Cargando…

Cardiovascular cine imaging and flow evaluation using Fast Interrupted Steady-State (FISS) magnetic resonance

BACKGROUND: Existing cine imaging techniques rely on balanced steady-state free precession (bSSFP) or spoiled gradient-echo readouts, each of which has limitations. For instance, with bSSFP, artifacts occur from rapid through-plane flow and off-resonance effects. We hypothesized that a prototype cin...

Descripción completa

Detalles Bibliográficos
Autores principales: Edelman, Robert R., Serhal, Ali, Pursnani, Amit, Pang, Jianing, Koktzoglou, Ioannis
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5819298/
https://www.ncbi.nlm.nih.gov/pubmed/29458384
http://dx.doi.org/10.1186/s12968-018-0433-3
_version_ 1783301187658842112
author Edelman, Robert R.
Serhal, Ali
Pursnani, Amit
Pang, Jianing
Koktzoglou, Ioannis
author_facet Edelman, Robert R.
Serhal, Ali
Pursnani, Amit
Pang, Jianing
Koktzoglou, Ioannis
author_sort Edelman, Robert R.
collection PubMed
description BACKGROUND: Existing cine imaging techniques rely on balanced steady-state free precession (bSSFP) or spoiled gradient-echo readouts, each of which has limitations. For instance, with bSSFP, artifacts occur from rapid through-plane flow and off-resonance effects. We hypothesized that a prototype cine technique, radial fast interrupted steady-state (FISS), could overcome these limitations. The technique was compared with standard cine bSSFP for cardiac function, coronary artery conspicuity, and aortic valve morphology. Given its advantageous properties, we further hypothesized that the cine FISS technique, in combination with arterial spin labeling (ASL), could provide an alternative to phase contrast for visualizing in-plane flow patterns within the aorta and branch vessels. MAIN BODY: The study was IRB-approved and subjects provided consent. Breath-hold cine FISS and bSSFP were acquired using similar imaging parameters. There was no significant difference in biplane left ventricular ejection fraction or cardiac image quality between the two techniques. Compared with cine bSSFP, cine FISS demonstrated a marked decrease in fat signal which improved conspicuity of the coronary arteries, while suppression of through-plane flow artifact on thin-slice cine FISS images improved visualization of the aortic valve. Banding artifacts in the subcutaneous tissues were reduced. In healthy subjects, dynamic flow patterns were well visualized in the aorta, coronary and renal arteries using cine FISS ASL, even when the slice was substantially thicker than the vessel diameter. CONCLUSION: Cine FISS demonstrates several benefits for cardiovascular imaging compared with cine bSSFP, including better suppression of fat signal and reduced artifacts from through-plane flow and off-resonance effects. The main drawback is a slight (~ 20%) decrease in temporal resolution. In addition, preliminary results suggest that cine FISS ASL provides a potential alternative to phase contrast techniques for in-plane flow quantification, while enabling an efficient, visually-appealing, semi-projective display of blood flow patterns throughout the course of an artery and its branches. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (10.1186/s12968-018-0433-3) contains supplementary material, which is available to authorized users.
format Online
Article
Text
id pubmed-5819298
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-58192982018-02-21 Cardiovascular cine imaging and flow evaluation using Fast Interrupted Steady-State (FISS) magnetic resonance Edelman, Robert R. Serhal, Ali Pursnani, Amit Pang, Jianing Koktzoglou, Ioannis J Cardiovasc Magn Reson Technical Notes BACKGROUND: Existing cine imaging techniques rely on balanced steady-state free precession (bSSFP) or spoiled gradient-echo readouts, each of which has limitations. For instance, with bSSFP, artifacts occur from rapid through-plane flow and off-resonance effects. We hypothesized that a prototype cine technique, radial fast interrupted steady-state (FISS), could overcome these limitations. The technique was compared with standard cine bSSFP for cardiac function, coronary artery conspicuity, and aortic valve morphology. Given its advantageous properties, we further hypothesized that the cine FISS technique, in combination with arterial spin labeling (ASL), could provide an alternative to phase contrast for visualizing in-plane flow patterns within the aorta and branch vessels. MAIN BODY: The study was IRB-approved and subjects provided consent. Breath-hold cine FISS and bSSFP were acquired using similar imaging parameters. There was no significant difference in biplane left ventricular ejection fraction or cardiac image quality between the two techniques. Compared with cine bSSFP, cine FISS demonstrated a marked decrease in fat signal which improved conspicuity of the coronary arteries, while suppression of through-plane flow artifact on thin-slice cine FISS images improved visualization of the aortic valve. Banding artifacts in the subcutaneous tissues were reduced. In healthy subjects, dynamic flow patterns were well visualized in the aorta, coronary and renal arteries using cine FISS ASL, even when the slice was substantially thicker than the vessel diameter. CONCLUSION: Cine FISS demonstrates several benefits for cardiovascular imaging compared with cine bSSFP, including better suppression of fat signal and reduced artifacts from through-plane flow and off-resonance effects. The main drawback is a slight (~ 20%) decrease in temporal resolution. In addition, preliminary results suggest that cine FISS ASL provides a potential alternative to phase contrast techniques for in-plane flow quantification, while enabling an efficient, visually-appealing, semi-projective display of blood flow patterns throughout the course of an artery and its branches. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (10.1186/s12968-018-0433-3) contains supplementary material, which is available to authorized users. BioMed Central 2018-02-19 /pmc/articles/PMC5819298/ /pubmed/29458384 http://dx.doi.org/10.1186/s12968-018-0433-3 Text en © The Author(s). 2018 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Technical Notes
Edelman, Robert R.
Serhal, Ali
Pursnani, Amit
Pang, Jianing
Koktzoglou, Ioannis
Cardiovascular cine imaging and flow evaluation using Fast Interrupted Steady-State (FISS) magnetic resonance
title Cardiovascular cine imaging and flow evaluation using Fast Interrupted Steady-State (FISS) magnetic resonance
title_full Cardiovascular cine imaging and flow evaluation using Fast Interrupted Steady-State (FISS) magnetic resonance
title_fullStr Cardiovascular cine imaging and flow evaluation using Fast Interrupted Steady-State (FISS) magnetic resonance
title_full_unstemmed Cardiovascular cine imaging and flow evaluation using Fast Interrupted Steady-State (FISS) magnetic resonance
title_short Cardiovascular cine imaging and flow evaluation using Fast Interrupted Steady-State (FISS) magnetic resonance
title_sort cardiovascular cine imaging and flow evaluation using fast interrupted steady-state (fiss) magnetic resonance
topic Technical Notes
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5819298/
https://www.ncbi.nlm.nih.gov/pubmed/29458384
http://dx.doi.org/10.1186/s12968-018-0433-3
work_keys_str_mv AT edelmanrobertr cardiovascularcineimagingandflowevaluationusingfastinterruptedsteadystatefissmagneticresonance
AT serhalali cardiovascularcineimagingandflowevaluationusingfastinterruptedsteadystatefissmagneticresonance
AT pursnaniamit cardiovascularcineimagingandflowevaluationusingfastinterruptedsteadystatefissmagneticresonance
AT pangjianing cardiovascularcineimagingandflowevaluationusingfastinterruptedsteadystatefissmagneticresonance
AT koktzoglouioannis cardiovascularcineimagingandflowevaluationusingfastinterruptedsteadystatefissmagneticresonance