acid was considered unacceptable with any degree of dilution, based on the more conservative of two definitions of acceptability. Dilution often caused electrolyte values to fall below assay range precluding evaluation of bias. Dilution-induced bias occurred in most biochemical parameters to varying degrees and may render dilution unacceptable in the exploratory research and clinical veterinary environments. Additionally, differences between results obtained at different dilution factors may confound statistical comparisons in research settings. Comparison of data obtained at a single dilution factor is highly recommended.
format Online
Article
Text
id pubmed-5818404
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Frontiers Media S.A.
record_format MEDLINE/PubMed
spelling pubmed-58184042018-03-01 Bias due to Preanalytical Dilution of Rodent Serum for Biochemical Analysis on the Siemens Dimension Xpand Plus Johns, Jennifer L. Moorhead, Kaitlin A. Hu, Jing Moorhead, Roberta C. Front Vet Sci Veterinary Science Clinical pathology testing of rodents is often challenging due to insufficient sample volume. One solution in clinical veterinary and exploratory research environments is dilution of samples prior to analysis. However, published information on the impact of preanalytical sample dilution on rodent biochemical data is incomplete. The objective of this study was to evaluate the effects of preanalytical sample dilution on biochemical analysis of mouse and rat serum samples utilizing the Siemens Dimension Xpand Plus. Rats were obtained from end of study research projects. Mice were obtained from sentinel testing programs. For both, whole blood was collected via terminal cardiocentesis into empty tubes and serum was harvested. Biochemical parameters were measured on fresh and thawed frozen samples run straight and at dilution factors 2–10. Dilutions were performed manually, utilizing either ultrapure water or enzyme diluent per manufacturer recommendations. All diluted samples were generated directly from the undiluted sample. Preanalytical dilution caused clinically unacceptable bias in most analytes at dilution factors four and above. Dilution-induced bias in total calcium, creatinine, total bilirubin, and uric acid was considered unacceptable with any degree of dilution, based on the more conservative of two definitions of acceptability. Dilution often caused electrolyte values to fall below assay range precluding evaluation of bias. Dilution-induced bias occurred in most biochemical parameters to varying degrees and may render dilution unacceptable in the exploratory research and clinical veterinary environments. Additionally, differences between results obtained at different dilution factors may confound statistical comparisons in research settings. Comparison of data obtained at a single dilution factor is highly recommended. Frontiers Media S.A. 2018-02-15 /pmc/articles/PMC5818404/ /pubmed/29497614 http://dx.doi.org/10.3389/fvets.2018.00003 Text en Copyright © 2018 Johns, Moorhead, Hu and Moorhead. http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
spellingShingle Veterinary Science
Johns, Jennifer L.
Moorhead, Kaitlin A.
Hu, Jing
Moorhead, Roberta C.
Bias due to Preanalytical Dilution of Rodent Serum for Biochemical Analysis on the Siemens Dimension Xpand Plus
title Bias due to Preanalytical Dilution of Rodent Serum for Biochemical Analysis on the Siemens Dimension Xpand Plus
title_full Bias due to Preanalytical Dilution of Rodent Serum for Biochemical Analysis on the Siemens Dimension Xpand Plus
title_fullStr Bias due to Preanalytical Dilution of Rodent Serum for Biochemical Analysis on the Siemens Dimension Xpand Plus
title_full_unstemmed Bias due to Preanalytical Dilution of Rodent Serum for Biochemical Analysis on the Siemens Dimension Xpand Plus
title_short Bias due to Preanalytical Dilution of Rodent Serum for Biochemical Analysis on the Siemens Dimension Xpand Plus
title_sort bias due to preanalytical dilution of rodent serum for biochemical analysis on the siemens dimension xpand plus
topic Veterinary Science
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5818404/
https://www.ncbi.nlm.nih.gov/pubmed/29497614
http://dx.doi.org/10.3389/fvets.2018.00003
work_keys_str_mv AT johnsjenniferl biasduetopreanalyticaldilutionofrodentserumforbiochemicalanalysisonthesiemensdimensionxpandplus
AT moorheadkaitlina biasduetopreanalyticaldilutionofrodentserumforbiochemicalanalysisonthesiemensdimensionxpandplus
AT hujing biasduetopreanalyticaldilutionofrodentserumforbiochemicalanalysisonthesiemensdimensionxpandplus
AT moorheadrobertac biasduetopreanalyticaldilutionofrodentserumforbiochemicalanalysisonthesiemensdimensionxpandplus